Boltic heat pump efficiency: 5 outdoor models compared

Boltic has 5 heat pump outdoor models certified with this refrigerant group, in 5 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Boltic makes. Boltic has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
5
AHRI certifications
5
Efficiency index
32%
Typical model vs same-size, same-type peers (5 models)
Meet CEE 2025
40%
2 models

How Boltic compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
Boltic against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of Boltic’s own modelsBoltic is strongest on COP at 5°F (its typical model beats 59% of comparable models) and weakest on capacity retention at 5°F (19%).
  • Boltic
  • Middle half of its models
  • Other ranked manufacturers
Boltic

Source: AHRI Directory, NEEP · as of

Average peer percentile of Boltic’s models
RatingBeats comparable modelsRankRaw median
Efficiency index5 models scored32%Not ranked—
COP at 5°F5 models scored59%Not ranked1.99
Capacity retention at 5°F5 models scored19%Not ranked67%
HSPF25 models scored27%Not ranked9.0
SEER25 models scored35%Not ranked20.2
EER25 models scored25%Not ranked10.0
Heating capacity at 5°F5 models scored31%Not ranked11,500 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
Boltic’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • Boltic (median, middle 50%, 10th–90th)
  • All models of the group
Non-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Non-ducted, up to 1.5 tons335%47%28%46%
Non-ducted, 2 tons129%76%24%16%
Non-ducted, 2.5–3 tons127%76%27%19%

Every Boltic model in the market

Boltic’s 5 models with a known size and duct type, over the shape of the whole catalog.
Boltic models by size and ratingColoured: Boltic · grey shapes: all 14,508 models · lines: catalog medians by size
  • Boltic models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 5 boltic models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 14,508 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8261.641.711.751.852.24
Ducted, 1 ton4071.801.902.052.412.45
Ducted, 1.5 tons9921.751.862.002.172.40
Ducted, 2 tons9991.751.862.002.182.30
Ducted, 2.5 tons1,0401.701.802.002.102.36
Ducted, 3 tons6961.801.902.002.102.42
Ducted, 3.5 tons8641.701.802.002.102.46
Ducted, 4 tons7271.801.862.002.122.40
Ducted, 4.5 tons6901.701.801.902.102.20
Ducted, 5 tons861.892.002.102.102.10
Non-ducted, 0.5 tons1,1861.751.801.902.002.22
Non-ducted, 1 ton1,3431.801.801.992.102.21
Non-ducted, 1.5 tons1,2611.801.802.002.102.31
Non-ducted, 2 tons7611.801.982.002.102.30
Non-ducted, 2.5 tons4031.801.852.002.002.10
Non-ducted, 3 tons4731.901.982.002.032.20
Non-ducted, 3.5 tons2802.002.002.002.052.10
Non-ducted, 4 tons2041.962.002.052.102.11
Non-ducted, 4.5 tons781.901.911.952.012.01
Non-ducted, 5 tons841.992.002.052.202.20

Source: AHRI Directory · as of

Top Boltic models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 2 Boltic cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
187A24KODUBolticwith ductless indoor unit 87A24KIDU2 tons24,000 Btu/h · Non-ducted71%2.119.017,00018.5Xcel1215864289Non-ducted, 2 tons45.1
287A9KODUBolticwith ductless indoor unit 87A9KIDU1 ton9,000 Btu/h · Non-ducted70%1.959.07,00021.5CEE 25CEE 26Xcel1215864286Non-ducted, up to 1.5 tons34.7

All-around best

Top 5 Boltic models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
187A9KODUBolticwith ductless indoor unit 87A9KIDU1 ton9,000 Btu/h · Non-ducted70%1.959.021.512.5CEE 25CEE 26Xcel1215864286Non-ducted, up to 1.5 tons44.934.755.134.7
287A18KODUBolticwith ductless indoor unit 87A18KIDU1.5 tons18,000 Btu/h · Non-ducted61%1.999.120.211.5CEE 25CEE 261215864288Non-ducted, up to 1.5 tons34.333.335.4Not a pick
387A24KODUBolticwith ductless indoor unit 87A24KIDU2 tons24,000 Btu/h · Non-ducted71%2.119.018.59.6Xcel1215864289Non-ducted, 2 tons29.245.113.345.1
487A36KODUBolticwith ductless indoor unit 87A36KIDU3 tons36,000 Btu/h · Non-ducted67%2.029.119.59.3None1215864290Non-ducted, 2.5–3 tons26.640.812.5Not a pick
587A12KODUBolticwith ductless indoor unit 87A12KIDU1 ton12,000 Btu/h · Non-ducted58%1.858.721.310.0None1215864287Non-ducted, up to 1.5 tons26.420.332.6Not a pick

Best model on each rating

Boltic’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°F87A24KODU2.11Non-ducted, 2 tons76%215864289
Capacity retention at 5°F87A24KODU71%Non-ducted, 2 tons37%215864289
HSPF287A18KODU9.1Non-ducted, up to 1.5 tons34%215864288
SEER287A9KODU21.5Non-ducted, up to 1.5 tons51%215864286
EER287A9KODU12.5Non-ducted, up to 1.5 tons56%215864286
Heating capacity at 5°F87A18KODU11,500 Btu/hNon-ducted, up to 1.5 tons63%215864288

All 5 Boltic models in Explore

Boltic size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
Boltic: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Non-ducted, up to 1.5 tons34.7(50 is the typical model of its size class)87A9KODUwith ductless indoor unit 87A9KIDU1 of 3 models qualify · AHRI 21586428644.9(50 is the typical model of its size class)87A9KODUwith ductless indoor unit 87A9KIDU3 of 3 models have all five ratings · AHRI 215864286
Non-ducted, 2 tons45.1(50 is the typical model of its size class)87A24KODUwith ductless indoor unit 87A24KIDU1 of 1 models qualify · AHRI 21586428929.2(50 is the typical model of its size class)87A24KODUwith ductless indoor unit 87A24KIDU1 of 1 models have all five ratings · AHRI 215864289
Non-ducted, 2.5–3 tonsNone on this board (0 of 1 models qualify)26.6(50 is the typical model of its size class)87A36KODUwith ductless indoor unit 87A36KIDU1 of 1 models have all five ratings · AHRI 215864290

All-around board, every manufacturer

Newest Boltic certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified Boltic outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
87A36KODUBolticwith ductless indoor unit 87A36KIDU3 tons36,000 Btu/h · Non-ducted2.0267%9.119.5None1215864290
87A24KODUBolticwith ductless indoor unit 87A24KIDU2 tons24,000 Btu/h · Non-ducted2.1171%9.018.5Xcel1215864289
87A18KODUBolticwith ductless indoor unit 87A18KIDU1.5 tons18,000 Btu/h · Non-ducted1.9961%9.120.2CEE 25CEE 261215864288
87A12KODUBolticwith ductless indoor unit 87A12KIDU1 ton12,000 Btu/h · Non-ducted1.8558%8.721.3None1215864287
87A9KODUBolticwith ductless indoor unit 87A9KIDU1 ton9,000 Btu/h · Non-ducted1.9570%9.021.5CEE 25CEE 26Xcel1215864286

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare Boltic

Manufacturers of a similar size, side by side.

Boltic includes these brand names as listed in AHRI: Boltic. Standards are checked against published thresholds; program rules beyond ratings are not checked.