Skip to content

Xcel Energy Colorado cold-climate ASHP (2025): 6,518 qualifying heat pumps

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

New to heat pump ratings? The Simple view explains them in plain words →

Xcel EnergyData as of updated · sources

Share of models
52.8%
Qualifying models
6,518
Qualifying certifications
189,428
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Where the thresholds fall

Every model's representative certification on each rating Xcel CC checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F11,222 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+40 above12 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4012
1.40 to under 1.5079
1.50 to under 1.60176
1.60 to under 1.70335
1.70 to under 1.801,180
1.80 to under 1.902,238
1.90 to under 2.001,351
2.00 to under 2.102,428
2.10 to under 2.201,325
2.20 to under 2.30777
2.30 to under 2.40512
2.40 to under 2.50260
2.50 to under 2.60215
2.60 to under 2.70132
2.70 to under 2.8080
2.80 to under 2.9051
2.90 to under 3.0031
3.00 and above40
Baseline: median2.00
Baseline: Xcel 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F11,157 rated models · median 72%65% of rated models reach 70% on this rating alone.
+40 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%28
35 to under 40%337
40 to under 45%467
45 to under 50%519
50 to under 55%566
55 to under 60%526
60 to under 65%684
65 to under 70%763
70 to under 75%2,400
75 to under 80%1,156
80 to under 85%799
85 to under 90%375
90 to under 95%720
95 to under 100%582
100 to under 105%758
105 to under 110%151
110 to under 115%148
115 to under 120%27
120 to under 125%41
125 to under 130%19
130% and above40
Baseline: median72%
Baseline: Xcel 70%70%

Source: AHRI Directory · as of

SEER212,331 rated models · median 18.0At least 71% of rated models reach 15.2 (the lowest path) on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.014
13.0 to under 13.5900
13.5 to under 14.0338
14.0 to under 14.51,004
14.5 to under 15.0192
15.0 to under 15.51,100
15.5 to under 16.0284
16.0 to under 16.5624
16.5 to under 17.0188
17.0 to under 17.5848
17.5 to under 18.0214
18.0 to under 18.5681
18.5 to under 19.0393
19.0 to under 19.5745
19.5 to under 20.0182
20.0 to under 20.5917
20.5 to under 21.0162
21.0 to under 21.5783
21.5 to under 22.0162
22.0 to under 22.5508
22.5 to under 23.0197
23.0 to under 23.5661
23.5 to under 24.0111
24.0 to under 24.5294
24.5 to under 25.0151
25.0 to under 25.5286
25.5 to under 26.075
26.0 to under 26.539
26.5 to under 27.019
27.0 to under 27.561
27.5 to under 28.022
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.022
30.0 to under 30.523
30.5 and above54
Baseline: median18.0
Baseline: Ducted 15.215.2
Baseline: Non-ducted 1616.0

Source: AHRI Directory · as of

EER212,327 rated models · median 11.597% of rated models reach 9 (the lowest path) on this rating alone.
+31 above2 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.02
8.0 to under 8.594
8.5 to under 9.0214
9.0 to under 9.5703
9.5 to under 10.0831
10.0 to under 10.5881
10.5 to under 11.01,359
11.0 to under 11.51,679
11.5 to under 12.01,904
12.0 to under 12.51,869
12.5 to under 13.0951
13.0 to under 13.5914
13.5 to under 14.0232
14.0 to under 14.5275
14.5 to under 15.0114
15.0 to under 15.5180
15.5 to under 16.05
16.0 to under 16.531
16.5 to under 17.023
17.0 to under 17.535
17.5 and above31
Baseline: median11.5
Baseline: Non-ducted 99.0
Baseline: Ducted 1010.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting Xcel CC, by size
Show the data as a table
Share of models meeting Xcel CC, by size
GroupQualifying share
Up to 1.5 tons61.6% · 2,906 of 4,716
2 tons60.8% · 1,062 of 1,748
2.5–3 tons50.3% · 1,371 of 2,726
3.5–4.5 tons42.1% · 1,130 of 2,687
5 tons and up10.7% · 49 of 458

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted31.9%1,934 / 6,057
Non-ducted63%2,575 / 4,089
Ducted and non-ducted91.8%2,009 / 2,189

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree574 of 71780.1%
Midea381 of 54669.8%
Carrier223 of 81627.3%
BlueRidge131 of 19268.2%
TCL128 of 17772.3%
Lennox121 of 33735.9%
Ephoca120 of 38231.4%
Daikin117 of 39429.7%
Rheem115 of 34133.7%
Hisense110 of 16168.3%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting Xcel Energy Colorado cold-climate ASHP (2025), page 79 of 261
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
1951ESHEA18C2AN1ELIOS · ESH Serieswith ducted air handler GDHRA18C2AS1ELIOS1.5 tons17,500 Btu/h · Ducted and non-ducted2.4171%11.320.0CEE 25CEE 26XcelES CC3216046628
1952ESHEA24C2AN1ELIOS · ESH Serieswith ductless indoor unit GQHRA24C2AS1ELIOS2 tons24,000 Btu/h · Ducted and non-ducted2.3074%10.522.0CEE 25CEE 26XcelES CC2216046621
1953ESHEA24R2AN*ELIOS · ESH Serieswith ducted air handler GCHMA24RAASELIOS2 tons24,000 Btu/h · Ducted1.8076%9.016.0CEE 25CEE 26XcelES CC2218736526
1954ESHEA24R2AN1ELIOS · ESH Serieswith ducted air handler GGHLA24R4AS1ELIOS2 tons24,000 Btu/h · Ducted1.9678%10.417.4CEE 25CEE 26XcelES CC3217177263
1955ESHEA36R2AN1ELIOS · ESH Serieswith ducted air handler GUHMA36RBAS1ELIOS3 tons36,000 Btu/h · Ducted2.0076%8.514.7CEE 25CEE 26XcelES CC4216684116
1956ESHMA09C2AN1ELIOS · ESH Serieswith ductless indoor unit EWHMA09C2AS1ELIOS1 ton9,000 Btu/h · Non-ducted1.8096%12.526.0CEE 25CEE 26XcelES CC1216046613
1957ESHMA12C2AN1ELIOS · ESH Serieswith ductless indoor unit EWHMA12C2AS1ELIOS1 ton12,000 Btu/h · Non-ducted1.8096%10.524.0CEE 25CEE 26XcelES CC1216046614
1958ESHMA18C2AN1ELIOS · ESH Serieswith ductless indoor unit EWHMA18C2AS1ELIOS1.5 tons18,000 Btu/h · Non-ducted2.00100%10.821.7CEE 25CEE 26XcelES CC1216046615
1959ESHMA18R2AN*ELIOS · ESH Serieswith ducted air handler GCHMA24RAASELIOS1.5 tons18,000 Btu/h · Ducted2.0695%9.516.1CEE 25CEE 26XcelES CC2218736521
1960ESHMA18R2AN1ELIOS · ESH Serieswith ducted air handler GCHMA24RBAS1ELIOS1.5 tons18,000 Btu/h · Ducted2.0695%9.516.1CEE 25CEE 26XcelES CC2216623472
1961ESHMA24C2AN1ELIOS · ESH Serieswith ductless indoor unit EWHMA24C2AS1ELIOS2 tons23,000 Btu/h · Non-ducted2.0092%13.322.3CEE 25CEE 26XcelES CC1216046616
1962ESHMA24R2AN*ELIOS · ESH Serieswith ducted air handler GCHMA24RAASELIOS2 tons24,000 Btu/h · Ducted1.8084%9.516.0CEE 25CEE 26XcelES CC2218736522
1963ESHMA24R2AN1ELIOS · ESH Serieswith ducted air handler EAHMA24R4AS1ELIOS2 tons23,000 Btu/h · Ducted1.8790%10.018.3CEE 25CEE 26XcelES CC3216046597
1964ESHMA30R2AN1ELIOS · ESH Serieswith ducted air handler EAHMA30R4AS1ELIOS2.5 tons30,000 Btu/h · Ducted1.9696%10.016.8CEE 25CEE 26XcelES CC5216046598
1965ESHMA33C2AN1ELIOS · ESH Serieswith ductless indoor unit EWHMA33C2AS1ELIOS3 tons33,000 Btu/h · Non-ducted1.9196%10.520.0CEE 25CEE 26XcelES CC1216046617
1966ESHMA48R2AN1ELIOS · ESH Serieswith ducted air handler EAHMA48R4AS1ELIOS4 tons48,000 Btu/h · Ducted1.9092%9.516.5CEE 25CEE 26XcelES CC2216046600
1967ESHMA60R2AN1ELIOS · ESH Serieswith ducted air handler GCHMA60RDAS1ELIOS4 tons47,000 Btu/h · Ducted1.8374%8.115.2CEE 25CEE 26XcelES CC2216623476
1968ESHMB36R2AN1ELIOS · ESH Serieswith ducted air handler EAHMA36R4AS1ELIOS3 tons36,000 Btu/h · Ducted1.90105%10.317.4CEE 25CEE 26XcelES CC5216618899
1969ESHUA36R2AN1ELIOS · ESH Serieswith ductless indoor unit GQHLA36R2AS1ELIOS3 tons36,000 Btu/h · Ducted and non-ducted2.2070%10.320.0CEE 25CEE 26XcelES CC3216046622
1970ESHUA48R2AN1ELIOS · ESH Serieswith ductless indoor unit GQHLA48R2AS1ELIOS4 tons48,000 Btu/h · Ducted and non-ducted2.1181%9.919.0CEE 25CEE 26XcelES CC3216046623
1971EXHSA1832AN1ELIOS · EXH SeriesELIOS1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.3077%10.020.0CEE 25CEE 26XcelES CC3216505501
1972EXHSA2742AV1ELIOS · EXH SeriesELIOS2 tons26,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.523.0CEE 25CEE 26XcelES CC3216046639
1973EXHSA3652AV1ELIOS · EXH SeriesELIOS3 tons35,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%10.023.1CEE 25CEE 26XcelES CC3216046642
1974EXHSA4862AV1ELIOS · EXH SeriesELIOS4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1075%10.021.3CEE 25CEE 26XcelES CC3216046645
1975EXHZA1832AV1ELIOS · EXH SeriesELIOS1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0090%10.021.0CEE 25CEE 26XcelES CC3217900386

Explore qualifying models by COP at 5°F