Skip to content

Friedrich vs MRCOOL heat pumps

Measured against models of the same size and duct type, MRCOOL scores higher on 6 of the 6 ratings. Friedrich has 188 outdoor models, MRCOOL has 92 outdoor models.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Friedrich and MRCOOL on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, MRCOOL scores higher on 6 of the 6 ratings.
  • Friedrich
  • MRCOOL
  • Other ranked manufacturers
FriedrichMRCOOL

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingFriedrichMRCOOL
Efficiency index39%median — · 28th ranked53%median — · 17th ranked
COP at 5°F46%median 1.99 · 22nd ranked50%median 1.99 · 19th ranked
Capacity retention at 5°F36%median 52% · 26th ranked50%median 73% · 17th ranked
HSPF231%median 7.5 · 28th ranked56%median 9.2 · 11th ranked
SEER234%median 15.2 · 28th ranked54%median 18.8 · 15th ranked
EER237%median 10.6 · 27th ranked49%median 11.7 · 17th ranked
Heating capacity at 5°F35%median 17,000 Btu/h · 28th ranked52%median 17,100 Btu/h · 16th ranked
Outdoor models18892
AHRI certifications6,657504

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardFriedrichMRCOOL
CEE 2025 Tier 1 (Split ASHP)26.6%50 models67.4%62 models
CEE 2026 Tier 1 (Split ASHP)23.9%45 models66.3%61 models
CEE Advanced Tier (Split ASHP)0.5%1 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)21.3%40 models57.6%53 models
DOE Cold Climate Heat Pump Challenge0.5%1 models0%0 models
ENERGY STAR Cold Climate22.3%42 models56.5%52 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 8 groups where both have models
  • Friedrich
  • MRCOOL
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeFriedrichMRCOOL
Ducted, up to 1.5 tons21 · index 30%10 · index 67%
Ducted, 2 tons21 · index 31%12 · index 57%
Ducted, 2.5–3 tons46 · index 37%15 · index 52%
Ducted, 3.5–4.5 tons58 · index 41%19 · index 54%
Ducted, 5 tons and up21 · index 31%None
Non-ducted, up to 1.5 tons20 · index 55%35 · index 51%
Non-ducted, 2 tons5 · index 50%10 · index 47%
Non-ducted, 2.5–3 tons4 · index 47%6 · index 34%
Non-ducted, 3.5–4.5 tons2 · index 47%3 · index 61%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeFriedrichCold-climate score, best modelMRCOOLCold-climate score, best model
Ducted, up to 1.5 tons73.0(50 is the typical model of its size class)FPHFR24A3Dwith ducted air handler FPHFA18A3D5 of 21 models qualify · AHRI 21750565780.0(50 is the typical model of its size class) (higher)O-HH-09-HP-C-230C-Owith ducted air handler DUCT-09HP-230B-OAlso listed as O-ES-09-HP-C-230C-O18 of 10 models qualify · AHRI 216032559
Ducted, 2 tons70.3(50 is the typical model of its size class)RD18AY24AJVCwith indoor coil RCFY2417STANM and furnace FR801V0504A17UHU4 of 21 models qualify · AHRI 21717602186.4(50 is the typical model of its size class) (higher)O-ES-24-HP-C-230C-O1with ducted air handler O-18-HP-WMAH-235C-O10 of 12 models qualify · AHRI 217447812
Ducted, 2.5–3 tons78.1(50 is the typical model of its size class) (higher)RD18AY36AJVCwith indoor coil RCFY3621MTANM and furnace FR801V0504A17UHN6 of 46 models qualify · AHRI 21689124677.0(50 is the typical model of its size class)UHP18030-Owith ducted air handler UAH18030 - O9 of 15 models qualify · AHRI 217730329
Ducted, 3.5–4.5 tons83.9(50 is the typical model of its size class) (higher)FPHFR48A3Dwith ducted air handler FPHFA48A3D8 of 57 models qualify · AHRI 21750887277.9(50 is the typical model of its size class)MULTI6-48HP230C-O13 of 19 models qualify · AHRI 217291702
Ducted, 5 tons and up77.3(50 is the typical model of its size class)FRP17AY60AJVCwith indoor coil RCFY6024STANM and furnace FR802V1255A24UHN1 of 22 models qualify · AHRI 218328124No models in this size class
Non-ducted, up to 1.5 tons82.4(50 is the typical model of its size class) (higher)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D16 of 20 models qualify · AHRI 21423240880.4(50 is the typical model of its size class)DIYHH-12-HP-C-230D25-Owith ductless indoor unit DIYCASSETTE12HP-230D25-O22 of 35 models qualify · AHRI 216032550
Non-ducted, 2 tons76.3(50 is the typical model of its size class)FPHFR24A3Dwith ductless indoor unit FPHFC24A3D5 of 5 models qualify · AHRI 21662615589.4(50 is the typical model of its size class) (higher)O-HH-24-HP-C-230C-Owith ductless indoor unit CASSETTE24HP-230C-OAlso listed as O-ES-24-HP-C-230C-O16 of 10 models qualify · AHRI 216032567
Non-ducted, 2.5–3 tons58.2(50 is the typical model of its size class) (higher)FPHFR36A3Dwith ductless indoor unit FPHSC36A3D3 of 4 models qualify · AHRI 21669960841.4(50 is the typical model of its size class)MULTI4-27HP230C-O3 of 6 models qualify · AHRI 217291695
Non-ducted, 3.5–4.5 tons49.7(50 is the typical model of its size class)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models qualify · AHRI 21669960956.1(50 is the typical model of its size class) (higher)MULTI6-48HP230C-O3 of 3 models qualify · AHRI 217291703

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeFriedrichAll-around score, best modelMRCOOLAll-around score, best model
Ducted, up to 1.5 tons67.4(50 is the typical model of its size class)FPHFR24A3Dwith ducted air handler FPHFA18A3D20 of 20 models have all five ratings · AHRI 21750565786.7(50 is the typical model of its size class) (higher)O-HH-09-HP-C-230C-Owith ducted air handler DUCT-09HP-230B-OAlso listed as O-ES-09-HP-C-230C-O19 of 10 models have all five ratings · AHRI 216032559
Ducted, 2 tons75.1(50 is the typical model of its size class)FRP19AY24AJVCwith indoor coil RCFY2421HEAAM and furnace FR951V0603A17M421 of 21 models have all five ratings · AHRI 21655163378.7(50 is the typical model of its size class) (higher)O-ES-24-HP-C-230C-O1with ducted air handler O-18-HP-WMAH-235C-O11 of 12 models have all five ratings · AHRI 217447812
Ducted, 2.5–3 tons84.1(50 is the typical model of its size class) (higher)RD18AY36AJVCwith ducted air handler RH2VY3621MTACN30 of 46 models have all five ratings · AHRI 21661317073.4(50 is the typical model of its size class)UHP18030-Owith ducted air handler UAH18030 - O13 of 15 models have all five ratings · AHRI 217730329
Ducted, 3.5–4.5 tons84.1(50 is the typical model of its size class)FRP19AY48AJVCwith indoor coil RCFY4821SEAAM and furnace FR802V0754A17UH32 of 54 models have all five ratings · AHRI 21655182785.1(50 is the typical model of its size class) (higher)MULTI6-48HP230C-O16 of 19 models have all five ratings · AHRI 217291702
Ducted, 5 tons and up70.3(50 is the typical model of its size class)FRP17AY60AJVCwith ducted air handler RH2TY6024STANN14 of 26 models have all five ratings · AHRI 218328406No models in this size class
Non-ducted, up to 1.5 tons83.9(50 is the typical model of its size class) (higher)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D20 of 20 models have all five ratings · AHRI 21423240880.6(50 is the typical model of its size class)O-HH-09-HP-C-230C-Owith ductless indoor unit O-09-HP-WMAH-230C-OAlso listed as O-ES-09-HP-C-230C-O135 of 35 models have all five ratings · AHRI 216032557
Non-ducted, 2 tons61.6(50 is the typical model of its size class)FPHSR24A3Bwith ductless indoor unit FAHFW24A3AAlso listed as FPHSR24A3D5 of 5 models have all five ratings · AHRI 21409182076.8(50 is the typical model of its size class) (higher)O-ES-24-HP-C-230C-O1with ductless indoor unit O-18-HP-WMAH-233C-O10 of 10 models have all five ratings · AHRI 217447810
Non-ducted, 2.5–3 tons64.2(50 is the typical model of its size class)FPHMR27A3D4 of 4 models have all five ratings · AHRI 21579283966.3(50 is the typical model of its size class) (higher)MULTI4-27HP230C-O6 of 6 models have all five ratings · AHRI 217291695
Non-ducted, 3.5–4.5 tons49.6(50 is the typical model of its size class)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models have all five ratings · AHRI 21669960968.6(50 is the typical model of its size class) (higher)MULTI6-48HP230C-O3 of 3 models have all five ratings · AHRI 217291703

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingFriedrichMRCOOL
COP at 5°Fbeats 98% · 2.61WFPU17Y243DDucted, up to 1.5 tonsbeats 98% · 2.44DIY-18-HP-C-230D25-OAlso listed as DIYP-18-HP-C-230DE11-ONon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 100% · 133%FPHFR09A3DDucted, up to 1.5 tonsbeats 99% · 126%MDPH18024DDucted, 2 tons
HSPF2beats 86% · 10.0FRP19AY60AJVCDucted, 3.5–4.5 tonsbeats 98% · 13.5O-HH-24-HP-C-230C-ONon-ducted, 2 tons
SEER2beats 98% · 21.0FRP19AY36AJVCDucted, 2.5–3 tonsbeats 97% · 25.0MULTI4-27HP230C-ONon-ducted, 2.5–3 tons
EER2beats 96% · 13.0RD18AY36AJVCDucted, 2.5–3 tonsbeats 95% · 15.4O-HH-09-HP-C-230C-OAlso listed as O-ES-09-HP-C-230C-O1Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 96% · 18,600 Btu/hRD18AY24AJVCDucted, up to 1.5 tonsbeats 99% · 30,300 Btu/hMDPH18024DDucted, 2 tons

More comparisons