Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Friedrich vs Midea heat pumps
Measured against models of the same size and duct type, Midea scores higher on 6 of the 6 ratings. Friedrich has 188 outdoor models, Midea has 546 outdoor models.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Friedrich
- Midea
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Friedrich | Midea |
|---|---|---|
| Efficiency index | 39%median — · 28th ranked | 59%median — · 7th ranked |
| COP at 5°F | 46%median 1.99 · 22nd ranked | 59%median 2.00 · 9th ranked |
| Capacity retention at 5°F | 36%median 52% · 26th ranked | 56%median 74% · 11th ranked |
| HSPF2 | 31%median 7.5 · 28th ranked | 66%median 9.5 · 7th ranked |
| SEER2 | 34%median 15.2 · 28th ranked | 61%median 19.5 · 6th ranked |
| EER2 | 37%median 10.6 · 27th ranked | 54%median 11.7 · 15th ranked |
| Heating capacity at 5°F | 35%median 17,000 Btu/h · 28th ranked | 59%median 20,400 Btu/h · 10th ranked |
| Outdoor models | 188 | 546 |
| AHRI certifications | 6,657 | 5,356 |
Share of models meeting each standard
| Standard | Friedrich | Midea |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 26.6%50 models | 75.5%412 models |
| CEE 2026 Tier 1 (Split ASHP) | 23.9%45 models | 73.8%403 models |
| CEE Advanced Tier (Split ASHP) | 0.5%1 models | 3.1%17 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 21.3%40 models | 69.8%381 models |
| DOE Cold Climate Heat Pump Challenge | 0.5%1 models | 3.1%17 models |
| ENERGY STAR Cold Climate | 22.3%42 models | 63.9%349 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Friedrich
- Midea
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Friedrich | Midea |
|---|---|---|
| Ducted, up to 1.5 tons | 21 · index 30% | 79 · index 73% |
| Ducted, 2 tons | 21 · index 31% | 57 · index 62% |
| Ducted, 2.5–3 tons | 46 · index 37% | 121 · index 61% |
| Ducted, 3.5–4.5 tons | 58 · index 41% | 109 · index 63% |
| Ducted, 5 tons and up | 21 · index 31% | 22 · index 63% |
| Non-ducted, up to 1.5 tons | 20 · index 55% | 179 · index 55% |
| Non-ducted, 2 tons | 5 · index 50% | 50 · index 51% |
| Non-ducted, 2.5–3 tons | 4 · index 47% | 92 · index 55% |
| Non-ducted, 3.5–4.5 tons | 2 · index 47% | 64 · index 50% |
| Non-ducted, 5 tons and up | None | 15 · index 44% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | FriedrichCold-climate score, best model | MideaCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 73.0(50 is the typical model of its size class)FPHFR24A3Dwith ducted air handler FPHFA18A3D5 of 21 models qualify · AHRI 217505657 | 93.5(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as MDV MOX230-06HFN10-M1X; also listed as D5CSHAH06AAK70 of 80 models qualify · AHRI 215324042 |
| Ducted, 2 tons | 70.3(50 is the typical model of its size class)RD18AY24AJVCwith indoor coil RCFY2417STANM and furnace FR801V0504A17UHU4 of 21 models qualify · AHRI 217176021 | 86.4(50 is the typical model of its size class) (higher)MOU-B24H-2with ducted air handler MIU-B24D-249 of 54 models qualify · AHRI 217022110 |
| Ducted, 2.5–3 tons | 78.1(50 is the typical model of its size class)RD18AY36AJVCwith indoor coil RCFY3621MTANM and furnace FR801V0504A17UHN6 of 46 models qualify · AHRI 216891246 | 88.8(50 is the typical model of its size class) (higher)MOE30-36HFN10-M3Xwith ducted air handler MVBDM-36HWFN10-WC391 of 125 models qualify · AHRI 216967947 |
| Ducted, 3.5–4.5 tons | 83.9(50 is the typical model of its size class)FPHFR48A3Dwith ducted air handler FPHFA48A3D8 of 57 models qualify · AHRI 217508872 | 83.9(50 is the typical model of its size class)MOVA-60HDN10-M20Gwith ducted air handler MVME60C2MN10TAAlso listed as MOVC-60HDN10-M20G91 of 106 models qualify · AHRI 214814477 |
| Ducted, 5 tons and up | 77.3(50 is the typical model of its size class) (higher)FRP17AY60AJVCwith indoor coil RCFY6024STANM and furnace FR802V1255A24UHN1 of 22 models qualify · AHRI 218328124 | 65.9(50 is the typical model of its size class)MDV-V60WMN10T5 of 23 models qualify · AHRI 216021062 |
| Non-ducted, up to 1.5 tons | 82.4(50 is the typical model of its size class)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D16 of 20 models qualify · AHRI 214232408 | 97.5(50 is the typical model of its size class) (higher)MOX230-06HFN10-M1with ductless indoor unit MSEPB-06HRFN10-M1121 of 179 models qualify · AHRI 215865890 |
| Non-ducted, 2 tons | 76.3(50 is the typical model of its size class)FPHFR24A3Dwith ductless indoor unit FPHFC24A3D5 of 5 models qualify · AHRI 216626155 | 89.4(50 is the typical model of its size class) (higher)37MAHAQ24AA3with ductless indoor unit 45MBCAQ24XA3Also sold as MDV MOD30-24HFN10-M1X; also listed as D5CSHAH24AAK44 of 50 models qualify · AHRI 215324059 |
| Non-ducted, 2.5–3 tons | 58.2(50 is the typical model of its size class)FPHFR36A3Dwith ductless indoor unit FPHSC36A3D3 of 4 models qualify · AHRI 216699608 | 89.8(50 is the typical model of its size class) (higher)MOU-B36LH-2with ductless indoor unit MIU-B36LF-276 of 92 models qualify · AHRI 217022114 |
| Non-ducted, 3.5–4.5 tons | 49.7(50 is the typical model of its size class)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models qualify · AHRI 216699609 | 75.5(50 is the typical model of its size class) (higher)D5CMHAH48FAKAlso sold as MDV M6OE31-48HFN10-M1XD, MDV M6OE31-48HFN10-M1X; also listed as 37MGHAQ48FA357 of 64 models qualify · AHRI 215357417 |
| Non-ducted, 5 tons and up | No models in this size class | 50.6(50 is the typical model of its size class)MDV-V60WMN10TAlso listed as MDV-V60WMN10T(B)3 of 15 models qualify · AHRI 216021081 |
All-around best
| Size and duct type | FriedrichAll-around score, best model | MideaAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 67.4(50 is the typical model of its size class)FPHFR24A3Dwith ducted air handler FPHFA18A3D20 of 20 models have all five ratings · AHRI 217505657 | 95.6(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as MDV MOX230-06HFN10-M1X; also listed as D5CSHAH06AAK80 of 80 models have all five ratings · AHRI 215324042 |
| Ducted, 2 tons | 75.1(50 is the typical model of its size class)FRP19AY24AJVCwith indoor coil RCFY2421HEAAM and furnace FR951V0603A17M421 of 21 models have all five ratings · AHRI 216551633 | 89.9(50 is the typical model of its size class) (higher)MOD30-24HFN10-M1Hwith ducted air handler MSEPD-24HRFN10-M1H57 of 57 models have all five ratings · AHRI 217998293 |
| Ducted, 2.5–3 tons | 84.1(50 is the typical model of its size class)RD18AY36AJVCwith ducted air handler RH2VY3621MTACN30 of 46 models have all five ratings · AHRI 216613170 | 85.5(50 is the typical model of its size class) (higher)D5CMHAH30EAKAlso sold as MDV M5OX631-30HFN10-M1XD; also listed as 37MGHAQ30EA3120 of 120 models have all five ratings · AHRI 215357410 |
| Ducted, 3.5–4.5 tons | 84.1(50 is the typical model of its size class)FRP19AY48AJVCwith indoor coil RCFY4821SEAAM and furnace FR802V0754A17UH32 of 54 models have all five ratings · AHRI 216551827 | 85.7(50 is the typical model of its size class) (higher)D5CMRAH48FAKAlso sold as MDV M6OE30-48HFN10-M1D, MDV M6OE30-48HFN10-M1; also listed as 37MGRAQ48FA3109 of 109 models have all five ratings · AHRI 215357445 |
| Ducted, 5 tons and up | 70.3(50 is the typical model of its size class) (higher)FRP17AY60AJVCwith ducted air handler RH2TY6024STANN14 of 26 models have all five ratings · AHRI 218328406 | 70.1(50 is the typical model of its size class)MRD-60HWD1N10-M18GAlso listed as MRD-60HWD1N10-M18GB22 of 22 models have all five ratings · AHRI 215894250 |
| Non-ducted, up to 1.5 tons | 83.9(50 is the typical model of its size class)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D20 of 20 models have all five ratings · AHRI 214232408 | 96.5(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ductless indoor unit D5MAHAQ06XA3Also sold as MDV MOX230-06HFN10-M1X; also listed as D5CSHAH06AAK170 of 179 models have all five ratings · AHRI 215323786 |
| Non-ducted, 2 tons | 61.6(50 is the typical model of its size class)FPHSR24A3Bwith ductless indoor unit FAHFW24A3AAlso listed as FPHSR24A3D5 of 5 models have all five ratings · AHRI 214091820 | 88.5(50 is the typical model of its size class) (higher)37MARAQ24AA3with ductless indoor unit D5MAHAQ24XA3Also sold as MDV MOD30-24HFN10-M1; also listed as D5CSRAH24AAK46 of 50 models have all five ratings · AHRI 215323796 |
| Non-ducted, 2.5–3 tons | 64.2(50 is the typical model of its size class)FPHMR27A3D4 of 4 models have all five ratings · AHRI 215792839 | 85.8(50 is the typical model of its size class) (higher)D5CMHAH30EAKAlso sold as MDV M5OX631-30HFN10-M1XD; also listed as 37MGHAQ30EA391 of 92 models have all five ratings · AHRI 215357409 |
| Non-ducted, 3.5–4.5 tons | 49.6(50 is the typical model of its size class)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models have all five ratings · AHRI 216699609 | 76.7(50 is the typical model of its size class) (higher)D5CMHAH48FAKAlso sold as MDV M6OE31-48HFN10-M1XD, MDV M6OE31-48HFN10-M1X; also listed as 37MGHAQ48FA363 of 64 models have all five ratings · AHRI 215357415 |
| Non-ducted, 5 tons and up | No models in this size class | 61.3(50 is the typical model of its size class)D5CMRAH55FAKAlso sold as MDV M6OE30-60HFN10-M1D, MDV M6OE30-60HFN10-M1; also listed as 37MGRAQ55FA315 of 15 models have all five ratings · AHRI 215357450 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Friedrich | Midea |
|---|---|---|
| COP at 5°F | beats 98% · 2.61WFPU17Y243DDucted, up to 1.5 tons | beats 99% · 2.5137MARAQ12AA3Also sold as MDV MOX230-12HFN10-M1; also listed as D5CSRAH12AAKNon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 100% · 133%FPHFR09A3DDucted, up to 1.5 tons | beats 100% · 150%37MPRAQ06AA3Also sold as MDV MOX430-06HFN10-M1HNon-ducted, up to 1.5 tons |
| HSPF2 | beats 86% · 10.0FRP19AY60AJVCDucted, 3.5–4.5 tons | beats 100% · 15.637MPRAQ06AA3Also sold as MDV MOX430-06HFN10-M1HNon-ducted, up to 1.5 tons |
| SEER2 | beats 98% · 21.0FRP19AY36AJVCDucted, 2.5–3 tons | beats 100% · 27.0MOX430-15HFN10-M1HDucted, up to 1.5 tons |
| EER2 | beats 96% · 13.0RD18AY36AJVCDucted, 2.5–3 tons | beats 100% · 18.1MOX230-06HFN10-M1Non-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 96% · 18,600 Btu/hRD18AY24AJVCDucted, up to 1.5 tons | beats 100% · 55,000 Btu/hMOVA-60HDN10-M20GAlso listed as MOVC-60HDN10-M20GDucted, 3.5–4.5 tons |