Both views use the same certified data. This device remembers your choice.
CEE 2025 Tier 1 (Split ASHP): 7,790 qualifying heat pumps
The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.
Simple view, for homeowners: top picks by size and what each rating measures →
Consortium for Energy EfficiencyData as of updated · sources
- Share of models
- 57.2%
- Qualifying models
- 7,790
- Qualifying certifications
- 238,391
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|---|
| Path A (heating-dominated) | ≥ 16 | ≥ 9.8 | ≥ 8.5 | ≥ 1.75 | ≥ 60% |
| Path B (cooling-dominated / dual fuel) | ≥ 16 | ≥ 11 | ≥ 8 | ≥ 1.75 | ≥ 45% |
Source: Consortium for Energy Efficiency
Where the thresholds fall
Every model's representative certification on each rating CEE 2025 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 13 |
| 1.40 to under 1.50 | 81 |
| 1.50 to under 1.60 | 190 |
| 1.60 to under 1.70 | 389 |
| 1.70 to under 1.80 | 1,291 |
| 1.80 to under 1.90 | 2,581 |
| 1.90 to under 2.00 | 1,532 |
| 2.00 to under 2.10 | 2,675 |
| 2.10 to under 2.20 | 1,457 |
| 2.20 to under 2.30 | 883 |
| 2.30 to under 2.40 | 548 |
| 2.40 to under 2.50 | 284 |
| 2.50 to under 2.60 | 246 |
| 2.60 to under 2.70 | 139 |
| 2.70 to under 2.80 | 81 |
| 2.80 to under 2.90 | 52 |
| 2.90 to under 3.00 | 33 |
| 3.00 and above | 39 |
| Baseline: median | 2.00 |
| Baseline: CEE 2025 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 51 |
| 30 to under 35% | 29 |
| 35 to under 40% | 340 |
| 40 to under 45% | 483 |
| 45 to under 50% | 574 |
| 50 to under 55% | 704 |
| 55 to under 60% | 666 |
| 60 to under 65% | 782 |
| 65 to under 70% | 892 |
| 70 to under 75% | 2,697 |
| 75 to under 80% | 1,230 |
| 80 to under 85% | 910 |
| 85 to under 90% | 410 |
| 90 to under 95% | 798 |
| 95 to under 100% | 623 |
| 100 to under 105% | 825 |
| 105 to under 110% | 148 |
| 110 to under 115% | 151 |
| 115 to under 120% | 23 |
| 120 to under 125% | 38 |
| 125% and above | 59 |
| Baseline: median | 72% |
| Baseline: Path B 45% | 45% |
| Baseline: Path A 60% | 60% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 43 |
| 6.5 to under 6.8 | 1,016 |
| 6.8 to under 7.0 | 69 |
| 7.0 to under 7.3 | 568 |
| 7.3 to under 7.5 | 18 |
| 7.5 to under 7.8 | 1,201 |
| 7.8 to under 8.0 | 382 |
| 8.0 to under 8.3 | 838 |
| 8.3 to under 8.5 | 188 |
| 8.5 to under 8.8 | 1,687 |
| 8.8 to under 9.0 | 198 |
| 9.0 to under 9.3 | 1,671 |
| 9.3 to under 9.5 | 142 |
| 9.5 to under 9.8 | 1,624 |
| 9.8 to under 10.0 | 312 |
| 10.0 to under 10.3 | 1,826 |
| 10.3 to under 10.5 | 237 |
| 10.5 to under 10.8 | 656 |
| 10.8 to under 11.0 | 82 |
| 11.0 to under 11.3 | 316 |
| 11.3 to under 11.5 | 60 |
| 11.5 to under 11.8 | 131 |
| 11.8 to under 12.0 | 21 |
| 12.0 to under 12.3 | 30 |
| 12.3 to under 12.5 | 2 |
| 12.5 to under 12.8 | 96 |
| 12.8 to under 13.0 | 1 |
| 13.0 to under 13.3 | 24 |
| 13.3 to under 13.5 | 10 |
| 13.5 to under 13.8 | 46 |
| 13.8 to under 14.0 | 37 |
| 14.0 and above | 63 |
| Baseline: median | 9.0 |
| Baseline: Path B 8 | 8.0 |
| Baseline: Path A 8.5 | 8.5 |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 12.5 | 54 |
| 12.5 to under 13.0 | 28 |
| 13.0 to under 13.5 | 910 |
| 13.5 to under 14.0 | 372 |
| 14.0 to under 14.5 | 1,115 |
| 14.5 to under 15.0 | 198 |
| 15.0 to under 15.5 | 1,131 |
| 15.5 to under 16.0 | 305 |
| 16.0 to under 16.5 | 625 |
| 16.5 to under 17.0 | 221 |
| 17.0 to under 17.5 | 982 |
| 17.5 to under 18.0 | 245 |
| 18.0 to under 18.5 | 808 |
| 18.5 to under 19.0 | 403 |
| 19.0 to under 19.5 | 868 |
| 19.5 to under 20.0 | 194 |
| 20.0 to under 20.5 | 1,156 |
| 20.5 to under 21.0 | 179 |
| 21.0 to under 21.5 | 851 |
| 21.5 to under 22.0 | 172 |
| 22.0 to under 22.5 | 571 |
| 22.5 to under 23.0 | 220 |
| 23.0 to under 23.5 | 729 |
| 23.5 to under 24.0 | 120 |
| 24.0 to under 24.5 | 340 |
| 24.5 to under 25.0 | 157 |
| 25.0 to under 25.5 | 302 |
| 25.5 to under 26.0 | 81 |
| 26.0 to under 26.5 | 44 |
| 26.5 to under 27.0 | 19 |
| 27.0 to under 27.5 | 69 |
| 27.5 to under 28.0 | 23 |
| 28.0 to under 28.5 | 7 |
| 28.5 to under 29.0 | 1 |
| 29.0 to under 29.5 | 15 |
| 29.5 to under 30.0 | 23 |
| 30.0 to under 30.5 | 23 |
| 30.5 and above | 54 |
| Baseline: median | 18.1 |
| Baseline: CEE 2025 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 4 |
| 8.0 to under 8.5 | 112 |
| 8.5 to under 9.0 | 248 |
| 9.0 to under 9.5 | 805 |
| 9.5 to under 10.0 | 1,039 |
| 10.0 to under 10.5 | 975 |
| 10.5 to under 11.0 | 1,516 |
| 11.0 to under 11.5 | 1,966 |
| 11.5 to under 12.0 | 1,967 |
| 12.0 to under 12.5 | 2,024 |
| 12.5 to under 13.0 | 985 |
| 13.0 to under 13.5 | 988 |
| 13.5 to under 14.0 | 242 |
| 14.0 to under 14.5 | 299 |
| 14.5 to under 15.0 | 123 |
| 15.0 to under 15.5 | 189 |
| 15.5 to under 16.0 | 6 |
| 16.0 to under 16.5 | 37 |
| 16.5 to under 17.0 | 23 |
| 17.0 and above | 66 |
| Baseline: median | 11.5 |
| Baseline: Path A 9.8 | 9.8 |
| Baseline: Path B 11 | 11.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons61.8% · 3,352 of 5,427
- 2 tons67.4% · 1,308 of 1,941
- 2.5 to 3 tons57.3% · 1,685 of 2,942
- 3.5 to 4.5 tons45.6% · 1,293 of 2,834
- 5 tons and up32% · 152 of 475
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 61.8% · 3,352 of 5,427 |
| 2 tons | 67.4% · 1,308 of 1,941 |
| 2.5 to 3 tons | 57.3% · 1,685 of 2,942 |
| 3.5 to 4.5 tons | 45.6% · 1,293 of 2,834 |
| 5 tons and up | 32% · 152 of 475 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 34.7% | 2,236 / 6,438 |
| Non-ducted | 67.9% | 3,299 / 4,861 |
| Ducted and non-ducted | 97.2% | 2,255 / 2,320 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 593 of 729 | 81.3% |
| Midea | 418 of 555 | 75.3% |
| Carrier | 354 of 846 | 41.8% |
| Daikin | 162 of 410 | 39.5% |
| Lennox | 147 of 341 | 43.1% |
| BlueRidge | 146 of 194 | 75.3% |
| TCL | 144 of 192 | 75% |
| Trane | 143 of 370 | 38.6% |
| Hisense | 134 of 168 | 79.8% |
| York | 130 of 239 | 54.4% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 70765HPL6024A1000A*Trane/American Standard · NV serieswith ducted air handler 5TEM7B02AC21SA | Trane/American Standard | 2 tons22,800 Btu/h · Ducted | 2.50 | 56% | 9.4 | 19.5 | CEE 25CEE 26 | 1 | 217456912 |
| 70775HPL9036A1000A*Trane/American Standard · P serieswith ducted air handler 5TEM9D04AC31SA | Trane/American Standard | 3 tons36,000 Btu/h · Ducted | 2.50 | 50% | 9.2 | 19.5 | CEE 25CEE 26 | 1 | 217497620 |
| 7078GUD18W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler GUD12AH2/E-D(U) | TRUENORTH | 1.5 tons17,000 Btu/h · Ducted | 2.00 | 100% | 9.0 | 18.0 | CEE 25CEE 26XcelES CC | 1 | 218853808 |
| 7079GUD24W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler GUD24AH2/E-D(U) | TRUENORTH | 2 tons24,000 Btu/h · Ducted | 2.00 | 100% | 10.0 | 18.0 | CEE 25CEE 26XcelES CC | 2 | 218853786 |
| 7080GUD36W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler GUD36AH2/E-D(U) | TRUENORTH | 3 tons34,000 Btu/h · Ducted | 2.00 | 94% | 10.0 | 18.0 | CEE 25CEE 26XcelES CC | 11 | 218853783 |
| 7081GUD36W2/NHG-D(U)TRUENORTH · G Serieswith ducted air handler GCAC24F/NHA | TRUENORTH | 2 tons24,000 Btu/h · Ducted | 1.85 | 71% | 8.5 | 16.0 | CEE 25CEE 26Xcel | 2 | 218853800 |
| 7082GUD48W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler GUD48AH2/E-D(U) | TRUENORTH | 4 tons48,000 Btu/h · Ducted | 2.00 | 100% | 10.0 | 19.0 | CEE 25CEE 26XcelES CC | 2 | 218853785 |
| 7083GUD60W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler GUD60AH2/E-D(U) | TRUENORTH | 4.5 tons53,000 Btu/h · Ducted | 2.10 | 100% | 10.5 | 18.2 | CEE 25CEE 26CEE AdvXcelDOEES CC | 7 | 218853784 |
| 7084GUD60W2/NHG-D(U)TRUENORTH · G Serieswith ducted air handler GUD60AH2/G-D(U) | TRUENORTH | 4.5 tons53,500 Btu/h · Ducted | 2.24 | 74% | 9.5 | 18.8 | CEE 25CEE 26Xcel | 4 | 218853787 |
| 7085WLUD18W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler WLUD12AH2/E-D(U) | TRUENORTH | 1.5 tons17,000 Btu/h · Ducted | 2.00 | 100% | 9.0 | 18.0 | CEE 25CEE 26XcelES CC | 1 | 218853837 |
| 7086WLUD24W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler WLUD24AH2/E-D(U) | TRUENORTH | 2 tons24,000 Btu/h · Ducted | 2.00 | 100% | 10.0 | 18.0 | CEE 25CEE 26XcelES CC | 2 | 218853815 |
| 7087WLUD36W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler WLUD36AH2/E-D(U) | TRUENORTH | 3 tons34,000 Btu/h · Ducted | 2.00 | 94% | 10.0 | 18.0 | CEE 25CEE 26XcelES CC | 11 | 218853812 |
| 7088WLUD36W2/NHG-D(U)TRUENORTH · G Serieswith ducted air handler WLCAC24F/NHA | TRUENORTH | 2 tons24,000 Btu/h · Ducted | 1.85 | 71% | 8.5 | 16.0 | CEE 25CEE 26Xcel | 2 | 218853829 |
| 7089WLUD48W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler WLUD48AH2/E-D(U) | TRUENORTH | 4 tons48,000 Btu/h · Ducted | 2.00 | 100% | 10.0 | 19.0 | CEE 25CEE 26XcelES CC | 2 | 218853814 |
| 7090WLUD60W2/NHE-D(U)TRUENORTH · E Serieswith ducted air handler WLUD60AH2/E-D(U) | TRUENORTH | 4.5 tons53,000 Btu/h · Ducted | 2.10 | 100% | 10.5 | 18.2 | CEE 25CEE 26CEE AdvXcelDOEES CC | 7 | 218853813 |
| 7091WLUD60W2/NHG-D(U)TRUENORTH · G Serieswith ducted air handler WLUD60AH2/G-D(U) | TRUENORTH | 4.5 tons53,500 Btu/h · Ducted | 2.24 | 74% | 9.5 | 18.8 | CEE 25CEE 26Xcel | 4 | 218853816 |
| 7092WLWH09ATCXB-D6DNA4D/OTRUENORTH · Charmowith ductless indoor unit WLWH09AWCXB-D6DNA1C/I | TRUENORTH | 1 ton9,100 Btu/h · Non-ducted | 1.94 | 76% | 8.8 | 20.5 | CEE 25CEE 26XcelES CC | 1 | 218461819 |
| 7093WLWH18ATDXD-D6DNA4F/OTRUENORTH · Charmowith ductless indoor unit WLWH18AWDXD-D6DNA1A/I | TRUENORTH | 1.5 tons18,000 Btu/h · Non-ducted | 1.85 | 71% | 8.5 | 20.0 | CEE 25CEE 26XcelES CC | 1 | 218461821 |
| 7094WLWH24ATEXF-D6DNA4H/OTRUENORTH · Cosmowith ductless indoor unit WLWH24AWEXF-D6DNA1F/I | TRUENORTH | 2 tons24,000 Btu/h · Non-ducted | 1.81 | 75% | 8.5 | 19.0 | CEE 25CEE 26XcelES CC | 1 | 218461818 |
| 7095WLWHD(18)ND6MOTRUENORTH · M-Series | TRUENORTH | 1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 77% | 10.0 | 21.0 | CEE 25CEE 26XcelES CC | 3 | 218593163 |
| 7096WLWHD(24)ND6MOTRUENORTH · M-Series | TRUENORTH | 2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 90% | 10.0 | 21.0 | CEE 25CEE 26XcelES CC | 3 | 218593164 |
| 7097WLWHD(30)ND6MOTRUENORTH · M-Series | TRUENORTH | 2.5 tons28,400 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.07 | 90% | 10.0 | 21.0 | CEE 25CEE 26XcelES CC | 3 | 218593165 |
| 7098WLWHD(36)ND6MOTRUENORTH · M-Series | TRUENORTH | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 100% | 10.0 | 21.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 218593166 |
| 7099WLWHD(42)ND6MOTRUENORTH · M-Series | TRUENORTH | 3.5 tons42,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 90% | 10.0 | 21.0 | CEE 25CEE 26XcelES CC | 3 | 218593167 |
| 7100WLWHD(60)ND6MOTRUENORTH · Free match | TRUENORTH | 4.5 tons55,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.90 | 66% | 10.0 | 21.0 | CEE 25CEE 26 | 3 | 218593178 |