Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 7,174 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

Simple view, for homeowners: top picks by size and what each rating measures →

Xcel EnergyData as of updated · sources

Share of models
52.7%
Qualifying models
7,174
Qualifying certifications
197,833
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F12,514 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+39 above13 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4013
1.40 to under 1.5081
1.50 to under 1.60190
1.60 to under 1.70389
1.70 to under 1.801,291
1.80 to under 1.902,581
1.90 to under 2.001,532
2.00 to under 2.102,675
2.10 to under 2.201,457
2.20 to under 2.30883
2.30 to under 2.40548
2.40 to under 2.50284
2.50 to under 2.60246
2.60 to under 2.70139
2.70 to under 2.8081
2.80 to under 2.9052
2.90 to under 3.0033
3.00 and above39
Baseline: median2.00
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F12,433 rated models · median 72%64% of rated models reach 70% on this rating alone.
+59 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%29
35 to under 40%340
40 to under 45%483
45 to under 50%574
50 to under 55%704
55 to under 60%666
60 to under 65%782
65 to under 70%892
70 to under 75%2,697
75 to under 80%1,230
80 to under 85%910
85 to under 90%410
90 to under 95%798
95 to under 100%623
100 to under 105%825
105 to under 110%148
110 to under 115%151
115 to under 120%23
120 to under 125%38
125% and above59
Baseline: median72%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER213,615 rated models · median 18.1At least 72% of rated models reach 15.2 (the lowest path) on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.028
13.0 to under 13.5910
13.5 to under 14.0372
14.0 to under 14.51,115
14.5 to under 15.0198
15.0 to under 15.51,131
15.5 to under 16.0305
16.0 to under 16.5625
16.5 to under 17.0221
17.0 to under 17.5982
17.5 to under 18.0245
18.0 to under 18.5808
18.5 to under 19.0403
19.0 to under 19.5868
19.5 to under 20.0194
20.0 to under 20.51,156
20.5 to under 21.0179
21.0 to under 21.5851
21.5 to under 22.0172
22.0 to under 22.5571
22.5 to under 23.0220
23.0 to under 23.5729
23.5 to under 24.0120
24.0 to under 24.5340
24.5 to under 25.0157
25.0 to under 25.5302
25.5 to under 26.081
26.0 to under 26.544
26.5 to under 27.019
27.0 to under 27.569
27.5 to under 28.023
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.023
30.0 to under 30.523
30.5 and above54
Baseline: median18.1
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER213,614 rated models · median 11.597% of rated models reach 9 (the lowest path) on this rating alone.
+66 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5112
8.5 to under 9.0248
9.0 to under 9.5805
9.5 to under 10.01,039
10.0 to under 10.5975
10.5 to under 11.01,516
11.0 to under 11.51,966
11.5 to under 12.01,967
12.0 to under 12.52,024
12.5 to under 13.0985
13.0 to under 13.5988
13.5 to under 14.0242
14.0 to under 14.5299
14.5 to under 15.0123
15.0 to under 15.5189
15.5 to under 16.06
16.0 to under 16.537
16.5 to under 17.023
17.0 and above66
Baseline: median11.5
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons60.7% · 3,292 of 5,427
2 tons59.4% · 1,152 of 1,941
2.5 to 3 tons50.4% · 1,483 of 2,942
3.5 to 4.5 tons42.2% · 1,195 of 2,834
5 tons and up10.9% · 52 of 475

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted32.2%2,070 / 6,438
Non-ducted61.3%2,978 / 4,861
Ducted and non-ducted91.6%2,126 / 2,320

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree584 of 72980.1%
Midea387 of 55569.7%
Carrier246 of 84629.1%
TCL138 of 19271.9%
BlueRidge132 of 19468%
Daikin125 of 41030.5%
AUX124 of 18965.6%
Lennox121 of 34135.5%
Ephoca120 of 38231.4%
Innova120 of 38231.4%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 53 of 287
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
1301A-ZHP15SA-1CENTURY · A-ZHP Serieswith ducted air handler B-ZHP15SA-1Century1.5 tons15,000 Btu/h · Ducted2.0090%11.027.0CEE 25CEE 26XcelES CC1218404563
1302HP19V24S1ACenturywith ducted air handler AH19X24S1ACentury2 tons24,000 Btu/h · Ducted1.8075%9.018.0CEE 25CEE 26Xcel1217604107
1303HP19V24S1A-CYCenturywith ducted air handler AH19X24S1A-CYCentury2 tons24,000 Btu/h · Ducted1.8075%9.018.0CEE 25CEE 26Xcel1217604111
1304HP19V36S1ACenturywith ducted air handler AH19X36S1ACentury2 tons24,000 Btu/h · Ducted1.9083%9.019.0CEE 25CEE 26Xcel1217604108
1305HP19V36S1A-CYCenturywith ducted air handler AH19X36S1A-CYCentury2 tons24,000 Btu/h · Ducted1.9083%9.019.0CEE 25CEE 26Xcel1217604112
1306HSA1936V1-**ACentury · HSA19 Serieswith indoor coil 7ED48CX-**+TDR and furnace GDD92C090C4MPCentury3 tons34,800 Btu/h · Ducted2.2048%8.516.0CEE 25CEE 26Xcel149217504360
1307CATA-24NA23BCH18-OChillAirewith indoor coil CATA-24NA23BCH-I and furnace CATA-24NA23BCH18-OChillAire2 tons24,000 Btu/h · Ducted1.8075%9.018.0CEE 25CEE 26Xcel1218852773
1308CATA-36NA23BCH18-OChillAirewith indoor coil CATA-36NA23BCH-I and furnace CATA-36NA23BCH18-OChillAire3 tons34,000 Btu/h · Ducted1.9076%9.019.0CEE 25CEE 26Xcel1218852774
1309CPEM18HPR36-2301A*CIAC EliteCIAC Elite3 tons34,200 Btu/h · Ducted1.8671%8.218.5Xcel1218814649
1310CPEM18HPR60-2301A*CIAC EliteCIAC Elite4.5 tons55,000 Btu/h · Ducted1.8281%8.818.5CEE 25CEE 26Xcel1218814650
1311GMRSHC18AS2CLASSIC · M-SeriesCLASSIC1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0077%10.021.0CEE 25CEE 26XcelES CC3217284803
1312GMRSHC24AS3CLASSIC · M-SeriesCLASSIC2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0090%10.021.0CEE 25CEE 26XcelES CC3217284804
1313GMRSHC36AS4CLASSIC · M-SeriesCLASSIC3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.10100%10.021.0CEE 25CEE 26CEE AdvXcelDOEES CC3217284815
1314GMRSHC42AS5CLASSIC · M-SeriesCLASSIC3.5 tons42,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1090%10.021.0CEE 25CEE 26XcelES CC3217284816
1315GRH32IC09ASCLASSICwith ductless indoor unit GWH32IC09SCLASSIC1 ton9,100 Btu/h · Non-ducted1.9079%9.222.0CEE 25CEE 26Xcel1216025765
1316GRH32IC09ASACLASSIC · Arctic Inverter Serieswith ductless indoor unit GWH32IC09SACLASSIC1 ton9,100 Btu/h · Non-ducted1.9079%9.222.0CEE 25CEE 26Xcel1216723116
1317GRH32IC12ASCLASSIC · Zenowith ductless indoor unit GWH32IC12SCLASSIC1 ton12,000 Btu/h · Non-ducted1.9078%8.521.5CEE 25CEE 26XcelES CC1216025772
1318GRH32IC12ASACLASSIC · Zenowith ductless indoor unit GWH32IC12SACLASSIC1 ton12,000 Btu/h · Non-ducted1.9071%8.521.5CEE 25CEE 26XcelES CC1216025771
1319GRH32IC18ASCLASSIC · Zenowith ductless indoor unit GWH32IC18SCLASSIC1.5 tons18,000 Btu/h · Non-ducted1.9070%8.521.5CEE 25CEE 26XcelES CC1216025773
1320GRH32IC36ASCLASSIC · All MATCHwith ductless indoor unit GC4VHC36SLDCLASSIC3 tons33,600 Btu/h · Non-ducted1.9069%8.521.0CEE 25CEE 26XcelES CC2217994507
1321GRHFR32C09ASCLASSICwith ductless indoor unit GWHFR32C09SCLASSIC1 ton9,100 Btu/h · Non-ducted1.8576%8.618.8CEE 25CEE 26Xcel1217550354
1322GRHFR32C12AS2CLASSICwith ductless indoor unit GC4VHC12SLDCLASSIC1 ton12,000 Btu/h · Non-ducted1.9083%8.317.5Xcel2217994511
1323GRHFR32C24ASCLASSICwith ductless indoor unit GWHFR32C24SCLASSIC2 tons24,000 Btu/h · Non-ducted1.7570%8.519.0CEE 25CEE 26Xcel3217550362
1324GWHFR32C09SCLASSICwith ductless indoor unit GRHFR32C09ASCLASSIC1 ton9,100 Btu/h · Non-ducted1.8576%8.618.8CEE 25CEE 26Xcel1217463611
1325GWHFR32C24SCLASSICwith ductless indoor unit GRHFR32C24ASCLASSIC2 tons24,000 Btu/h · Non-ducted1.7570%8.519.0CEE 25CEE 26Xcel1217463619

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter