Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 6,515 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

New to heat pump ratings? The Simple view explains them in plain words →

Xcel EnergyData as of updated · sources

Share of models
52.8%
Qualifying models
6,515
Qualifying certifications
189,411
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F11,219 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+40 above12 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4012
1.40 to under 1.5079
1.50 to under 1.60176
1.60 to under 1.70335
1.70 to under 1.801,180
1.80 to under 1.902,238
1.90 to under 2.001,350
2.00 to under 2.102,426
2.10 to under 2.201,325
2.20 to under 2.30778
2.30 to under 2.40511
2.40 to under 2.50260
2.50 to under 2.60215
2.60 to under 2.70132
2.70 to under 2.8080
2.80 to under 2.9051
2.90 to under 3.0031
3.00 and above40
Baseline: median2.00
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F11,154 rated models · median 72%65% of rated models reach 70% on this rating alone.
+40 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%28
35 to under 40%337
40 to under 45%467
45 to under 50%519
50 to under 55%566
55 to under 60%526
60 to under 65%684
65 to under 70%763
70 to under 75%2,401
75 to under 80%1,156
80 to under 85%798
85 to under 90%375
90 to under 95%720
95 to under 100%580
100 to under 105%757
105 to under 110%151
110 to under 115%148
115 to under 120%27
120 to under 125%41
125 to under 130%19
130% and above40
Baseline: median72%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER212,328 rated models · median 18.0At least 71% of rated models reach 15.2 (the lowest path) on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.014
13.0 to under 13.5900
13.5 to under 14.0338
14.0 to under 14.51,002
14.5 to under 15.0192
15.0 to under 15.51,101
15.5 to under 16.0284
16.0 to under 16.5624
16.5 to under 17.0188
17.0 to under 17.5849
17.5 to under 18.0214
18.0 to under 18.5680
18.5 to under 19.0393
19.0 to under 19.5745
19.5 to under 20.0182
20.0 to under 20.5917
20.5 to under 21.0162
21.0 to under 21.5783
21.5 to under 22.0162
22.0 to under 22.5508
22.5 to under 23.0197
23.0 to under 23.5661
23.5 to under 24.0111
24.0 to under 24.5294
24.5 to under 25.0151
25.0 to under 25.5286
25.5 to under 26.075
26.0 to under 26.539
26.5 to under 27.018
27.0 to under 27.560
27.5 to under 28.022
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.022
30.0 to under 30.523
30.5 and above54
Baseline: median18.0
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER212,324 rated models · median 11.597% of rated models reach 9 (the lowest path) on this rating alone.
+31 above2 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.02
8.0 to under 8.595
8.5 to under 9.0214
9.0 to under 9.5702
9.5 to under 10.0831
10.0 to under 10.5881
10.5 to under 11.01,359
11.0 to under 11.51,678
11.5 to under 12.01,904
12.0 to under 12.51,869
12.5 to under 13.0951
13.0 to under 13.5914
13.5 to under 14.0232
14.0 to under 14.5274
14.5 to under 15.0114
15.0 to under 15.5179
15.5 to under 16.05
16.0 to under 16.531
16.5 to under 17.023
17.0 to under 17.535
17.5 and above31
Baseline: median11.5
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons61.6% · 2,905 of 4,715
2 tons60.8% · 1,062 of 1,748
2.5–3 tons50.3% · 1,369 of 2,724
3.5–4.5 tons42.1% · 1,130 of 2,687
5 tons and up10.7% · 49 of 458

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted31.9%1,933 / 6,056
Non-ducted63%2,573 / 4,087
Ducted and non-ducted91.8%2,009 / 2,189

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree574 of 71780.1%
Midea381 of 54669.8%
Carrier223 of 81627.3%
BlueRidge131 of 19268.2%
TCL128 of 17772.3%
Lennox121 of 33735.9%
Ephoca120 of 38231.4%
Daikin117 of 39429.7%
Rheem115 of 34133.7%
Hisense110 of 16168.3%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 89 of 261
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
2201FPHMR18A3DFriedrich · Floating Air Pro X Multi-ZoneFriedrich1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.99100%10.022.0CEE 25CEE 26XcelES CC3215792836
2202FPHMR27A3DFriedrich · Floating Air Pro X Multi-ZoneFriedrich2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.80100%10.023.0CEE 25CEE 26XcelES CC3215792839
2203FPHMR36A3DFriedrich · Floating Air Pro X Multi-ZoneFriedrich3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.90100%10.022.0CEE 25CEE 26XcelES CC3215792846
2204FPHMR42A3DFriedrich · Floating Air Pro X Multi-ZoneFriedrich3.5 tons42,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9075%9.522.0CEE 25CEE 26XcelES CC3215792843
2205FPHSR09A1BFRIEDRICHwith ductless indoor unit FAHSW09A1AFriedrich1 ton9,000 Btu/h · Non-ducted1.9097%10.023.0CEE 25CEE 26XcelES CC2214826547
2206FPHSR09A1CFriedrich · Floating Air Prowith ductless indoor unit FAHSW09A1CFriedrich1 ton9,000 Btu/h · Non-ducted1.9097%10.023.0CEE 25CEE 26XcelES CC2215792219
2207FPHSR09A3BFRIEDRICH · Floating Air Prowith ductless indoor unit FAHFW09A3AFriedrich1 ton9,000 Btu/h · Non-ducted2.09100%11.025.0CEE 25CEE 26XcelES CC2214232408
2208FPHSR09A3DFriedrich · Floating Air Prowith ductless indoor unit FAHFW09A3DFriedrich1 ton9,000 Btu/h · Non-ducted2.09100%11.025.0CEE 25CEE 26XcelES CC2215792221
2209FPHSR12A1BFRIEDRICHwith ductless indoor unit FAHSW12A1AFriedrich1 ton12,000 Btu/h · Non-ducted1.9077%9.522.0CEE 25CEE 26XcelES CC2214826548
2210FPHSR12A1CFriedrich · Floating Air Prowith ductless indoor unit FAHSW12A1CFriedrich1 ton12,000 Btu/h · Non-ducted1.9077%9.522.0CEE 25CEE 26XcelES CC2215792220
2211FPHSR12A3BFRIEDRICH · Floating Air Prowith ductless indoor unit FAHFW12A3AFriedrich1 ton12,000 Btu/h · Non-ducted2.0092%10.023.0CEE 25CEE 26XcelES CC2214237688
2212FPHSR12A3DFriedrich · Floating Air Prowith ductless indoor unit FAHFW12A3DFriedrich1 ton12,000 Btu/h · Non-ducted2.0092%10.023.0CEE 25CEE 26XcelES CC2215792222
2213FPHSR18A3BFRIEDRICH · Floating Air Prowith ductless indoor unit FAHFW18A3AFriedrich1.5 tons18,000 Btu/h · Non-ducted1.90100%10.021.0CEE 25CEE 26XcelES CC2214142519
2214FPHSR18A3DFriedrich · Floating Air Prowith ductless indoor unit FAHFW18A3DFriedrich1.5 tons18,000 Btu/h · Non-ducted1.90100%10.021.0CEE 25CEE 26XcelES CC2215792223
2215FPHSR24A3BFRIEDRICH · Floating Air Prowith ductless indoor unit FAHFW24A3AFriedrich2 tons24,000 Btu/h · Non-ducted2.0083%9.522.5CEE 25CEE 26XcelES CC2214091820
2216FPHSR24A3DFriedrich · Floating Air Prowith ductless indoor unit FAHFW24A3DFriedrich2 tons24,000 Btu/h · Non-ducted2.0083%9.522.5CEE 25CEE 26XcelES CC2215792224
2217FRP17AY24AJVCFRIEDRICH · F-Series Pluswith indoor coil RCFY2417STANM and furnace FR972V0403A14UDSFriedrich2 tons22,400 Btu/h · Ducted2.2072%8.116.0CEE 25CEE 26XcelES CC92218719256
2218FRP17AY36AJVCFRIEDRICH · F-Series Pluswith indoor coil RCFY3617STANM and furnace FR801V0503A14DZNFriedrich3 tons34,200 Btu/h · Ducted2.0091%9.516.0CEE 25CEE 26XcelES CC246218327885
2219FRP17AY48AJVCFRIEDRICH · F-Series Pluswith indoor coil RCFY4821STANM and furnace FR972V0705A21UPSFriedrich3.5 tons44,500 Btu/h · Ducted2.1075%9.516.0CEE 25CEE 26XcelES CC192218719321
2220FRP17AY60AJVCFRIEDRICH · F-Series Pluswith indoor coil RCFY6024STANM and furnace FR802V1005A21UHSFriedrich4.5 tons56,500 Btu/h · Ducted2.0080%9.516.0CEE 25CEE 26XcelES CC79218328121
2221FRP19AY24AJVCFRIEDRICH · K SERIESwith indoor coil TCFY2421HEAAM and furnace FR972V0603A17UPSFriedrich2 tons22,800 Btu/h · Ducted2.1077%8.521.0CEE 25CEE 26XcelES CC60218728652
2222FRP19AY36AJVCFRIEDRICH · K SERIESwith indoor coil RCFY3621MEAAM and furnace FR972V0603A17UPSFriedrich3 tons34,200 Btu/h · Ducted2.2077%8.520.0CEE 25CEE 26XcelES CC37218728667
2223FRP19AY48AJVCFRIEDRICH · K SERIESwith indoor coil RCFY4821SEAAM and furnace FR972V0705A21UPSFriedrich4 tons45,500 Btu/h · Ducted2.2076%8.519.0CEE 25CEE 26Xcel28218728685
2224FRP19AY60AJVCFRIEDRICH · K SERIESwith indoor coil RCFY6021SEAAM and furnace FR972V0855A21UPSFriedrich4.5 tons53,500 Btu/h · Ducted2.1084%8.117.0CEE 25CEE 26Xcel27218728700
2225FSHSR18B3BFRIEDRICHwith ductless indoor unit FAHFW18A3AFriedrich1.5 tons18,000 Btu/h · Non-ducted2.4076%9.821.0CEE 25CEE 26Xcel2214604197

Explore qualifying models by COP at 5°F