Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 7,174 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

Simple view, for homeowners: top picks by size and what each rating measures →

Xcel EnergyData as of updated · sources

Share of models
52.7%
Qualifying models
7,174
Qualifying certifications
197,833
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F12,514 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+39 above13 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4013
1.40 to under 1.5081
1.50 to under 1.60190
1.60 to under 1.70389
1.70 to under 1.801,291
1.80 to under 1.902,581
1.90 to under 2.001,532
2.00 to under 2.102,675
2.10 to under 2.201,457
2.20 to under 2.30883
2.30 to under 2.40548
2.40 to under 2.50284
2.50 to under 2.60246
2.60 to under 2.70139
2.70 to under 2.8081
2.80 to under 2.9052
2.90 to under 3.0033
3.00 and above39
Baseline: median2.00
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F12,433 rated models · median 72%64% of rated models reach 70% on this rating alone.
+59 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%29
35 to under 40%340
40 to under 45%483
45 to under 50%574
50 to under 55%704
55 to under 60%666
60 to under 65%782
65 to under 70%892
70 to under 75%2,697
75 to under 80%1,230
80 to under 85%910
85 to under 90%410
90 to under 95%798
95 to under 100%623
100 to under 105%825
105 to under 110%148
110 to under 115%151
115 to under 120%23
120 to under 125%38
125% and above59
Baseline: median72%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER213,615 rated models · median 18.1At least 72% of rated models reach 15.2 (the lowest path) on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.028
13.0 to under 13.5910
13.5 to under 14.0372
14.0 to under 14.51,115
14.5 to under 15.0198
15.0 to under 15.51,131
15.5 to under 16.0305
16.0 to under 16.5625
16.5 to under 17.0221
17.0 to under 17.5982
17.5 to under 18.0245
18.0 to under 18.5808
18.5 to under 19.0403
19.0 to under 19.5868
19.5 to under 20.0194
20.0 to under 20.51,156
20.5 to under 21.0179
21.0 to under 21.5851
21.5 to under 22.0172
22.0 to under 22.5571
22.5 to under 23.0220
23.0 to under 23.5729
23.5 to under 24.0120
24.0 to under 24.5340
24.5 to under 25.0157
25.0 to under 25.5302
25.5 to under 26.081
26.0 to under 26.544
26.5 to under 27.019
27.0 to under 27.569
27.5 to under 28.023
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.023
30.0 to under 30.523
30.5 and above54
Baseline: median18.1
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER213,614 rated models · median 11.597% of rated models reach 9 (the lowest path) on this rating alone.
+66 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5112
8.5 to under 9.0248
9.0 to under 9.5805
9.5 to under 10.01,039
10.0 to under 10.5975
10.5 to under 11.01,516
11.0 to under 11.51,966
11.5 to under 12.01,967
12.0 to under 12.52,024
12.5 to under 13.0985
13.0 to under 13.5988
13.5 to under 14.0242
14.0 to under 14.5299
14.5 to under 15.0123
15.0 to under 15.5189
15.5 to under 16.06
16.0 to under 16.537
16.5 to under 17.023
17.0 and above66
Baseline: median11.5
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons60.7% · 3,292 of 5,427
2 tons59.4% · 1,152 of 1,941
2.5 to 3 tons50.4% · 1,483 of 2,942
3.5 to 4.5 tons42.2% · 1,195 of 2,834
5 tons and up10.9% · 52 of 475

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted32.2%2,070 / 6,438
Non-ducted61.3%2,978 / 4,861
Ducted and non-ducted91.6%2,126 / 2,320

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree584 of 72980.1%
Midea387 of 55569.7%
Carrier246 of 84629.1%
TCL138 of 19271.9%
BlueRidge132 of 19468%
Daikin125 of 41030.5%
AUX124 of 18965.6%
Lennox121 of 34135.5%
Ephoca120 of 38231.4%
Innova120 of 38231.4%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 6 of 287
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
126ACIQ-K09Z-HP115BACiQwith ductless indoor unit ACIQ-K09W-W-HP115BACIQ1 ton9,000 Btu/h · Non-ducted1.8673%9.519.0CEE 25CEE 26Xcel2217606035
127ACIQ-K09Z-HP230BACiQwith ductless indoor unit ACIQ-K09W-W-HP230BACIQ1 ton9,000 Btu/h · Non-ducted1.8974%10.020.0CEE 25CEE 26Xcel2217606036
128ACIQ-K12Z-32-HP115BACiQwith ductless indoor unit ACIQ-K12W-BL-32-HP115BACIQ1 ton12,000 Btu/h · Non-ducted1.8073%10.020.0Xcel2218157784
129ACIQ-K12Z-32-HP230BACiQwith ductless indoor unit ACIQ-K12W-BL-32-HP230BACIQ1 ton12,000 Btu/h · Non-ducted1.8073%10.020.0Xcel2218157785
130ACIQ-K12Z-HP115BACiQwith ductless indoor unit ACIQ-K12W-W-HP115BACIQ1 ton12,000 Btu/h · Non-ducted1.7975%9.520.0CEE 25CEE 26Xcel2217606039
131ACIQ-K12Z-HP230BACiQwith ductless indoor unit ACIQ-K12W-W-HP230BACIQ1 ton12,000 Btu/h · Non-ducted1.8076%9.520.0CEE 25CEE 26Xcel2217606040
132B5H0V24*K*AAA*ACIQ · Deluxe 20 VS Heat Pumpwith ducted air handler FCMA5X24L0B*+WALLCONACIQ2 tons23,400 Btu/h · Ducted2.0470%9.017.5CEE 25CEE 26XcelES CC358218356241
133B5H0V36*K*AAA*ACIQ · Deluxe 20 VS Heat Pumpwith ducted air handler FCMA5B60L0D*+WALLCONACIQ3 tons35,400 Btu/h · Ducted2.0472%9.519.5CEE 25CEE 26XcelES CC741218356238
134B5H0V48*K*AAA*ACIQ · Deluxe 20 VS Heat Pumpwith ducted air handler FCMA5B60L0D*+WALLCONACIQ4 tons46,500 Btu/h · Ducted2.2070%9.519.5CEE 25CEE 26XcelES CC354218355418
135B5H0V60*K*AAA*ACIQ · Deluxe 20 VS Heat Pumpwith indoor coil EVM5X60M21A*+WALLCON and furnace *80CSU0401712BACIQ4.5 tons56,000 Btu/h · Ducted2.1572%8.118.0CEE 25CEE 26XcelES CC172218355767
136B5H3V24*K*AAA*ACIQ · Deluxe 23 VS Heat Pumpwith indoor coil EVM5X25M17A*+WALLCON and furnace *80CSU0401712BACIQ2 tons23,200 Btu/h · Ducted2.1081%9.522.0CEE 25CEE 26XcelES CC419218628932
137B5H3V36*K*AAA*ACIQ · Deluxe 23 VS Heat Pumpwith ducted air handler FCMA5B60L0D*+WALLCONACIQ3 tons35,000 Btu/h · Ducted2.1075%9.522.0CEE 25CEE 26XcelES CC514218628754
138B5H3V48*K*AAA*ACIQ · Deluxe 23 VS Heat Pumpwith ducted air handler FCMA5B48L0C*+WALLCONACIQ4 tons45,500 Btu/h · Ducted2.0074%9.522.0CEE 25CEE 26XcelES CC182218629866
139B5H3V60*K*AAA*ACIQ · Deluxe 23 VS Heat Pumpwith ducted air handler FCMA5B60L0D*+WALLCONACIQ5 tons58,000 Btu/h · Ducted2.1874%9.020.0CEE 25CEE 26XcelES CC152218628756
140ES-18Z-M3CACIQ · ES SeriesACIQ1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.3174%9.922.6CEE 25CEE 26XcelES CC3216032378
141ES-27Z-M4CACIQ · ES SeriesACIQ2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.525.0CEE 25CEE 26XcelES CC3216032379
142ES-36Z-M5CACIQ · ES SeriesACIQ3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.524.0CEE 25CEE 26XcelES CC3216032382
143ES-48Z-M6CACIQ · ES SeriesACIQ4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1081%10.620.4CEE 25CEE 26XcelES CC3216032386
144H5H0V24*K*AAA*ACIQ · Deluxe 20 VS Heat Pumpwith ducted air handler FCMA5X24L0B*+WALLCONACIQ2 tons23,400 Btu/h · Ducted2.0470%9.017.5CEE 25CEE 26XcelES CC410216632845
145H5H0V36*K*AAA*ACIQ · Deluxe 20 VS Heat Pumpwith ducted air handler FCMA5B60L0D*+WALLCONACIQ3 tons35,400 Btu/h · Ducted2.0472%9.519.5CEE 25CEE 26XcelES CC831216633393
146H5H0V48*K*AAA*ACIQ · Deluxe 20 VS Heat Pumpwith ducted air handler FCMA5B60L0D*+WALLCONACIQ4 tons46,500 Btu/h · Ducted2.2070%9.519.5CEE 25CEE 26XcelES CC396216633870
147H5H0V60*K*AAA*ACIQ · Deluxe 20 VS Heat Pumpwith indoor coil EVM5X60M21A*+WALLCON and furnace *80CSU0401712BACIQ4.5 tons56,000 Btu/h · Ducted2.1572%8.118.0CEE 25CEE 26XcelES CC190216634616
148H5H3V36*K*AAA*ACIQ · Deluxe 23 VS Heat Pumpwith indoor coil EVD5X60M21A*+WALLCON and furnace *95CSU1002122BACIQ3 tons35,600 Btu/h · Ducted2.1475%9.022.0CEE 25CEE 26XcelES CC577216635748
149H5H3V48*K*AAA*ACIQ · Deluxe 23 VS Heat Pumpwith indoor coil EA*5X48M21A*+WALLCON and furnace *80CSU1002120AACIQ3.5 tons43,500 Btu/h · Ducted2.0076%9.520.5CEE 25CEE 26XcelES CC332216635479
150H5H3V60*K*AAA*ACIQ · Deluxe 23 VS Heat Pumpwith indoor coil EA*5X61M21A*+WALLCON and furnace *80CTL0701716BACIQ4.5 tons56,000 Btu/h · Ducted2.1075%8.518.0CEE 25CEE 26XcelES CC180216635247

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter