Both views use the same certified data. This device remembers your choice.
Friedrich vs MRCOOL heat pumps
Measured against models of the same size and duct type, MRCOOL scores higher on 6 of the 6 ratings. Friedrich has 192 outdoor models, MRCOOL has 92 outdoor models.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Friedrich
- MRCOOL
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Friedrich | MRCOOL |
|---|---|---|
| Efficiency index | 40%median — · 28th ranked | 54%median — · 15th ranked |
| COP at 5°F | 46%median 1.99 · 22nd ranked | 50%median 1.99 · 19th ranked |
| Capacity retention at 5°F | 36%median 51% · 27th ranked | 51%median 73% · 16th ranked |
| HSPF2 | 32%median 7.5 · 28th ranked | 57%median 9.2 · 11th ranked |
| SEER2 | 35%median 15.2 · 28th ranked | 55%median 18.8 · 15th ranked |
| EER2 | 38%median 10.6 · 29th ranked | 51%median 11.7 · 17th ranked |
| Heating capacity at 5°F | 34%median 17,400 Btu/h · 28th ranked | 53%median 17,100 Btu/h · 15th ranked |
| Outdoor models | 192 | 92 |
| AHRI certifications | 6,800 | 521 |
Share of models meeting each standard
| Standard | Friedrich | MRCOOL |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 28.1%54 models | 67.4%62 models |
| CEE 2026 Tier 1 (Split ASHP) | 25%48 models | 66.3%61 models |
| CEE Advanced Tier (Split ASHP) | 0.5%1 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 22.4%43 models | 57.6%53 models |
| DOE Cold Climate Heat Pump Challenge | 0.5%1 models | 0%0 models |
| ENERGY STAR Cold Climate | 21.9%42 models | 56.5%52 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Friedrich
- MRCOOL
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Friedrich | MRCOOL |
|---|---|---|
| Ducted, up to 1.5 tons | 20 · index 31% | 10 · index 68% |
| Ducted, 2 tons | 23 · index 32% | 12 · index 57% |
| Ducted, 2.5 to 3 tons | 47 · index 36% | 15 · index 52% |
| Ducted, 3.5 to 4.5 tons | 59 · index 41% | 19 · index 55% |
| Ducted, 5 tons and up | 22 · index 36% | None |
| Non-ducted, up to 1.5 tons | 20 · index 57% | 35 · index 53% |
| Non-ducted, 2 tons | 5 · index 52% | 10 · index 49% |
| Non-ducted, 2.5 to 3 tons | 4 · index 48% | 6 · index 35% |
| Non-ducted, 3.5 to 4.5 tons | 2 · index 47% | 3 · index 61% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | FriedrichCold-climate score, best model | MRCOOLCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 73.8(50 is the typical model of its size class)FPHFR24A3Dwith ducted air handler FPHFA18A3D6 of 22 models qualify · AHRI 217505657 | 80.6(50 is the typical model of its size class) (higher)O-HH-09-HP-C-230C-Owith ducted air handler DUCT-09HP-230B-OAlso listed as O-ES-09-HP-C-230C-O18 of 10 models qualify · AHRI 216032559 |
| Ducted, 2 tons | 70.9(50 is the typical model of its size class)RD17AY24AJVCwith ducted air handler FRH2VY2417STACN5 of 21 models qualify · AHRI 219125948 | 86.5(50 is the typical model of its size class) (higher)O-ES-24-HP-C-230C-O1with ducted air handler O-18-HP-WMAH-235C-O9 of 12 models qualify · AHRI 217447812 |
| Ducted, 2.5 to 3 tons | 78.4(50 is the typical model of its size class) (higher)RD18AY36AJVCwith indoor coil RCFY3621MTANM and furnace FR801V0504A17UHN7 of 47 models qualify · AHRI 216891246 | 77.2(50 is the typical model of its size class)UHP18030-Owith ducted air handler UAH18030 - O9 of 15 models qualify · AHRI 217730329 |
| Ducted, 3.5 to 4.5 tons | 83.9(50 is the typical model of its size class) (higher)FPHFR48A3Dwith ducted air handler FPHFA48A3D11 of 59 models qualify · AHRI 217508872 | 78.1(50 is the typical model of its size class)MULTI6-48HP230C-O12 of 19 models qualify · AHRI 217291702 |
| Ducted, 5 tons and up | 78.1(50 is the typical model of its size class)FRP17AY60AJVCwith indoor coil RCFY6024STANM and furnace FR801V1255A24UHN1 of 22 models qualify · AHRI 218328110 | No models in this size class |
| Non-ducted, up to 1.5 tons | 83.4(50 is the typical model of its size class) (higher)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D16 of 20 models qualify · AHRI 214232408 | 81.6(50 is the typical model of its size class)DIYHH-12-HP-C-230D25-Owith ductless indoor unit DIYCASSETTE12HP-230D25-O22 of 35 models qualify · AHRI 216032550 |
| Non-ducted, 2 tons | 76.9(50 is the typical model of its size class)FPHFR24A3Dwith ductless indoor unit FPHFC24A3D5 of 5 models qualify · AHRI 216626155 | 90.3(50 is the typical model of its size class) (higher)O-ES-24-HP-C-230C-O1with ductless indoor unit O-18-HP-WMAH-233C-O6 of 10 models qualify · AHRI 217447810 |
| Non-ducted, 2.5 to 3 tons | 59.0(50 is the typical model of its size class) (higher)FPHFR36A3Dwith ductless indoor unit FPHSC36A3D3 of 4 models qualify · AHRI 216699608 | 42.4(50 is the typical model of its size class)DIY-MULTI5-36HP230D-O3 of 6 models qualify · AHRI 216032592 |
| Non-ducted, 3.5 to 4.5 tons | 49.8(50 is the typical model of its size class)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models qualify · AHRI 216699609 | 56.7(50 is the typical model of its size class) (higher)MULTI6-48HP230C-O3 of 3 models qualify · AHRI 217291703 |
All-around best
| Size and duct type | FriedrichAll-around score, best model | MRCOOLAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 68.5(50 is the typical model of its size class)FPHFR24A3Dwith ducted air handler FPHFA18A3D21 of 21 models have all five ratings · AHRI 217505657 | 87.1(50 is the typical model of its size class) (higher)O-HH-09-HP-C-230C-Owith ducted air handler DUCT-09HP-230B-OAlso listed as O-ES-09-HP-C-230C-O19 of 10 models have all five ratings · AHRI 216032559 |
| Ducted, 2 tons | 75.5(50 is the typical model of its size class)FRP19AY24AJVCwith ducted air handler FRHMVY3621MEACA21 of 21 models have all five ratings · AHRI 215739593 | 78.9(50 is the typical model of its size class) (higher)O-ES-24-HP-C-230C-O1with ducted air handler O-18-HP-WMAH-235C-O10 of 12 models have all five ratings · AHRI 217447812 |
| Ducted, 2.5 to 3 tons | 84.9(50 is the typical model of its size class) (higher)FRP19AY36AJVCwith ducted air handler FRHMVY3621MEACA34 of 47 models have all five ratings · AHRI 215584440 | 73.5(50 is the typical model of its size class)UHP18030-Owith ducted air handler UAH18030 - O13 of 15 models have all five ratings · AHRI 217730329 |
| Ducted, 3.5 to 4.5 tons | 84.3(50 is the typical model of its size class)FRP19AY48AJVCwith ducted air handler FRHMVY4821SEACA37 of 56 models have all five ratings · AHRI 215584441 | 85.3(50 is the typical model of its size class) (higher)MULTI6-48HP230C-O15 of 19 models have all five ratings · AHRI 217291702 |
| Ducted, 5 tons and up | 70.6(50 is the typical model of its size class)FRP17AY60AJVCwith ducted air handler RH2TY6024STANN16 of 26 models have all five ratings · AHRI 218328406 | No models in this size class |
| Non-ducted, up to 1.5 tons | 85.1(50 is the typical model of its size class) (higher)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D20 of 20 models have all five ratings · AHRI 214232408 | 81.3(50 is the typical model of its size class)O-HH-09-HP-C-230C-Owith ductless indoor unit O-09-HP-WMAH-230C-OAlso listed as O-ES-09-HP-C-230C-O135 of 35 models have all five ratings · AHRI 216032557 |
| Non-ducted, 2 tons | 63.6(50 is the typical model of its size class)FPHSR24A3Bwith ductless indoor unit FAHFW24A3AAlso listed as FPHSR24A3D5 of 5 models have all five ratings · AHRI 214091820 | 78.7(50 is the typical model of its size class) (higher)O-ES-24-HP-C-230C-O1with ductless indoor unit O-18-HP-WMAH-233C-O10 of 10 models have all five ratings · AHRI 217447810 |
| Non-ducted, 2.5 to 3 tons | 64.9(50 is the typical model of its size class)FPHMR27A3D4 of 4 models have all five ratings · AHRI 215792839 | 66.9(50 is the typical model of its size class) (higher)MULTI4-27HP230C-O6 of 6 models have all five ratings · AHRI 217291695 |
| Non-ducted, 3.5 to 4.5 tons | 49.4(50 is the typical model of its size class)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models have all five ratings · AHRI 216699609 | 68.7(50 is the typical model of its size class) (higher)MULTI6-48HP230C-O3 of 3 models have all five ratings · AHRI 217291703 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Friedrich | MRCOOL |
|---|---|---|
| COP at 5°F | beats 97% · 2.40FSHSR18B3BAlso listed as FSHSR18B3DNon-ducted, up to 1.5 tons | beats 98% · 2.44DIY-18-HP-C-230D25-OAlso listed as DIYP-18-HP-C-230DE11-ONon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 100% · 133%FPHFR09A3DDucted, up to 1.5 tons | beats 97% · 112%O-HH-09-HP-C-230C-OAlso listed as O-ES-09-HP-C-230C-O1Ducted, up to 1.5 tons |
| HSPF2 | beats 91% · 9.5FRP17AY60AJVCDucted, 5 tons and up | beats 98% · 13.5O-HH-24-HP-C-230C-ONon-ducted, 2 tons |
| SEER2 | beats 98% · 21.0FRP19AY36AJVCDucted, 2.5 to 3 tons | beats 97% · 25.0MULTI4-27HP230C-ONon-ducted, 2.5 to 3 tons |
| EER2 | beats 96% · 13.0RD18AY36AJVCDucted, 2.5 to 3 tons | beats 95% · 15.4O-HH-09-HP-C-230C-OAlso listed as O-ES-09-HP-C-230C-O1Non-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 96% · 18,600 Btu/hRD18AY24AJVCDucted, up to 1.5 tons | beats 98% · 39,000 Btu/hCENTRAL-36-HP-C-230B00-ODucted, 2.5 to 3 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- Friedrich (median, middle 50%)
- MRCOOL (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Friedrich, 47°F | 44 | 100% | 100% | 100% | 100% | 100% |
| Friedrich, 17°F | 44 | 60% | 65% | 68% | 84% | 92% |
| Friedrich, 5°F | 44 | 57% | 62% | 71% | 74% | 85% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Friedrich, 47°F | 44 | 2.8 | 2.9 | 3.08 | 3.21 | 3.46 |
| Friedrich, 17°F | 44 | 2.07 | 2.2 | 2.4 | 2.5 | 2.51 |
| Friedrich, 5°F | 44 | 1.89 | 1.9 | 2 | 2.09 | 2.1 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| MRCOOL, 47°F | 77 | 100% | 100% | 100% | 100% | 100% |
| MRCOOL, 17°F | 77 | 60% | 67% | 73% | 86% | 94% |
| MRCOOL, 5°F | 77 | 57% | 59% | 68% | 80% | 86% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| MRCOOL, 47°F | 77 | 2.77 | 3 | 3.19 | 3.39 | 3.59 |
| MRCOOL, 17°F | 77 | 1.97 | 2.13 | 2.29 | 2.39 | 2.52 |
| MRCOOL, 5°F | 77 | 1.8 | 1.9 | 2 | 2.09 | 2.18 |
Source: NEEP ccASHP list · as of