Skip to content

Gree vs Trane heat pumps

Measured against models of the same size and duct type, Gree scores higher on 4 of the 6 ratings. Gree has 717 outdoor models, Trane has 363 outdoor models.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Gree and Trane on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Gree scores higher on 4 of the 6 ratings.
  • Gree
  • Trane
  • Other ranked manufacturers
GreeTrane

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingGreeTrane
Efficiency index54% (higher)median — · 12th ranked50% (higher)median — · 19th ranked
COP at 5°F43%median 1.94 · 25th ranked68%median 2.24 · 1st ranked
Capacity retention at 5°F57% (higher)median 77% · 10th ranked43% (higher)median 65% · 24th ranked
HSPF242% (higher)median 9.0 · 24th ranked36% (higher)median 7.5 · 27th ranked
SEER260% (higher)median 20.5 · 7th ranked40% (higher)median 15.5 · 25th ranked
EER260%median 12.0 · 6th ranked66%median 11.7 · 3rd ranked
Heating capacity at 5°F55% (higher)median 16,950 Btu/h · 13th ranked44% (higher)median 21,800 Btu/h · 24th ranked
Outdoor models717363
AHRI certifications5,17384,774

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardGreeTrane
CEE 2025 Tier 1 (Split ASHP)80.9%580 models38.6%140 models
CEE 2026 Tier 1 (Split ASHP)79.8%572 models36.6%133 models
CEE Advanced Tier (Split ASHP)5.6%40 models2.5%9 models
Xcel Energy Colorado cold-climate ASHP (2025)80.1%574 models25.6%93 models
DOE Cold Climate Heat Pump Challenge5.6%40 models2.5%9 models
ENERGY STAR Cold Climate66.1%474 models17.9%65 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 10 groups where both have models
  • Gree
  • Trane
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsNon-ducted, 5 tons and up2.0585 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeGreeTrane
Ducted, up to 1.5 tons96 · index 66%18 · index 46%
Ducted, 2 tons68 · index 57%42 · index 44%
Ducted, 2.5–3 tons120 · index 54%102 · index 49%
Ducted, 3.5–4.5 tons120 · index 58%131 · index 53%
Ducted, 5 tons and up4 · index 60%46 · index 49%
Non-ducted, up to 1.5 tons314 · index 51%15 · index 53%
Non-ducted, 2 tons82 · index 55%4 · index 42%
Non-ducted, 2.5–3 tons81 · index 47%7 · index 56%
Non-ducted, 3.5–4.5 tons47 · index 47%3 · index 63%
Non-ducted, 5 tons and up3 · index 65%2 · index 68%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeGreeCold-climate score, best modelTraneCold-climate score, best model
Ducted, up to 1.5 tons85.5(50 is the typical model of its size class)SPHP-Z-V018BBwith ducted air handler AIRH-Z-V018V06C88 of 95 models qualify · AHRI 21649796292.5(50 is the typical model of its size class) (higher)5TWV0X24A1with indoor coil D(A,C,E)36C3J+TDR and furnace S8V2B060M4PCB5 of 20 models qualify · AHRI 216794262
Ducted, 2 tons77.1(50 is the typical model of its size class)MHPC-H-024BSBwith ducted air handler MDUC-H-024BBB73 of 84 models qualify · AHRI 21649793490.0(50 is the typical model of its size class) (higher)5TCV0X36A1with ducted air handler 5TEMCD04AV31+TDRAlso sold as American Standard 5A5V0X36A115 of 40 models qualify · AHRI 218792275
Ducted, 2.5–3 tons77.4(50 is the typical model of its size class)SPHP-Z-V036BBwith ducted air handler AIRH-Z-V036V12C62 of 105 models qualify · AHRI 21649796584.6(50 is the typical model of its size class) (higher)5TWV8X36A1with indoor coil D(A,C,E)36C3J+TDR and furnace S8V2C080M5PCB24 of 102 models qualify · AHRI 216797087
Ducted, 3.5–4.5 tons88.7(50 is the typical model of its size class)GUD60W2/NHE-D(U)with ducted air handler HND60A/NHA-O79 of 120 models qualify · AHRI 21804337193.0(50 is the typical model of its size class) (higher)5TWV0X48A1with indoor coil D(A,C,E)60B4J+TDR and furnace S9V2D120U5PSC+LRP38 of 131 models qualify · AHRI 216794596
Ducted, 5 tons and up69.3(50 is the typical model of its size class)TMV-V60WL/NHC-T(U)2 of 4 models qualify · AHRI 21677230681.1(50 is the typical model of its size class) (higher)3TXK2260AF00HAAAlso listed as 3TVHS060SF000AA2 of 46 models qualify · AHRI 218451025
Non-ducted, up to 1.5 tons89.5(50 is the typical model of its size class) (higher)MHPC-H-009BSBwith ductless indoor unit MCON-H-009BBB296 of 314 models qualify · AHRI 21649793868.6(50 is the typical model of its size class)M5THM2318A12NA*15 of 15 models qualify · AHRI 218067082
Non-ducted, 2 tons84.5(50 is the typical model of its size class) (higher)MHPC-H-024BSBwith ductless indoor unit MWAL-H-024BBB68 of 82 models qualify · AHRI 21649791937.7(50 is the typical model of its size class)M5THS2324A11NAAwith ductless indoor unit M5MHWUN24A1N0AAAlso listed as M5THS2324A11NA4 of 4 models qualify · AHRI 215385437
Non-ducted, 2.5–3 tons77.2(50 is the typical model of its size class) (higher)GWHD(36)ND6MOAlso sold as Tosot TM36H32MO, Kinghome KM36X6O, Tosot MZ-COSMO36/O, Tosot TM36D6MO and 6 more; also listed as MUL36HP230V1R32AO, GS4M36HP230V1MO, GWHD(36)ND6CO74 of 81 models qualify · AHRI 21493158973.8(50 is the typical model of its size class)3TVHS036SF000AAAlso listed as 3TXK2224AF00HAA, 3TXK2236AF00HAA5 of 7 models qualify · AHRI 218451026
Non-ducted, 3.5–4.5 tons66.5(50 is the typical model of its size class)GWHD(42)ND6MOAlso sold as Tosot TM42H32MO, Kinghome KM42X6O, Tosot TM42D6MO, Tosot TMSCI7H4R42 and 5 more; also listed as MUL42HP230V1R32AO, GS5M42HP230V1MO31 of 47 models qualify · AHRI 21493159067.2(50 is the typical model of its size class) (higher)3TVHS048SF000AAAlso listed as 3TXK2248AF00HAA3 of 3 models qualify · AHRI 218451027
Non-ducted, 5 tons and up53.2(50 is the typical model of its size class)GMV-V60WL/NHC-T(U)Also sold as Tosot TMV-V60WL/NHC-T(U)2 of 3 models qualify · AHRI 21677224964.1(50 is the typical model of its size class) (higher)3TVHS060SF000AAAlso listed as 3TXK2260AF00HAA2 of 2 models qualify · AHRI 218451028

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeGreeAll-around score, best modelTraneAll-around score, best model
Ducted, up to 1.5 tons83.7(50 is the typical model of its size class)GS09HP230V1PUOwith ducted air handler GS09HP230V1DAI95 of 95 models have all five ratings · AHRI 21863637784.4(50 is the typical model of its size class) (higher)5TWV0X24A1with indoor coil D(A,C,E)36C3J+TDR and furnace *UHMB060CCV3+LRP17 of 17 models have all five ratings · AHRI 216794699
Ducted, 2 tons82.9(50 is the typical model of its size class)A7CP21V24P-**Awith ducted air handler 7AH2AE24PX-75 of 75 models have all five ratings · AHRI 21746595386.7(50 is the typical model of its size class) (higher)5TCV0X36A1with ducted air handler 5TEMCD04AV31+TDRAlso sold as American Standard 5A5V0X36A131 of 31 models have all five ratings · AHRI 218792275
Ducted, 2.5–3 tons79.8(50 is the typical model of its size class)A7CP21V36P-**Awith ducted air handler 7AH1AV42PX-113 of 113 models have all five ratings · AHRI 21746590688.5(50 is the typical model of its size class) (higher)5TWV0X36A1with indoor coil 5PX*D010AS3 and furnace S8V2D120M5PDBAlso sold as American Standard 5A6V0X36A171 of 107 models have all five ratings · AHRI 216453109
Ducted, 3.5–4.5 tons85.1(50 is the typical model of its size class)MHPC-H-048BMB120 of 120 models have all five ratings · AHRI 21649795188.9(50 is the typical model of its size class) (higher)5TWV0X48A1with indoor coil D(A,C,E)60B4J+TDR and furnace L8V1C100U5VSB+LRP102 of 138 models have all five ratings · AHRI 216794476
Ducted, 5 tons and up66.7(50 is the typical model of its size class)BH714S60P-**Awith ducted air handler BAH7V60PT-5 of 5 models have all five ratings · AHRI 21637130374.7(50 is the typical model of its size class) (higher)3TXK2260AF00HAAAlso listed as 3TVHS060SF000AA9 of 46 models have all five ratings · AHRI 218451025
Non-ducted, up to 1.5 tons92.6(50 is the typical model of its size class) (higher)MHPC-H-009BSBwith ductless indoor unit MCON-H-009BBB310 of 314 models have all five ratings · AHRI 21649793872.2(50 is the typical model of its size class)M5THM2318A12NA*15 of 15 models have all five ratings · AHRI 218067082
Non-ducted, 2 tons86.8(50 is the typical model of its size class) (higher)MHPC-H-024BSBwith ductless indoor unit MWAL-H-024BBB78 of 82 models have all five ratings · AHRI 21649791948.8(50 is the typical model of its size class)M5THS2324A11NAAwith ductless indoor unit M5MHWUN24A1N0AAAlso listed as M5THS2324A11NA4 of 4 models have all five ratings · AHRI 215385437
Non-ducted, 2.5–3 tons75.1(50 is the typical model of its size class)GMV-V36WL/NHC-T(U)Also sold as Tosot TMV-V36WL/NHC-T(U)81 of 81 models have all five ratings · AHRI 21712344376.2(50 is the typical model of its size class) (higher)3TVHS036SF000AAAlso listed as 3TXK2224AF00HAA, 3TXK2236AF00HAA7 of 7 models have all five ratings · AHRI 218451026
Non-ducted, 3.5–4.5 tons68.6(50 is the typical model of its size class)MHPC-H-048BMB45 of 47 models have all five ratings · AHRI 21649795273.9(50 is the typical model of its size class) (higher)3TVHS048SF000AAAlso listed as 3TXK2248AF00HAA3 of 3 models have all five ratings · AHRI 218451027
Non-ducted, 5 tons and up68.8(50 is the typical model of its size class) (higher)GMV-V60WL/NHC-T(U)Also sold as Tosot TMV-V60WL/NHC-T(U)3 of 3 models have all five ratings · AHRI 21677224967.9(50 is the typical model of its size class)3TVHS060SF000AAAlso listed as 3TXK2260AF00HAA2 of 2 models have all five ratings · AHRI 218451028

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingGreeTrane
COP at 5°Fbeats 99% · 2.40GMV-V36WL/NHC-T(U)Also sold as Tosot TMV-V36WL/NHC-T(U)Non-ducted, 2.5–3 tonsbeats 100% · 3.205TWR4036A1Ducted, 2.5–3 tons
Capacity retention at 5°Fbeats 99% · 126%GK-H02TC/NHA-D(U)Also sold as Ac Pro PKHP-X-024VBC, Tosot TK-H02TC/NHA-D(U)Ducted, 2 tonsbeats 100% · 136%5A6H7036A1Ducted, 2.5–3 tons
HSPF2beats 98% · 10.8SPHP-Z-V030BBDucted, 2.5–3 tonsbeats 100% · 13.53TXK2224AF00HAAAlso listed as 3TXK2236AF00HAA, 3TVHS036SF000AADucted, 2.5–3 tons
SEER2beats 100% · 24.5GWH18AVEXF-D6DNA1A/OAlso sold as Kinghome KW18XQ29SDO, Tosot TW18HAY32A1DO, Tosot TW18HAY32A1DOC, Tosot TWH18AD32AO and 1 more; also listed as GWH18AVEXF-D6DNA1B/ODucted, up to 1.5 tonsbeats 99% · 21.65TWV0X36A1Also sold as American Standard 5A6V0X36A1Ducted, 2.5–3 tons
EER2beats 100% · 14.5BH714S18P-**ADucted, up to 1.5 tonsbeats 99% · 14.43TVHS036SF000AAAlso listed as 3TXK2224AF00HAA, 3TXK2236AF00HAANon-ducted, 2.5–3 tons
Heating capacity at 5°Fbeats 99% · 30,300 Btu/hGK-H02TC/NHA-D(U)Also sold as Ac Pro PKHP-X-024VBC, Tosot TK-H02TC/NHA-D(U)Ducted, 2 tonsbeats 100% · 27,200 Btu/h5TWV0X24A1Ducted, up to 1.5 tons

More comparisons