Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 6,515 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

New to heat pump ratings? The Simple view explains them in plain words →

Xcel EnergyData as of updated · sources

Share of models
52.8%
Qualifying models
6,515
Qualifying certifications
189,411
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F11,219 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+40 above12 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4012
1.40 to under 1.5079
1.50 to under 1.60176
1.60 to under 1.70335
1.70 to under 1.801,180
1.80 to under 1.902,238
1.90 to under 2.001,350
2.00 to under 2.102,426
2.10 to under 2.201,325
2.20 to under 2.30778
2.30 to under 2.40511
2.40 to under 2.50260
2.50 to under 2.60215
2.60 to under 2.70132
2.70 to under 2.8080
2.80 to under 2.9051
2.90 to under 3.0031
3.00 and above40
Baseline: median2.00
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F11,154 rated models · median 72%65% of rated models reach 70% on this rating alone.
+40 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%28
35 to under 40%337
40 to under 45%467
45 to under 50%519
50 to under 55%566
55 to under 60%526
60 to under 65%684
65 to under 70%763
70 to under 75%2,401
75 to under 80%1,156
80 to under 85%798
85 to under 90%375
90 to under 95%720
95 to under 100%580
100 to under 105%757
105 to under 110%151
110 to under 115%148
115 to under 120%27
120 to under 125%41
125 to under 130%19
130% and above40
Baseline: median72%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER212,328 rated models · median 18.0At least 71% of rated models reach 15.2 (the lowest path) on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.014
13.0 to under 13.5900
13.5 to under 14.0338
14.0 to under 14.51,002
14.5 to under 15.0192
15.0 to under 15.51,101
15.5 to under 16.0284
16.0 to under 16.5624
16.5 to under 17.0188
17.0 to under 17.5849
17.5 to under 18.0214
18.0 to under 18.5680
18.5 to under 19.0393
19.0 to under 19.5745
19.5 to under 20.0182
20.0 to under 20.5917
20.5 to under 21.0162
21.0 to under 21.5783
21.5 to under 22.0162
22.0 to under 22.5508
22.5 to under 23.0197
23.0 to under 23.5661
23.5 to under 24.0111
24.0 to under 24.5294
24.5 to under 25.0151
25.0 to under 25.5286
25.5 to under 26.075
26.0 to under 26.539
26.5 to under 27.018
27.0 to under 27.560
27.5 to under 28.022
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.022
30.0 to under 30.523
30.5 and above54
Baseline: median18.0
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER212,324 rated models · median 11.597% of rated models reach 9 (the lowest path) on this rating alone.
+31 above2 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.02
8.0 to under 8.595
8.5 to under 9.0214
9.0 to under 9.5702
9.5 to under 10.0831
10.0 to under 10.5881
10.5 to under 11.01,359
11.0 to under 11.51,678
11.5 to under 12.01,904
12.0 to under 12.51,869
12.5 to under 13.0951
13.0 to under 13.5914
13.5 to under 14.0232
14.0 to under 14.5274
14.5 to under 15.0114
15.0 to under 15.5179
15.5 to under 16.05
16.0 to under 16.531
16.5 to under 17.023
17.0 to under 17.535
17.5 and above31
Baseline: median11.5
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons61.6% · 2,905 of 4,715
2 tons60.8% · 1,062 of 1,748
2.5–3 tons50.3% · 1,369 of 2,724
3.5–4.5 tons42.1% · 1,130 of 2,687
5 tons and up10.7% · 49 of 458

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted31.9%1,933 / 6,056
Non-ducted63%2,573 / 4,087
Ducted and non-ducted91.8%2,009 / 2,189

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree574 of 71780.1%
Midea381 of 54669.8%
Carrier223 of 81627.3%
BlueRidge131 of 19268.2%
TCL128 of 17772.3%
Lennox121 of 33735.9%
Ephoca120 of 38231.4%
Daikin117 of 39429.7%
Rheem115 of 34133.7%
Hisense110 of 16168.3%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 97 of 261
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
2401TSHG24E2S20NAR45OGeneralluxGenerallux2 tons22,000 Btu/h · Ducted and non-ducted2.0074%10.019.0CEE 25CEE 26Xcel3216765727
2402GNS12HCH23R454OGENERALLUX STAR · HYPER HEATwith ductless indoor unit GNS12HCH23R454IGENERALLUX STAR1 ton12,000 Btu/h · Non-ducted2.0092%10.023.0CEE 25CEE 26Xcel1215887346
2403GNS18HCH21R32OGENERALLUX STAR · HYPER HEATwith ductless indoor unit GNS18HCH21R32IGENERALLUX STAR1.5 tons18,000 Btu/h · Non-ducted2.4976%9.821.0CEE 25CEE 26Xcel1215887344
2404GNS18HCH21R454OGENERALLUX STAR · HYPER HEATwith ductless indoor unit GNS18HCH21R454IGENERALLUX STAR1.5 tons18,000 Btu/h · Non-ducted1.90100%10.021.0CEE 25CEE 26Xcel1215887347
2405GNS24HCH20R32OGENERALLUX STARwith ductless indoor unit GNS24HCH20R32IGENERALLUX STAR2 tons24,000 Btu/h · Non-ducted1.9077%8.519.5CEE 25CEE 26Xcel1215887345
2406GNS24HCH23R454OGENERALLUX STAR · HYPER HEATwith ductless indoor unit GNS24HCH23R454IGENERALLUX STAR2 tons24,000 Btu/h · Non-ducted1.8483%9.522.5CEE 25CEE 26Xcel1215887348
2407A7CP21V24P-**AAC PRO · A7CP21V Serieswith ducted air handler 7AH2AV24PXCGree2 tons23,600 Btu/h · Ducted2.3075%10.020.5CEE 25CEE 26XcelES CC121217465740
2408A7CP21V36P-**AAC PRO · A7CP21V Serieswith indoor coil 7EH30BX-**+TDR and furnace A80UH2E090B12Gree3 tons33,200 Btu/h · Ducted2.4673%9.019.0CEE 25CEE 26XcelES CC161217466086
2409A7CP21V48P-**AAC PRO · A7CP21V Serieswith ducted air handler 7AH1AE60PX-Gree4 tons47,000 Btu/h · Ducted2.2079%9.019.5CEE 25CEE 26XcelES CC126217465940
2410A7CP21V60P-**AAC PRO · A7CP21V Serieswith indoor coil 7E[C,U]60CX-**+TDR and furnace A80US2V090C20Gree4.5 tons55,000 Btu/h · Ducted2.1865%8.520.5CEE 25CEE 26XcelES CC84217465776
2411AIRY09HP230V1AOGREE · Airywith ductless indoor unit AIRY09HP230V1AHGree1 ton9,100 Btu/h · Non-ducted2.11108%11.230.0CEE 25CEE 26CEE AdvXcelDOEES CC1217175296
2412AIRY12HP230V1AOGREE · Airywith ductless indoor unit AIRY12HP230V1AHGree1 ton12,000 Btu/h · Non-ducted2.00100%10.029.5CEE 25CEE 26XcelES CC1217175297
2413AIRY18HP230V1AOGREE · Airywith ductless indoor unit AIRY18HP230V1AHGree1.5 tons18,000 Btu/h · Non-ducted1.8097%10.027.5CEE 25CEE 26XcelES CC1217175298
2414AIRY24HP230V1AOGREE · Airywith ductless indoor unit AIRY24HP230V1AHGree2 tons22,000 Btu/h · Non-ducted1.80100%10.027.0CEE 25CEE 26XcelES CC1217175299
2415BH719M36P-**AAC PRO · BH719M Serieswith indoor coil BC748DCT-**+TDR and furnace B97DR902E4CGree3 tons34,800 Btu/h · Ducted2.2047%8.516.5CEE 25CEE 26Xcel299217504768
2416CHM09HP230V1R32AOGREE · Charmowith ductless indoor unit CHM09HP230V1R32AHGree1 ton9,100 Btu/h · Non-ducted1.9476%8.820.5CEE 25CEE 26XcelES CC1217607995
2417CHM12HP230V1R32AOGREE · Charmowith ductless indoor unit CHM12HP230V1R32AHGree1 ton12,000 Btu/h · Non-ducted1.7576%8.519.0XcelES CC1217607996
2418CHM18HP230V1R32AOGREE · Charmowith ductless indoor unit CHM18HP230V1R32AHGree1.5 tons18,000 Btu/h · Non-ducted1.8571%8.520.0CEE 25CEE 26XcelES CC1217607997
2419CHM30HP230V1R32AOGREEwith ductless indoor unit CHM30HP230V1R32AHGree2.5 tons30,000 Btu/h · Non-ducted1.8077%9.022.0CEE 25CEE 26Xcel1217607999
2420CHM36HP230V1R32AOGREE · Charmowith ductless indoor unit CHM36HP230V1R32AHGree3 tons33,600 Btu/h · Non-ducted1.8072%8.521.0CEE 25CEE 26XcelES CC1217608000
2421ENV09HP115V1R32AOGREE · Cliviawith ductless indoor unit ENV09HP115V1R32AHGree1 ton9,100 Btu/h · Non-ducted1.8392%10.527.0CEE 25CEE 26XcelES CC1214779341
2422ENV09HP230V1R32AOGREE · Ductedwith ducted air handler DUC09HP230V1R32AHGree1 ton9,100 Btu/h · Ducted and non-ducted2.1490%9.222.0CEE 25CEE 26XcelES CC6215413812
2423ENV12HP115V1R32AOGREE · Cliviawith ductless indoor unit ENV12HP115V1R32AHGree1 ton12,000 Btu/h · Non-ducted1.9579%9.524.5CEE 25CEE 26XcelES CC1214779343
2424ENV12HP230V1R32AOGREE · Cliviawith ductless indoor unit ENV12HP230V1R32AHGree1 ton12,000 Btu/h · Ducted and non-ducted1.9592%9.524.5CEE 25CEE 26XcelES CC6214779344
2425ENV18HP230V1R32AOGREE · Cliviawith ductless indoor unit ENV18HP230V1R32AHGree1.5 tons18,000 Btu/h · Ducted and non-ducted1.9081%9.024.5CEE 25CEE 26XcelES CC8214777850

Explore qualifying models by COP at 5°F