Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
DOE Cold Climate Heat Pump Challenge: 322 qualifying heat pumps
Rating thresholds from the DOE Residential Cold Climate Heat Pump Technology Challenge.
New to heat pump ratings? The Simple view explains them in plain words →
U.S. Department of EnergyData as of updated · sources
- Share of models
- 2.6%
- Qualifying models
- 322
- Qualifying certifications
- 1,066
- Paths
- 1
Criteria
| Path | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|
| Challenge specification | ≥ 8.5 | ≥ 2.1 | ≥ 100% |
Source: U.S. Department of Energy
Where the thresholds fall
Every model's representative certification on each rating DOE CCHP checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 12 |
| 1.40 to under 1.50 | 79 |
| 1.50 to under 1.60 | 176 |
| 1.60 to under 1.70 | 335 |
| 1.70 to under 1.80 | 1,180 |
| 1.80 to under 1.90 | 2,237 |
| 1.90 to under 2.00 | 1,350 |
| 2.00 to under 2.10 | 2,426 |
| 2.10 to under 2.20 | 1,325 |
| 2.20 to under 2.30 | 778 |
| 2.30 to under 2.40 | 511 |
| 2.40 to under 2.50 | 260 |
| 2.50 to under 2.60 | 215 |
| 2.60 to under 2.70 | 132 |
| 2.70 to under 2.80 | 80 |
| 2.80 to under 2.90 | 51 |
| 2.90 to under 3.00 | 31 |
| 3.00 and above | 40 |
| Baseline: median | 2.00 |
| Baseline: DOE CCHP 2.1 | 2.10 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 51 |
| 30 to under 35% | 28 |
| 35 to under 40% | 337 |
| 40 to under 45% | 467 |
| 45 to under 50% | 520 |
| 50 to under 55% | 565 |
| 55 to under 60% | 526 |
| 60 to under 65% | 684 |
| 65 to under 70% | 763 |
| 70 to under 75% | 2,400 |
| 75 to under 80% | 1,157 |
| 80 to under 85% | 798 |
| 85 to under 90% | 375 |
| 90 to under 95% | 719 |
| 95 to under 100% | 580 |
| 100 to under 105% | 757 |
| 105 to under 110% | 151 |
| 110 to under 115% | 148 |
| 115 to under 120% | 27 |
| 120 to under 125% | 41 |
| 125 to under 130% | 19 |
| 130% and above | 40 |
| Baseline: median | 72% |
| Baseline: DOE CCHP 100% | 100% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 41 |
| 6.5 to under 6.8 | 983 |
| 6.8 to under 7.0 | 64 |
| 7.0 to under 7.3 | 528 |
| 7.3 to under 7.5 | 15 |
| 7.5 to under 7.8 | 1,111 |
| 7.8 to under 8.0 | 383 |
| 8.0 to under 8.3 | 720 |
| 8.3 to under 8.5 | 177 |
| 8.5 to under 8.8 | 1,449 |
| 8.8 to under 9.0 | 196 |
| 9.0 to under 9.3 | 1,501 |
| 9.3 to under 9.5 | 132 |
| 9.5 to under 9.8 | 1,369 |
| 9.8 to under 10.0 | 306 |
| 10.0 to under 10.3 | 1,626 |
| 10.3 to under 10.5 | 228 |
| 10.5 to under 10.8 | 602 |
| 10.8 to under 11.0 | 80 |
| 11.0 to under 11.3 | 294 |
| 11.3 to under 11.5 | 59 |
| 11.5 to under 11.8 | 122 |
| 11.8 to under 12.0 | 21 |
| 12.0 to under 12.3 | 27 |
| 12.3 to under 12.5 | 2 |
| 12.5 to under 12.8 | 92 |
| 12.8 to under 13.0 | 0 |
| 13.0 to under 13.3 | 23 |
| 13.3 to under 13.5 | 9 |
| 13.5 to under 13.8 | 43 |
| 13.8 to under 14.0 | 34 |
| 14.0 and above | 62 |
| Baseline: median | 9.0 |
| Baseline: DOE CCHP 8.5 | 8.5 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons3.6% · 171 of 4,712
- 2 tons2.2% · 38 of 1,747
- 2.5–3 tons2.1% · 58 of 2,722
- 3.5–4.5 tons2% · 53 of 2,687
- 5 tons and up0.4% · 2 of 458
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 3.6% · 171 of 4,712 |
| 2 tons | 2.2% · 38 of 1,747 |
| 2.5–3 tons | 2.1% · 58 of 2,722 |
| 3.5–4.5 tons | 2% · 53 of 2,687 |
| 5 tons and up | 0.4% · 2 of 458 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 1.9% | 114 / 6,060 |
| Non-ducted | 2.4% | 97 / 4,081 |
| Ducted and non-ducted | 5.1% | 111 / 2,185 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 76EHP-O09KBBECO AC · Airy 30SEERwith ductless indoor unit EHP-W09KBB | ECO AC | 1 ton9,100 Btu/h · Non-ducted | 2.11 | 108% | 11.2 | 30.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 216772328 |
| 77EMH-4O36KBBECO AC · Multi-Zone Outdoor | ECO AC | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 100% | 10.0 | 21.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 216772342 |
| 78EDSO-06HECO-AIR · EDS Serieswith ducted air handler EDLS-06U | ECO-AIR | 0.5 tons6,500 Btu/h · Ducted and non-ducted | 2.41 | 98% | 13.8 | 21.4 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 216759958 |
| 79EMXSZ106DAEMI · EMX Serieswith ductless indoor unit EMXWAL06DA | EMI | 0.5 tons6,000 Btu/h · Non-ducted | 2.40 | 110% | 14.8 | 25.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 215444935 |
| 80EMSO21M36ZE230AENVIAIR | ENVIAIR | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 100% | 10.0 | 21.0 | CEE 25CEE 26CEE AdvXcelDOE | 3 | 218472374 |
| 81EMSO30S9AY230AENVIAIRwith ductless indoor unit EMSI30S9AY230A | ENVIAIR | 1 ton9,100 Btu/h · Non-ducted | 2.11 | 108% | 11.2 | 30.0 | CEE 25CEE 26CEE AdvXcelDOE | 1 | 218472370 |
| 82FA-H24-VKCE/OD-454ForestAir · SIDE-DISCHARGEwith ducted air handler FA-H24-VKCE/AH-454 | ForestAir | 2 tons24,000 Btu/h · Ducted | 2.20 | 100% | 9.5 | 18.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 217903145 |
| 83FPHFR48A3DFriedrich · Floating Air Pro Xwith ducted air handler FPHFA48A3D | Friedrich | 4 tons48,000 Btu/h · Ducted and non-ducted | 2.10 | 100% | 10.0 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 17 | 217508872 |
| 84AOUH09KTAP1FUJITSU · AIRSTAGE H-Serieswith ductless indoor unit ASUH09KTAS | Fujitsu | 1 ton9,000 Btu/h · Non-ducted | 2.48 | 142% | 14.0 | 33.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 216018255 |
| 85AOUH09KUAH1FUJITSU · AIRSTAGE H-Serieswith ductless indoor unit AGUH09KUAS | Fujitsu | 1 ton9,000 Btu/h · Non-ducted | 2.16 | 126% | 11.3 | 26.0 | CEE 25CEE 26CEE AdvXcelDOE | 2 | 218807596 |
| 86AOUH09KZAH1FUJITSU · AIRSTAGE H-Serieswith ductless indoor unit ASUH09KZAS | Fujitsu | 1 ton9,000 Btu/h · Non-ducted | 2.26 | 128% | 13.3 | 33.1 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 214888800 |
| 87AOUH12KTAP1FUJITSU · AIRSTAGE H-Serieswith ductless indoor unit ASUH12KTAB | Fujitsu | 1 ton12,000 Btu/h · Non-ducted | 2.62 | 106% | 13.7 | 31.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 217190054 |
| 88AOUH12KUAH1FUJITSU · AIRSTAGE H serieswith ducted air handler ARUH12KUAS | Fujitsu | 1 ton12,000 Btu/h · Ducted and non-ducted | 2.10 | 114% | 10.5 | 19.1 | CEE 25CEE 26CEE AdvXcelDOE | 6 | 218807598 |
| 89AOUH12KZAH1FUJITSU · AIRSTAGE H-Serieswith ductless indoor unit ASUH12KZAS | Fujitsu | 1 ton12,000 Btu/h · Non-ducted | 2.16 | 104% | 12.7 | 30.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 214888802 |
| 90AOUH15KTAP1FUJITSU · AIRSTAGE H-Serieswith ductless indoor unit ASUH15KTAB | Fujitsu | 1 ton14,500 Btu/h · Non-ducted | 2.54 | 106% | 13.0 | 28.7 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 217190055 |
| 91AOUH15KZAH1FUJITSU · AIRSTAGE H-Serieswith ductless indoor unit ASUH15KZAS | Fujitsu | 1 ton14,500 Btu/h · Non-ducted | 2.10 | 117% | 12.7 | 27.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 214888804 |
| 92AOUH18KPAS1FUJITSU · AIRSTAGE H serieswith ductless indoor unit ASUH18KPBS | Fujitsu | 1.5 tons18,000 Btu/h · Non-ducted | 2.24 | 103% | 10.5 | 22.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 218381303 |
| 93AOUH18KUAH1FUJITSU · AIRSTAGE H-serieswith ductless indoor unit ABUH18KUAS | Fujitsu | 1.5 tons18,000 Btu/h · Ducted and non-ducted | 2.30 | 111% | 11.0 | 20.0 | CEE 25CEE 26CEE AdvXcelDOE | 6 | 218814793 |
| 94AOUH18KWAH2FUJITSU · AIRSTAGE H-series | Fujitsu | 1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.18 | 100% | 11.0 | 22.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215447691 |
| 95AOUH24KUAH1FUJITSU · AIRSTAGE H-serieswith ductless indoor unit ABUH24KUAS | Fujitsu | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.10 | 107% | 10.8 | 21.7 | CEE 25CEE 26CEE AdvXcelDOE | 4 | 218814797 |
| 96AOUH24KWAH3FUJITSU · AIRSTAGE H-series | Fujitsu | 2 tons22,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 101% | 11.5 | 23.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215447693 |
| 97AOUH30KUAH1FUJITSU · AIRSTAGE H-serieswith ductless indoor unit AUUH30KUAS | Fujitsu | 2.5 tons30,000 Btu/h · Ducted and non-ducted | 2.16 | 103% | 11.0 | 23.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 217895708 |
| 98NS18H24HA5***GE Applianceswith ducted air handler C(A,C,D,E)24A3J+TDR | GE Appliances | 2 tons22,400 Btu/h · Ducted | 3.13 | 82% | 8.5 | 15.9 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1,278 | 217596950 |
| 99NS18H36HA5***GE Applianceswith indoor coil D(A,C,E)36D4J+TDR and furnace NF97D070V4B | GE Appliances | 3 tons33,000 Btu/h · Ducted | 2.62 | 81% | 8.5 | 17.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1,375 | 217179621 |
| 100NS18H60HA5***GE Applianceswith ducted air handler L(E,G)M48EJ | GE Appliances | 4 tons45,000 Btu/h · Ducted | 2.63 | 80% | 9.5 | 18.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1,643 | 217505636 |