Kepler vs TCL heat pumps
Measured against models of the same size and duct type, Kepler scores higher on 6 of the 6 ratings. Kepler has 45 outdoor models, TCL has 192 outdoor models. Kepler and TCL have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Kepler
- TCL
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Kepler | TCL |
|---|---|---|
| Efficiency index | 63% (higher)median — | 50% (higher)median — |
| COP at 5°F | 59% (higher)median 2.00 | 36% (higher)median 1.89 |
| Capacity retention at 5°F | 63% (higher)median 81% | 52% (higher)median 75% |
| HSPF2 | 74% (higher)median 9.7 | 53% (higher)median 9.5 |
| SEER2 | 65% (higher)median 20.0 | 59% (higher)median 20.0 |
| EER2 | 58% (higher)median 11.7 | 41% (higher)median 11.2 |
| Heating capacity at 5°F | 65% (higher)median 21,600 Btu/h | 52% (higher)median 17,000 Btu/h |
| Outdoor models | 45 | 192 |
| AHRI certifications | 169 | 701 |
Share of models meeting each standard
| Standard | Kepler | TCL |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 86.7%39 models | 75%144 models |
| CEE 2026 Tier 1 (Split ASHP) | 84.4%38 models | 75%144 models |
| CEE Advanced Tier (Split ASHP) | 2.2%1 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 80%36 models | 71.9%138 models |
| DOE Cold Climate Heat Pump Challenge | 2.2%1 models | 0%0 models |
| ENERGY STAR Cold Climate | 75.6%34 models | 64.6%124 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Kepler
- TCL
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Kepler | TCL |
|---|---|---|
| Ducted, up to 1.5 tons | 11 · index 76% | 12 · index 59% |
| Ducted, 2 tons | 5 · index 67% | 12 · index 49% |
| Ducted, 2.5 to 3 tons | 9 · index 60% | 21 · index 58% |
| Ducted, 3.5 to 4.5 tons | 10 · index 59% | 22 · index 50% |
| Ducted, 5 tons and up | 1 · index 63% | None |
| Non-ducted, up to 1.5 tons | 14 · index 64% | 95 · index 50% |
| Non-ducted, 2 tons | 3 · index 67% | 20 · index 43% |
| Non-ducted, 2.5 to 3 tons | 8 · index 53% | 29 · index 48% |
| Non-ducted, 3.5 to 4.5 tons | 4 · index 60% | 12 · index 46% |
| Non-ducted, 5 tons and up | 1 · index 59% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | KeplerCold-climate score, best model | TCLCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 93.7(50 is the typical model of its size class) (higher)ODUMOX230-06HFN10-M1Xwith ducted air handler IDUMTI-06HWFN10-M1-D10 of 11 models qualify · AHRI 218857674 | 68.6(50 is the typical model of its size class)THH18TEI2NAG0F24with ducted air handler THH18IEI2NAG0F24Also listed as H18TDHXPC12 of 12 models qualify · AHRI 218083091 |
| Ducted, 2 tons | 85.8(50 is the typical model of its size class) (higher)ODUMOD30-24HFN10-M1Xwith ducted air handler IDUMTJ-24HWFN10-M1-D5 of 5 models qualify · AHRI 218857661 | 69.6(50 is the typical model of its size class)H24TDHXPCwith ducted air handler H24FAHUDE11 of 12 models qualify · AHRI 218332483 |
| Ducted, 2.5 to 3 tons | 83.5(50 is the typical model of its size class) (higher)ODUMOX630-36HFN10-M2Xwith ducted air handler IDUMTJ-36HWFN10-M2-D8 of 9 models qualify · AHRI 218856688 | 67.2(50 is the typical model of its size class)THH30TEI2NAG0F24with ducted air handler THH30IEI2NAG0F24Also listed as H30TDHXPC19 of 21 models qualify · AHRI 218082877 |
| Ducted, 3.5 to 4.5 tons | 82.6(50 is the typical model of its size class) (higher)ODUM6OE31-48HFN10-M1XD-D10 of 10 models qualify · AHRI 218853768 | 69.4(50 is the typical model of its size class)H48SDH20XQCwith ducted air handler H48APH20UDEAlso listed as THH48HDI2NAJ0H2622 of 22 models qualify · AHRI 218453819 |
| Ducted, 5 tons and up | None on this board (0 of 1 models qualify) | No models in this size class |
| Non-ducted, up to 1.5 tons | 97.0(50 is the typical model of its size class) (higher)ODUMOX230-06HFN10-M1Xwith ductless indoor unit IDUMSEPB-06HRFN10-M1-D11 of 14 models qualify · AHRI 218851004 | 72.4(50 is the typical model of its size class)TMH18HEI2NAS0U25Also listed as H18FMHD3XPC, TMH18HEI2NAS0U2571 of 95 models qualify · AHRI 218028413 |
| Non-ducted, 2 tons | 90.1(50 is the typical model of its size class) (higher)ODUMOD30-24HFN10-M1Xwith ductless indoor unit IDUMCD-24HRFN10-M1-D3 of 3 models qualify · AHRI 218857649 | 63.4(50 is the typical model of its size class)TSH24HDI2NAN0T26with ductless indoor unit TSH24IDI2NAN0T26Also listed as H24SBH23XQC12 of 21 models qualify · AHRI 218082864 |
| Non-ducted, 2.5 to 3 tons | 78.3(50 is the typical model of its size class) (higher)ODUM5OX631-36HFN10-M1XD-D6 of 8 models qualify · AHRI 218853766 | 68.7(50 is the typical model of its size class)TMH27HEI2NAS0U25Also listed as H27FMHD4XPC, TMH27HEI2NAS0U2519 of 28 models qualify · AHRI 218028414 |
| Non-ducted, 3.5 to 4.5 tons | 73.6(50 is the typical model of its size class) (higher)ODUM6OE31-48HFN10-M1XD-D4 of 4 models qualify · AHRI 218853769 | 48.5(50 is the typical model of its size class)TMH48HEI2NAS0U2511 of 12 models qualify · AHRI 218028416 |
| Non-ducted, 5 tons and up | None on this board (0 of 1 models qualify) | No models in this size class |
All-around best
| Size and duct type | KeplerAll-around score, best model | TCLAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 95.1(50 is the typical model of its size class) (higher)ODUMOX230-06HFN10-M1Xwith ducted air handler IDUMTI-06HWFN10-M1-D11 of 11 models have all five ratings · AHRI 218857674 | 73.5(50 is the typical model of its size class)TMH18HEI2NAS0U25*Also listed as H18FMHD3XPC12 of 12 models have all five ratings · AHRI 218625046 |
| Ducted, 2 tons | 78.9(50 is the typical model of its size class) (higher)ODUMOD30-24HFN10-M1with ducted air handler IDUMTJ-24HWFN10-M1-D5 of 5 models have all five ratings · AHRI 218857656 | 70.1(50 is the typical model of its size class)H24SDH20XQCwith ducted air handler H24APH20UDEAlso listed as THH24HDI2NAJ0H2614 of 14 models have all five ratings · AHRI 218453815 |
| Ducted, 2.5 to 3 tons | 83.9(50 is the typical model of its size class) (higher)ODUM5OX631-36HFN10-M1XD-D9 of 9 models have all five ratings · AHRI 218853765 | 80.6(50 is the typical model of its size class)TMH27HEI2NAS0U25*Also listed as H27FMHD4XPC19 of 19 models have all five ratings · AHRI 218625047 |
| Ducted, 3.5 to 4.5 tons | 85.3(50 is the typical model of its size class) (higher)ODUM6OE30-48HFN10-M1D-D10 of 10 models have all five ratings · AHRI 218853753 | 66.2(50 is the typical model of its size class)TMH42HDI2NAO0U25Also listed as TMH42HDI2NAO0U2522 of 22 models have all five ratings · AHRI 218467786 |
| Ducted, 5 tons and up | 63.2(50 is the typical model of its size class)ODUM6OE30-60HFN10-M1D-D1 of 1 models have all five ratings · AHRI 218853756 | No models in this size class |
| Non-ducted, up to 1.5 tons | 96.6(50 is the typical model of its size class) (higher)ODUMOX230-06HFN10-M1Xwith ductless indoor unit IDUMSEPB-06HRFN10-M1-D14 of 14 models have all five ratings · AHRI 218851004 | 83.7(50 is the typical model of its size class)TMH18HEI2NAS0U25Also listed as H18FMHD3XPC, TMH18HEI2NAS0U2585 of 96 models have all five ratings · AHRI 218028413 |
| Non-ducted, 2 tons | 87.8(50 is the typical model of its size class) (higher)ODUMOD30-24HFN10-M1with ductless indoor unit IDUMSEPD-24HRFN10-M1-D3 of 3 models have all five ratings · AHRI 218851003 | 67.0(50 is the typical model of its size class)TSH24HDI2NAN0T26with ductless indoor unit TSH24IDI2NAN0T26Also listed as H24SBH23XQC18 of 19 models have all five ratings · AHRI 218082864 |
| Non-ducted, 2.5 to 3 tons | 78.8(50 is the typical model of its size class)ODUM5OX631-36HFN10-M1XD-D8 of 8 models have all five ratings · AHRI 218853764 | 83.4(50 is the typical model of its size class) (higher)TMH27HEI2NAS0U25Also listed as H27FMHD4XPC, TMH27HEI2NAS0U2528 of 29 models have all five ratings · AHRI 218028414 |
| Non-ducted, 3.5 to 4.5 tons | 75.4(50 is the typical model of its size class) (higher)ODUM6OE31-48HFN10-M1XD-D4 of 4 models have all five ratings · AHRI 218853767 | 70.2(50 is the typical model of its size class)TMH48HEI2NAS0U2512 of 12 models have all five ratings · AHRI 218028416 |
| Non-ducted, 5 tons and up | 59.0(50 is the typical model of its size class)ODUM6OE30-60HFN10-M1D-D1 of 1 models have all five ratings · AHRI 218853755 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Kepler | TCL |
|---|---|---|
| COP at 5°F | beats 99% · 2.51ODUMOX230-12HFN10-M1Non-ducted, up to 1.5 tons | beats 88% · 2.25TSH24HDI2NAL0B25Also listed as H24SVH20XQCNon-ducted, 2 tons |
| Capacity retention at 5°F | beats 98% · 126%ODUMOX330-09HFN10-M1XNon-ducted, up to 1.5 tons | beats 99% · 125%H24TDHXPCDucted, 2 tons |
| HSPF2 | beats 99% · 14.8ODUMOX230-06HFN10-M1XNon-ducted, up to 1.5 tons | beats 96% · 10.5TMH36HEI2NAM5U24Also listed as H36FMH21XPCDucted, 2.5 to 3 tons |
| SEER2 | beats 97% · 25.0ODUM4OD30-27HFN10-M1D-DNon-ducted, 2.5 to 3 tons | beats 100% · 22.0TMH27HEI2NAS0U25*Also listed as H27FMHD4XPCDucted, 2.5 to 3 tons |
| EER2 | beats 99% · 18.0ODUMOX230-06HFN10-M1XNon-ducted, up to 1.5 tons | beats 97% · 14.0TMH27HEI2NAS0U25Also listed as H27FMHD4XPC, TMH27HEI2NAS0U25Non-ducted, 2.5 to 3 tons |
| Heating capacity at 5°F | beats 98% · 39,000 Btu/hODUMOX630-36HFN10-M3XDucted, 2.5 to 3 tons | beats 99% · 30,000 Btu/hH24TDHXPCDucted, 2 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- Kepler (median, middle 50%)
- TCL (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Kepler, 47°F | 45 | 100% | 100% | 100% | 100% | 100% |
| Kepler, 17°F | 45 | 69% | 73% | 76% | 81% | 86% |
| Kepler, 5°F | 45 | 59% | 64% | 71% | 79% | 82% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Kepler, 47°F | 45 | 2.84 | 3.06 | 3.2 | 3.46 | 3.72 |
| Kepler, 17°F | 45 | 2 | 2.14 | 2.32 | 2.51 | 2.61 |
| Kepler, 5°F | 45 | 1.85 | 1.9 | 2 | 2.1 | 2.36 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| TCL, 47°F | 110 | 100% | 100% | 100% | 100% | 100% |
| TCL, 17°F | 110 | 67% | 72% | 74% | 82% | 92% |
| TCL, 5°F | 110 | 58% | 65% | 70% | 72% | 77% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| TCL, 47°F | 110 | 2.5 | 2.8 | 3.01 | 3.5 | 3.71 |
| TCL, 17°F | 110 | 1.99 | 2.09 | 2.2 | 2.3 | 2.47 |
| TCL, 5°F | 110 | 1.8 | 1.8 | 1.9 | 2 | 2.03 |
Source: NEEP ccASHP list · as of