Skip to content

Friedrich vs Midea heat pumps

Measured against models of the same size and duct type, Midea scores higher on 6 of the 6 ratings. Friedrich has 192 outdoor models, Midea has 555 outdoor models.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Friedrich and Midea on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Midea scores higher on 6 of the 6 ratings.
  • Friedrich
  • Midea
  • Other ranked manufacturers
FriedrichMidea

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingFriedrichMidea
Efficiency index40%median — · 28th ranked60%median — · 7th ranked
COP at 5°F46%median 1.99 · 22nd ranked60%median 2.00 · 8th ranked
Capacity retention at 5°F36%median 51% · 27th ranked57%median 74% · 10th ranked
HSPF232%median 7.5 · 28th ranked66%median 9.5 · 6th ranked
SEER235%median 15.2 · 28th ranked61%median 19.5 · 5th ranked
EER238%median 10.6 · 29th ranked55%median 11.7 · 13th ranked
Heating capacity at 5°F34%median 17,400 Btu/h · 28th ranked60%median 20,000 Btu/h · 10th ranked
Outdoor models192555
AHRI certifications6,8006,788

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardFriedrichMidea
CEE 2025 Tier 1 (Split ASHP)28.1%54 models75.3%418 models
CEE 2026 Tier 1 (Split ASHP)25%48 models74.2%412 models
CEE Advanced Tier (Split ASHP)0.5%1 models3.4%19 models
Xcel Energy Colorado cold-climate ASHP (2025)22.4%43 models69.7%387 models
DOE Cold Climate Heat Pump Challenge0.5%1 models3.4%19 models
ENERGY STAR Cold Climate21.9%42 models64%355 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 9 groups where both have models
  • Friedrich
  • Midea
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeFriedrichMidea
Ducted, up to 1.5 tons20 · index 31%80 · index 75%
Ducted, 2 tons23 · index 32%57 · index 62%
Ducted, 2.5 to 3 tons47 · index 36%122 · index 61%
Ducted, 3.5 to 4.5 tons59 · index 41%110 · index 63%
Ducted, 5 tons and up22 · index 36%22 · index 63%
Non-ducted, up to 1.5 tons20 · index 57%185 · index 57%
Non-ducted, 2 tons5 · index 52%50 · index 53%
Non-ducted, 2.5 to 3 tons4 · index 48%94 · index 56%
Non-ducted, 3.5 to 4.5 tons2 · index 47%64 · index 49%
Non-ducted, 5 tons and upNone15 · index 45%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeFriedrichCold-climate score, best modelMideaCold-climate score, best model
Ducted, up to 1.5 tons73.8(50 is the typical model of its size class)FPHFR24A3Dwith ducted air handler FPHFA18A3D6 of 22 models qualify · AHRI 21750565793.7(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as MDV MOX230-06HFN10-M1X; also listed as D5CSHAH06AAK71 of 81 models qualify · AHRI 215324042
Ducted, 2 tons70.9(50 is the typical model of its size class)RD17AY24AJVCwith ducted air handler FRH2VY2417STACN5 of 21 models qualify · AHRI 21912594885.8(50 is the typical model of its size class) (higher)37MAHAQ24AA3with ducted air handler 45MBDAQ24XH3Also sold as MDV MOD30-24HFN10-M1X; also listed as D5CSHAH24AAK49 of 54 models qualify · AHRI 215324061
Ducted, 2.5 to 3 tons78.4(50 is the typical model of its size class)RD18AY36AJVCwith indoor coil RCFY3621MTANM and furnace FR801V0504A17UHN7 of 47 models qualify · AHRI 21689124690.3(50 is the typical model of its size class) (higher)M4OD31-27HFN8-M1XD92 of 126 models qualify · AHRI 218083250
Ducted, 3.5 to 4.5 tons83.9(50 is the typical model of its size class)FPHFR48A3Dwith ducted air handler FPHFA48A3D11 of 59 models qualify · AHRI 21750887283.9(50 is the typical model of its size class)MOVA-60HDN10-M20Gwith ducted air handler MVME60C2MN10TAAlso listed as MOVC-60HDN10-M20G91 of 106 models qualify · AHRI 214814477
Ducted, 5 tons and up78.1(50 is the typical model of its size class) (higher)FRP17AY60AJVCwith indoor coil RCFY6024STANM and furnace FR801V1255A24UHN1 of 22 models qualify · AHRI 21832811067.0(50 is the typical model of its size class)MDV-V60WMN10TAlso listed as MDV-V60WMN10T(B)6 of 24 models qualify · AHRI 216021062
Non-ducted, up to 1.5 tons83.4(50 is the typical model of its size class)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D16 of 20 models qualify · AHRI 21423240897.7(50 is the typical model of its size class) (higher)MOX230-06HFN10-M1with ductless indoor unit MSEPB-06HRFN10-M1125 of 185 models qualify · AHRI 215865890
Non-ducted, 2 tons76.9(50 is the typical model of its size class)FPHFR24A3Dwith ductless indoor unit FPHFC24A3D5 of 5 models qualify · AHRI 21662615590.1(50 is the typical model of its size class) (higher)37MAHAQ24AA3with ductless indoor unit 45MBCAQ24XA3Also sold as MDV MOD30-24HFN10-M1X; also listed as D5CSHAH24AAK44 of 50 models qualify · AHRI 215324059
Non-ducted, 2.5 to 3 tons59.0(50 is the typical model of its size class)FPHFR36A3Dwith ductless indoor unit FPHSC36A3D3 of 4 models qualify · AHRI 21669960889.4(50 is the typical model of its size class) (higher)37MBHAQ36AA3with ductless indoor unit 45MCFAQ36XA3Also sold as MDV MOX630-36HFN10-M2X; also listed as D5CLHAH36AAK78 of 94 models qualify · AHRI 215324087
Non-ducted, 3.5 to 4.5 tons49.8(50 is the typical model of its size class)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models qualify · AHRI 21669960975.6(50 is the typical model of its size class) (higher)D5CMHAH48FAKAlso sold as MDV M6OE31-48HFN10-M1XD, MDV M6OE31-48HFN10-M1X; also listed as 37MGHAQ48FA357 of 64 models qualify · AHRI 215357417
Non-ducted, 5 tons and upNo models in this size class52.1(50 is the typical model of its size class)MDV-V60WMN10TAlso listed as MDV-V60WMN10T(B)3 of 15 models qualify · AHRI 216021081

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeFriedrichAll-around score, best modelMideaAll-around score, best model
Ducted, up to 1.5 tons68.5(50 is the typical model of its size class)FPHFR24A3Dwith ducted air handler FPHFA18A3D21 of 21 models have all five ratings · AHRI 21750565795.7(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as MDV MOX230-06HFN10-M1X; also listed as D5CSHAH06AAK83 of 83 models have all five ratings · AHRI 215324042
Ducted, 2 tons75.5(50 is the typical model of its size class)FRP19AY24AJVCwith ducted air handler FRHMVY3621MEACA21 of 21 models have all five ratings · AHRI 21573959390.0(50 is the typical model of its size class) (higher)MOD30-24HFN10-M1Hwith ducted air handler MSEPD-24HRFN10-M1H55 of 55 models have all five ratings · AHRI 217998293
Ducted, 2.5 to 3 tons84.9(50 is the typical model of its size class)FRP19AY36AJVCwith ducted air handler FRHMVY3621MEACA34 of 47 models have all five ratings · AHRI 21558444091.8(50 is the typical model of its size class) (higher)M4OD31-27HFN8-M1XD121 of 121 models have all five ratings · AHRI 218083250
Ducted, 3.5 to 4.5 tons84.3(50 is the typical model of its size class)FRP19AY48AJVCwith ducted air handler FRHMVY4821SEACA37 of 56 models have all five ratings · AHRI 21558444186.0(50 is the typical model of its size class) (higher)D5CMRAH48FAKAlso sold as MDV M6OE30-48HFN10-M1D, MDV M6OE30-48HFN10-M1; also listed as 37MGRAQ48FA3110 of 110 models have all five ratings · AHRI 215357445
Ducted, 5 tons and up70.6(50 is the typical model of its size class) (higher)FRP17AY60AJVCwith ducted air handler RH2TY6024STANN16 of 26 models have all five ratings · AHRI 21832840670.5(50 is the typical model of its size class)MRD-60HWD1N10-M18GAlso listed as MRD-60HWD1N10-M18GB22 of 22 models have all five ratings · AHRI 215894250
Non-ducted, up to 1.5 tons85.1(50 is the typical model of its size class)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D20 of 20 models have all five ratings · AHRI 21423240896.9(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ductless indoor unit D5MAHAQ06XA3Also sold as MDV MOX230-06HFN10-M1X; also listed as D5CSHAH06AAK176 of 185 models have all five ratings · AHRI 215323786
Non-ducted, 2 tons63.6(50 is the typical model of its size class)FPHSR24A3Bwith ductless indoor unit FAHFW24A3AAlso listed as FPHSR24A3D5 of 5 models have all five ratings · AHRI 21409182089.4(50 is the typical model of its size class) (higher)37MARAQ24AA3with ductless indoor unit D5MAHAQ24XA3Also sold as MDV MOD30-24HFN10-M1; also listed as D5CSRAH24AAK46 of 50 models have all five ratings · AHRI 215323796
Non-ducted, 2.5 to 3 tons64.9(50 is the typical model of its size class)FPHMR27A3D4 of 4 models have all five ratings · AHRI 21579283989.4(50 is the typical model of its size class) (higher)M4OD31-27HFN8-M1XD93 of 94 models have all five ratings · AHRI 218083249
Non-ducted, 3.5 to 4.5 tons49.4(50 is the typical model of its size class)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models have all five ratings · AHRI 21669960976.6(50 is the typical model of its size class) (higher)D5CMHAH48FAKAlso sold as MDV M6OE31-48HFN10-M1XD, MDV M6OE31-48HFN10-M1X; also listed as 37MGHAQ48FA363 of 64 models have all five ratings · AHRI 215357415
Non-ducted, 5 tons and upNo models in this size class61.8(50 is the typical model of its size class)D5CMRAH55FAKAlso sold as MDV M6OE30-60HFN10-M1D, MDV M6OE30-60HFN10-M1; also listed as 37MGRAQ55FA315 of 15 models have all five ratings · AHRI 215357450

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingFriedrichMidea
COP at 5°Fbeats 97% · 2.40FSHSR18B3BAlso listed as FSHSR18B3DNon-ducted, up to 1.5 tonsbeats 99% · 2.5137MARAQ12AA3Also sold as MDV MOX230-12HFN10-M1; also listed as D5CSRAH12AAKNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 100% · 133%FPHFR09A3DDucted, up to 1.5 tonsbeats 100% · 150%37MPRAQ06AA3Also sold as MDV MOX430-06HFN10-M1HNon-ducted, up to 1.5 tons
HSPF2beats 91% · 9.5FRP17AY60AJVCDucted, 5 tons and upbeats 100% · 15.637MPRAQ06AA3Also sold as MDV MOX430-06HFN10-M1HNon-ducted, up to 1.5 tons
SEER2beats 98% · 21.0FRP19AY36AJVCDucted, 2.5 to 3 tonsbeats 100% · 27.0MOX430-15HFN10-M1HDucted, up to 1.5 tons
EER2beats 96% · 13.0RD18AY36AJVCDucted, 2.5 to 3 tonsbeats 100% · 18.1MOX230-06HFN10-M1Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 96% · 18,600 Btu/hRD18AY24AJVCDucted, up to 1.5 tonsbeats 100% · 55,000 Btu/hMOVA-60HDN10-M20GAlso listed as MOVC-60HDN10-M20GDucted, 3.5 to 4.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Friedrich vs Midea: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Friedrich (median, middle 50%)
  • Midea (median, middle 50%)
Heating capacity, % of its 47°F maximum71%66%COP at maximum capacity2.002.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
Friedrich: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Friedrich, 47°F44100%100%100%100%100%
Friedrich, 17°F4460%65%68%84%92%
Friedrich, 5°F4457%62%71%74%85%
Friedrich: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Friedrich, 47°F442.82.93.083.213.46
Friedrich, 17°F442.072.22.42.52.51
Friedrich, 5°F441.891.922.092.1
Midea: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Midea, 47°F502100%100%100%100%100%
Midea, 17°F50264%68%73%81%85%
Midea, 5°F50257%62%66%77%82%
Midea: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Midea, 47°F5022.883.13.243.493.61
Midea, 17°F5022.12.222.32.492.62
Midea, 5°F5021.851.9922.112.31

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter