Skip to content

Airdach vs BROCK heat pumps

Measured against models of the same size and duct type, Airdach scores higher on 5 of the 6 ratings. Airdach has 29 outdoor models, BROCK has 36 outdoor models. Airdach and BROCK have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Airdach and BROCK on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Airdach scores higher on 5 of the 6 ratings.
  • Airdach
  • BROCK
  • Other ranked manufacturers
AirdachBROCK

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingAirdachBROCK
Efficiency index40% (higher)median —35% (higher)median —
COP at 5°F48% (higher)median 1.9441% (higher)median 1.80
Capacity retention at 5°F34% (higher)median 71%13% (higher)median 41%
HSPF228% (higher)median 7.524% (higher)median 6.7
SEER229% (higher)median 14.324% (higher)median 13.4
EER249%median 11.464%median 11.1
Heating capacity at 5°F31% (higher)median 15,700 Btu/h17% (higher)median 17,000 Btu/h
Outdoor models2936
AHRI certifications453,770

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardAirdachBROCK
CEE 2025 Tier 1 (Split ASHP)24.1%7 models19.4%7 models
CEE 2026 Tier 1 (Split ASHP)24.1%7 models11.1%4 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)31%9 models0%0 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 4 groups where both have models
  • Airdach
  • BROCK
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeAirdachBROCK
Ducted, up to 1.5 tons2 · index —2 · index 45%
Ducted, 2 tons3 · index 36%4 · index 35%
Ducted, 2.5–3 tons7 · index 48%11 · index 35%
Ducted, 3.5–4.5 tons10 · index 54%17 · index 31%
Ducted, 5 tons and upNone2 · index 61%
Non-ducted, up to 1.5 tons5 · index 30%None
Non-ducted, 2 tons1 · index 25%None
Non-ducted, 2.5–3 tons1 · index 30%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeAirdachCold-climate score, best modelBROCKCold-climate score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 2 models qualify)None on this board (0 of 2 models qualify)
Ducted, 2 tonsNone on this board (0 of 3 models qualify)None on this board (0 of 4 models qualify)
Ducted, 2.5–3 tons59.2(50 is the typical model of its size class)A3TH36180OV1DGwith ducted air handler A3DH36000OE1DT1 of 7 models qualify · AHRI 218797045None on this board (0 of 11 models qualify)
Ducted, 3.5–4.5 tons69.8(50 is the typical model of its size class)A3TH60180OV1DGwith ducted air handler A3DH60000OE1DT1 of 10 models qualify · AHRI 218797046None on this board (0 of 17 models qualify)
Ducted, 5 tons and upNo models in this size classNone on this board (0 of 2 models qualify)
Non-ducted, up to 1.5 tons41.6(50 is the typical model of its size class)ACSH0920VR1-D3with ductless indoor unit AIWH0900VR1-D35 of 5 models qualify · AHRI 217101992No models in this size class
Non-ducted, 2 tons13.5(50 is the typical model of its size class)ACSH2419VR1-D3with ductless indoor unit AIWH2400VR1-D31 of 1 models qualify · AHRI 217101991No models in this size class
Non-ducted, 2.5–3 tons22.3(50 is the typical model of its size class)ACSH3621VR1-D3with ductless indoor unit AIWH3600VR1-D31 of 1 models qualify · AHRI 217101990No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeAirdachAll-around score, best modelBROCKAll-around score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 2 models have all five ratings)48.3(50 is the typical model of its size class)PH5SAN519**AA*with indoor coil CAA**1917AM and furnace PG92MSAA42060B2 of 2 models have all five ratings · AHRI 217702474
Ducted, 2 tons35.7(50 is the typical model of its size class)A4TH24152MN1DLwith ducted air handler A4DH2400ME1DT1 of 3 models have all five ratings · AHRI 21833177260.6(50 is the typical model of its size class) (higher)PH8TAN524**AA*with indoor coil CAA**3721AM and furnace PG80MSUA48060B4 of 4 models have all five ratings · AHRI 215647876
Ducted, 2.5–3 tons57.4(50 is the typical model of its size class)A3TH36180OV1DGwith ducted air handler A3DH36000OE1DT3 of 7 models have all five ratings · AHRI 21879704566.7(50 is the typical model of its size class) (higher)PH8TAN536**AA*with ducted air handler PF5TNBD60L11 of 11 models have all five ratings · AHRI 215628948
Ducted, 3.5–4.5 tons59.5(50 is the typical model of its size class)A3TH60180OV1DGwith ducted air handler A3DH60000OE1DT4 of 10 models have all five ratings · AHRI 21879704672.7(50 is the typical model of its size class) (higher)PH8TAN548**AA*with ducted air handler QFVA5D6021X16 of 16 models have all five ratings · AHRI 218695444
Ducted, 5 tons and upNo models in this size class80.2(50 is the typical model of its size class)PH8TAN560**AA*with ducted air handler PF5TNBD60L3 of 3 models have all five ratings · AHRI 215560743
Non-ducted, up to 1.5 tons44.9(50 is the typical model of its size class)ACSH0920VR1-D3with ductless indoor unit AIWH0900VR1-D35 of 5 models have all five ratings · AHRI 217101992No models in this size class
Non-ducted, 2 tons24.5(50 is the typical model of its size class)ACSH2419VR1-D3with ductless indoor unit AIWH2400VR1-D31 of 1 models have all five ratings · AHRI 217101991No models in this size class
Non-ducted, 2.5–3 tons30.4(50 is the typical model of its size class)ACSH3621VR1-D3with ductless indoor unit AIWH3600VR1-D31 of 1 models have all five ratings · AHRI 217101990No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingAirdachBROCK
COP at 5°Fbeats 86% · 2.30A4TH42152MN1DLDucted, 3.5–4.5 tonsbeats 92% · 2.48PH8TAN536**AA*Ducted, 2.5–3 tons
Capacity retention at 5°Fbeats 55% · 73%A3TH36180OV1DGDucted, 2.5–3 tonsbeats 41% · 52%PH5SAN560**AA*Also listed as PH5SAP560**AADucted, 5 tons and up
HSPF2beats 64% · 8.8A3TH60180OV1DGDucted, 3.5–4.5 tonsbeats 58% · 8.5PH8TAN548**AA*Ducted, 3.5–4.5 tons
SEER2beats 76% · 18.0A3TH60180OV1DGDucted, 3.5–4.5 tonsbeats 81% · 17.5PH8TAN560**AA*Ducted, 5 tons and up
EER2beats 83% · 12.0A4TH48152MN1DLDucted, 3.5–4.5 tonsbeats 99% · 13.5PH8TAN548**AA*Ducted, 3.5–4.5 tons
Heating capacity at 5°Fbeats 69% · 12,100 Btu/hACSH1820VR1-D3Non-ducted, up to 1.5 tonsbeats 44% · 8,600 Btu/hPH5SAN518**AA*Ducted, up to 1.5 tons