Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
DOE Cold Climate Heat Pump Challenge: 322 qualifying heat pumps
Rating thresholds from the DOE Residential Cold Climate Heat Pump Technology Challenge.
New to heat pump ratings? The Simple view explains them in plain words →
U.S. Department of EnergyData as of updated · sources
- Share of models
- 2.6%
- Qualifying models
- 322
- Qualifying certifications
- 1,066
- Paths
- 1
Criteria
| Path | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|
| Challenge specification | ≥ 8.5 | ≥ 2.1 | ≥ 100% |
Source: U.S. Department of Energy
Where the thresholds fall
Every model's representative certification on each rating DOE CCHP checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 12 |
| 1.40 to under 1.50 | 79 |
| 1.50 to under 1.60 | 176 |
| 1.60 to under 1.70 | 335 |
| 1.70 to under 1.80 | 1,180 |
| 1.80 to under 1.90 | 2,237 |
| 1.90 to under 2.00 | 1,350 |
| 2.00 to under 2.10 | 2,426 |
| 2.10 to under 2.20 | 1,325 |
| 2.20 to under 2.30 | 778 |
| 2.30 to under 2.40 | 511 |
| 2.40 to under 2.50 | 260 |
| 2.50 to under 2.60 | 215 |
| 2.60 to under 2.70 | 132 |
| 2.70 to under 2.80 | 80 |
| 2.80 to under 2.90 | 51 |
| 2.90 to under 3.00 | 31 |
| 3.00 and above | 40 |
| Baseline: median | 2.00 |
| Baseline: DOE CCHP 2.1 | 2.10 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 51 |
| 30 to under 35% | 28 |
| 35 to under 40% | 337 |
| 40 to under 45% | 467 |
| 45 to under 50% | 520 |
| 50 to under 55% | 565 |
| 55 to under 60% | 526 |
| 60 to under 65% | 684 |
| 65 to under 70% | 763 |
| 70 to under 75% | 2,400 |
| 75 to under 80% | 1,157 |
| 80 to under 85% | 798 |
| 85 to under 90% | 375 |
| 90 to under 95% | 719 |
| 95 to under 100% | 580 |
| 100 to under 105% | 757 |
| 105 to under 110% | 151 |
| 110 to under 115% | 148 |
| 115 to under 120% | 27 |
| 120 to under 125% | 41 |
| 125 to under 130% | 19 |
| 130% and above | 40 |
| Baseline: median | 72% |
| Baseline: DOE CCHP 100% | 100% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 41 |
| 6.5 to under 6.8 | 983 |
| 6.8 to under 7.0 | 64 |
| 7.0 to under 7.3 | 528 |
| 7.3 to under 7.5 | 15 |
| 7.5 to under 7.8 | 1,111 |
| 7.8 to under 8.0 | 383 |
| 8.0 to under 8.3 | 720 |
| 8.3 to under 8.5 | 177 |
| 8.5 to under 8.8 | 1,449 |
| 8.8 to under 9.0 | 196 |
| 9.0 to under 9.3 | 1,501 |
| 9.3 to under 9.5 | 132 |
| 9.5 to under 9.8 | 1,369 |
| 9.8 to under 10.0 | 306 |
| 10.0 to under 10.3 | 1,626 |
| 10.3 to under 10.5 | 228 |
| 10.5 to under 10.8 | 602 |
| 10.8 to under 11.0 | 80 |
| 11.0 to under 11.3 | 294 |
| 11.3 to under 11.5 | 59 |
| 11.5 to under 11.8 | 122 |
| 11.8 to under 12.0 | 21 |
| 12.0 to under 12.3 | 27 |
| 12.3 to under 12.5 | 2 |
| 12.5 to under 12.8 | 92 |
| 12.8 to under 13.0 | 0 |
| 13.0 to under 13.3 | 23 |
| 13.3 to under 13.5 | 9 |
| 13.5 to under 13.8 | 43 |
| 13.8 to under 14.0 | 34 |
| 14.0 and above | 62 |
| Baseline: median | 9.0 |
| Baseline: DOE CCHP 8.5 | 8.5 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons3.6% · 171 of 4,712
- 2 tons2.2% · 38 of 1,747
- 2.5–3 tons2.1% · 58 of 2,722
- 3.5–4.5 tons2% · 53 of 2,687
- 5 tons and up0.4% · 2 of 458
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 3.6% · 171 of 4,712 |
| 2 tons | 2.2% · 38 of 1,747 |
| 2.5–3 tons | 2.1% · 58 of 2,722 |
| 3.5–4.5 tons | 2% · 53 of 2,687 |
| 5 tons and up | 0.4% · 2 of 458 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 1.9% | 114 / 6,060 |
| Non-ducted | 2.4% | 97 / 4,081 |
| Ducted and non-ducted | 5.1% | 111 / 2,185 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 276GMRSHT36AS4TGM · M-Series | TGM | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 100% | 10.0 | 21.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 217284813 |
| 277THP-GUD60W2/NHE-D(U)The Heat Pumpwith ducted air handler THP-GUD60AH2/G-D(U) | The Heat Pump | 4.5 tons53,000 Btu/h · Ducted | 2.10 | 100% | 10.5 | 18.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 218338362 |
| 2785A5V0X36A1AMERICAN STANDARD · Platinum 20 Cold Climate Heat Pumpwith ducted air handler 5TEMCD04AV31+TDR | Trane | 2 tons26,200 Btu/h · Ducted | 2.27 | 107% | 10.3 | 20.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 218792276 |
| 2795A5V0X61A1AMERICAN STANDARD · Platinum 20 Cold Climate Heat Pumpwith ducted air handler 5TEMCD07BV51+TDR | Trane | 4 tons48,000 Btu/h · Ducted | 2.22 | 100% | 10.0 | 18.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 218792282 |
| 2805A6V8X24A1AMERICAN STANDARDwith indoor coil D(A,C,E)24B4J+TDR and furnace S8V2A040M3PCB | Trane | 1.5 tons19,500 Btu/h · Ducted | 2.91 | 99% | 8.5 | 17.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 143 | 217117188 |
| 2815TCV0X36A1TRANE · 20 TruComfort Variable Speed Cold Climate Heat Pumpwith ducted air handler 5TEMCD04AV31+TDR | Trane | 2 tons26,200 Btu/h · Ducted | 2.27 | 107% | 10.3 | 20.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 218792275 |
| 2825TCV0X61A1TRANE · 20 TruComfort Variable Speed Cold Climate Heat Pumpwith ducted air handler 5TEMCD07BV51+TDR | Trane | 4 tons48,000 Btu/h · Ducted | 2.22 | 100% | 10.0 | 18.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 218792281 |
| 2835TWV0X24A1TRANEwith indoor coil D(A,C,E)36C3J+TDR and furnace S8V2B060M4PCB | Trane | 1.5 tons19,800 Btu/h · Ducted | 2.99 | 122% | 10.0 | 21.2 | CEE 25CEE 26CEE AdvXcelDOEES CC | 185 | 216794262 |
| 2845TWV0X48A1TRANEwith indoor coil D(A,C,E)60B4J+TDR and furnace S9V2D120U5PSC+LRP | Trane | 3.5 tons41,500 Btu/h · Ducted | 2.81 | 108% | 9.5 | 20.2 | CEE 25CEE 26CEE AdvXcelDOEES CC | 207 | 216794596 |
| 2855TWV8X36A1TRANEwith indoor coil D(A,C,E)36C3J+TDR and furnace S8V2C080M5PCB | Trane | 2.5 tons29,800 Btu/h · Ducted | 2.85 | 115% | 8.5 | 18.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 255 | 216797087 |
| 2865TWV8X48A1TRANEwith indoor coil D(A,C,E)48C3J+TDR and furnace S8V2C080M5PCB | Trane | 4 tons45,000 Btu/h · Ducted | 2.89 | 115% | 7.8 | 18.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 215 | 216797145 |
| 287WLWHD(36)ND6MOTRUENORTH | TRUENORTH | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 100% | 10.0 | 21.0 | CEE 25CEE 26CEE AdvXcelDOE | 3 | 218593166 |
| 288OUS06H/O6S4PTRUST AIR CONDITIONERS · OUS Serieswith ductless indoor unit IUMC106H/I61P | TRUST AIR CONDITIONERS | 0.5 tons6,500 Btu/h · Non-ducted | 2.40 | 109% | 12.0 | 22.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 217678094 |
| 289UCHA-24HDCSN2UTL · SIDE-DISCHARGEwith ducted air handler UCHA-24SHDCALN2 | UTL | 2 tons24,000 Btu/h · Ducted | 2.20 | 100% | 9.5 | 18.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 218694268 |
| 290UCHA-24HDCSN4UTL · SIDE-DISCHARGEwith ducted air handler UCHA-24HDCN4 | UTL | 2 tons24,000 Btu/h · Ducted | 2.20 | 100% | 9.5 | 18.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 217739010 |
| 291UCHA-24HDCTRN2UTL · TOP-DISCHARGEwith ducted air handler UCHA-24HDCALN2 | UTL | 2 tons24,000 Btu/h · Ducted | 2.30 | 100% | 10.2 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 218472797 |
| 292D5CSHAH06AAKViessmann · D5C Serieswith ductless indoor unit D5FSHAH06XAK | Viessmann | 0.5 tons6,000 Btu/h · Non-ducted | 2.40 | 110% | 14.8 | 25.7 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 217178781 |
| 293D5CUHAH18AAKViessmann · D5C Serieswith ducted air handler D5FUHAH24XAK | Viessmann | 1.5 tons18,000 Btu/h · Ducted | 2.12 | 103% | 10.2 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 5 | 217178772 |
| 294VHP-UCHA-24HDCSN4VillaTherm · SIDE-DISCHARGEwith ducted air handler VAH-UCHA-24HDCSN4 | VillaTherm | 2 tons24,000 Btu/h · Ducted | 2.20 | 100% | 9.5 | 18.5 | CEE 25CEE 26CEE AdvXcelDOE | 1 | 217753628 |
| 295VHP-UCHA-24HDCT-AVillaTherm · SPLIT AHUwith ducted air handler VAH-UCHA-24SHDCALN2 | VillaTherm | 2 tons24,000 Btu/h · Ducted | 2.30 | 100% | 10.2 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 5 | 218696917 |
| 296VHPSD-UCHA-24HDCSN*VillaTherm · SIDE-DISCHARGEwith ducted air handler VAH-UCHA-24SHDCALN2 | VillaTherm | 2 tons24,000 Btu/h · Ducted | 2.20 | 100% | 9.5 | 18.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 218731834 |
| 297VHPSD-UCHA-24HDCSN4VillaTherm · SIDE-DISCHARGEwith ducted air handler VAHSD-UCHA-24HDCSN4 | VillaTherm | 2 tons24,000 Btu/h · Ducted | 2.20 | 100% | 9.5 | 18.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 217889246 |
| 298UCHA-24HDCSN4VKIN · SIDE-DISCHARGEwith ducted air handler UCHA-24HDCN4 | VKIN | 2 tons24,000 Btu/h · Ducted | 2.20 | 100% | 9.5 | 18.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 218385960 |
| 299WOS-06PRE/230Wells · WOS Serieswith ducted air handler WIDL-06MOC/230 | Wells | 0.5 tons6,500 Btu/h · Ducted and non-ducted | 2.41 | 98% | 13.8 | 21.4 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215864077 |
| 300AUHW09KR32-OWILLIS · ULTIMAwith ductless indoor unit AUHW09KR32-I | WILLIS | 1 ton9,100 Btu/h · Ducted and non-ducted | 2.11 | 108% | 11.2 | 30.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 6 | 217007963 |