MITS AIR has 6 heat pump outdoor models certified with this refrigerant group, in 20 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes MITS AIR makes. MITS AIR has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 6
- AHRI certifications
- 20
- Efficiency index
- 58%
- Typical model vs same-size, same-type peers (6 models)
- Meet CEE 2025
- 100%
- 6 models
How MITS AIR compares with comparable models
- MITS AIR
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index6 models scored | 58% | Not ranked | — |
| COP at 5°F6 models scored | 42% | Not ranked | 1.90 |
| Capacity retention at 5°F6 models scored | 80% | Not ranked | 93% |
| HSPF26 models scored | 76% | Not ranked | 9.8 |
| SEER26 models scored | 55% | Not ranked | 16.7 |
| EER26 models scored | 47% | Not ranked | 11.7 |
| Heating capacity at 5°F6 models scored | 84% | Not ranked | 35,800 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100% | 6 |
| CEE 2026 Tier 1 (Split ASHP) | 100% | 6 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 100% | 6 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 100% | 6 |
Sizes and duct types offered
- MITS AIR (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 1 | 63% | 72% | 62% | 52% |
| Ducted, 2 tons | 1 | 61% | 34% | 85% | 63% |
| Ducted, 2.5–3 tons | 2 | 65% | 37% | 89% | 57% |
| Ducted, 3.5–4.5 tons | 2 | 48% | 35% | 65% | 50% |
Every MITS AIR model in the market
- MITS AIR models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top MITS AIR models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1MAMOX630-36HFN10-M3XMITS AIRwith ducted air handler MAMVBC-36HWFN10-MC3E-D | 3 tons36,000 Btu/h · Ducted | 105% | 1.90 | 10.3 | 39,000 | 17.4 | CEE 25CEE 26XcelES CC | 4 | 216621513 | Ducted, 2.5–3 tons | 73.1 |
| 2MAMOX430-18HFN10-M3XMITS AIRwith ducted air handler MAMVBM-24A18T3N10 | 1.5 tons18,000 Btu/h · Ducted | 95% | 2.06 | 9.5 | 18,000 | 16.1 | CEE 25CEE 26XcelES CC | 3 | 216621516 | Ducted, up to 1.5 tons | 72.8 |
| 3MAMOD30-30HFN10-M3XMITS AIRwith ducted air handler MAMVBM-36B24T4N10 | 2.5 tons29,000 Btu/h · Ducted | 107% | 1.85 | 9.6 | 32,000 | 16.0 | CEE 25CEE 26XcelES CC | 4 | 216621521 | Ducted, 2.5–3 tons | 68.8 |
| 4MAMOX630-48HFN10-M3XMITS AIRwith ducted air handler MAMVBC-48HWFN10-MD3E-D | 4 tons48,000 Btu/h · Ducted | 92% | 1.90 | 9.5 | 46,000 | 16.5 | CEE 25CEE 26XcelES CC | 3 | 216621514 | Ducted, 3.5–4.5 tons | 68.8 |
| 5MAMOX430-24HFN10-M3XMITS AIRwith ducted air handler MAMVBC-24HWFN10-MB3E-D | 2 tons23,000 Btu/h · Ducted | 90% | 1.87 | 10.0 | 21,600 | 18.3 | CEE 25CEE 26XcelES CC | 3 | 216621511 | Ducted, 2 tons | 66.3 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1MAMOX430-18HFN10-M3XMITS AIRwith ducted air handler MAMVBC-18HWFN10-MB3E-D | 1.5 tons18,000 Btu/h · Ducted | 95% | 2.00 | 9.7 | 19.0 | 12.5 | CEE 25CEE 26XcelES CC | 3 | 216621510 | Ducted, up to 1.5 tons | 71.7 | 70.4 | 73.1 | 72.8 |
| 2MAMOX630-36HFN10-M3XMITS AIRwith ducted air handler MAMVBC-36HWFN10-MC3E-D | 3 tons36,000 Btu/h · Ducted | 105% | 1.90 | 10.3 | 17.4 | 11.7 | CEE 25CEE 26XcelES CC | 4 | 216621513 | Ducted, 2.5–3 tons | 67.3 | 73.1 | 61.5 | 73.1 |
| 3MAMOD30-30HFN10-M3XMITS AIRwith ducted air handler MAMVBC-30HWFN10-MC3E-D | 2.5 tons30,000 Btu/h · Ducted | 96% | 1.96 | 10.0 | 16.8 | 11.7 | CEE 25CEE 26XcelES CC | 4 | 216621512 | Ducted, 2.5–3 tons | 63.0 | 68.7 | 57.4 | 68.8 |
| 4MAMOX430-24HFN10-M3XMITS AIRwith ducted air handler MAMVBC-24HWFN10-MB3E-D | 2 tons23,000 Btu/h · Ducted | 90% | 1.87 | 10.0 | 18.3 | 11.7 | CEE 25CEE 26XcelES CC | 3 | 216621511 | Ducted, 2 tons | 61.0 | 66.3 | 55.6 | 66.3 |
| 5MAMOX630-48HFN10-M3XMITS AIRwith ducted air handler MAMVBC-48HWFN10-MD3E-D | 4 tons48,000 Btu/h · Ducted | 92% | 1.90 | 9.5 | 16.5 | 10.5 | CEE 25CEE 26XcelES CC | 3 | 216621514 | Ducted, 3.5–4.5 tons | 57.1 | 68.8 | 45.3 | 68.8 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | MAMOX430-18HFN10-M3X | 2.06 | Ducted, up to 1.5 tons | 72% | 216621516 |
| Capacity retention at 5°F | MAMOD30-30HFN10-M3X | 107% | Ducted, 2.5–3 tons | 97% | 216621521 |
| HSPF2 | MAMOX630-36HFN10-M3X | 10.3 | Ducted, 2.5–3 tons | 91% | 216621513 |
| SEER2 | MAMOX430-18HFN10-M3X | 19.0 | Ducted, up to 1.5 tons | 66% | 216621510 |
| EER2 | MAMOX430-18HFN10-M3X | 12.5 | Ducted, up to 1.5 tons | 76% | 216621510 |
| Heating capacity at 5°F | MAMOX630-36HFN10-M3X | 39,000 Btu/h | Ducted, 2.5–3 tons | 97% | 216621513 |
MITS AIR size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 72.8(50 is the typical model of its size class)MAMOX430-18HFN10-M3Xwith ducted air handler MAMVBM-24A18T3N101 of 1 models qualify · AHRI 216621516 | 71.7(50 is the typical model of its size class)MAMOX430-18HFN10-M3Xwith ducted air handler MAMVBC-18HWFN10-MB3E-D1 of 1 models have all five ratings · AHRI 216621510 |
| Ducted, 2 tons | 66.3(50 is the typical model of its size class)MAMOX430-24HFN10-M3Xwith ducted air handler MAMVBC-24HWFN10-MB3E-D1 of 1 models qualify · AHRI 216621511 | 61.0(50 is the typical model of its size class)MAMOX430-24HFN10-M3Xwith ducted air handler MAMVBC-24HWFN10-MB3E-D1 of 1 models have all five ratings · AHRI 216621511 |
| Ducted, 2.5–3 tons | 73.1(50 is the typical model of its size class)MAMOX630-36HFN10-M3Xwith ducted air handler MAMVBC-36HWFN10-MC3E-D2 of 2 models qualify · AHRI 216621513 | 67.3(50 is the typical model of its size class)MAMOX630-36HFN10-M3Xwith ducted air handler MAMVBC-36HWFN10-MC3E-D2 of 2 models have all five ratings · AHRI 216621513 |
| Ducted, 3.5–4.5 tons | 68.8(50 is the typical model of its size class)MAMOX630-48HFN10-M3Xwith ducted air handler MAMVBC-48HWFN10-MD3E-D2 of 2 models qualify · AHRI 216621514 | 57.1(50 is the typical model of its size class)MAMOX630-48HFN10-M3Xwith ducted air handler MAMVBC-48HWFN10-MD3E-D2 of 2 models have all five ratings · AHRI 216621514 |
Newest MITS AIR certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| MAMOX630-48HFN10-M3XMITS AIRwith ducted air handler MAMVBM-60D28T6N10 | 4 tons45,000 Btu/h · Ducted | 1.80 | 85% | 8.4 | 14.5 | CEE 25CEE 26XcelES CC | 3 | 217284771 |
| MAMOX630-36HFN10-M3XMITS AIRwith ducted air handler MAMVBM-36A24T4N10 | 3 tons33,000 Btu/h · Ducted | 1.56 | 96% | 8.7 | 14.6 | CEE 25CEE 26XcelES CC | 4 | 217284770 |
| MAMOE30-60HFN10-M3XMITS AIRwith ducted air handler MAMVBM-60D28T6N10 | 4 tons47,000 Btu/h · Ducted | 1.83 | 74% | 8.1 | 15.2 | CEE 25CEE 26XcelES CC | 3 | 216621526 |
| MAMOD30-30HFN10-M3XMITS AIRwith ducted air handler MAMVBM-36C24T4N10 | 2.5 tons29,000 Btu/h · Ducted | 1.85 | 107% | 9.6 | 16.0 | CEE 25CEE 26XcelES CC | 4 | 216621522 |
| MAMOX430-24HFN10-M3XMITS AIRwith ducted air handler MAMVBM-24B18T3N10 | 2 tons24,000 Btu/h · Ducted | 1.80 | 84% | 9.5 | 16.0 | CEE 25CEE 26XcelES CC | 3 | 216621519 |
Compare MITS AIR