Ranked by Capacity retention at 5°F only, for their size and type
Heating capacity at 5°F as a percentage of rated heating capacity at 47°F. This board ranks by that one rating; it is not the overall cold-climate verdict, which is the cold-climate board. Small units rate higher than large ones and ductless units higher than ducted ones, so this board does not rank raw numbers across sizes. Each model is ranked by the share of comparable models (same size and duct type) it beats, one model per manufacturer. Only manufacturers with a QMID (IRS Qualified Manufacturer ID) on file are ranked.
New to heat pump ratings? The Simple view explains them in plain words →
LeaderboardsData as of updated · sources
Top 25 ranked by Capacity retention at 5°F only, against their peers
- All models of the group (shape)
- Leaderboard model
- Median and middle 50% / 80%
- Standard threshold
Show the data as a table
| Peer group | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 1,785 | 53% | 71% | 74% | 90% | 100% |
| Ducted, 2 tons | 1,090 | 44% | 59% | 75% | 86% | 96% |
| Ducted, 2.5–3 tons | 1,911 | 41% | 53% | 70% | 90% | 100% |
| Ducted, 3.5–4.5 tons | 2,228 | 41% | 51% | 71% | 84% | 98% |
| Ducted, 5 tons and up | 320 | 42% | 45% | 53% | 67% | 72% |
| Non-ducted, up to 1.5 tons | 3,410 | 61% | 70% | 76% | 91% | 100% |
| Non-ducted, 2 tons | 853 | 62% | 70% | 74% | 83% | 95% |
| Non-ducted, 2.5–3 tons | 1,085 | 64% | 70% | 74% | 99% | 100% |
| Non-ducted, 3.5–4.5 tons | 568 | 66% | 75% | 81% | 90% | 96% |
| Non-ducted, 5 tons and up | 85 | 63% | 63% | 65% | 71% | 83% |
Source: AHRI Directory · as of
| # · Outdoor model | Manufacturer | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. | Compared with | Beats |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 137MPRAQ06AA3CARRIER · 45M Serieswith ductless indoor unit 45MPHAQ06XA3Also sold as Midea 37MPRAQ06AA3, MDV MOX430-06HFN10-M1H | Carrier | 0.5 tons6,000 Btu/h · Non-ducted | 150% | 2.00 | 15.6 | 35.1 | 17.5 | 13,500 | CEE 25CEE 26XcelES CC | 5 | 215413141 | Non-ducted, up to 1.5 tons3,410 models | 100% |
| 2D5CPRAH06AAKMIDEA · D5F Serieswith ductless indoor unit D5FPHAH06XAKAlso sold as Arcoaire D5CPRAH06AAK | Midea | 0.5 tons6,000 Btu/h · Non-ducted | 150% | 2.00 | 15.6 | 33.1 | 16.5 | 13,500 | CEE 25CEE 26XcelES CC | 1 | 215413295 | Non-ducted, up to 1.5 tons3,410 models | 100% |
| 3BMS635SHYCBLUERIDGE · BMS Serieswith ductless indoor unit BMS635SHYWAlso listed as BXS6A06UC0 | BlueRidge | 0.5 tons6,000 Btu/h · Non-ducted | 150% | 2.00 | 15.6 | 35.0 | 17.4 | 13,500 | CEE 25CEE 26XcelES CC | 1 | 215853907 | Non-ducted, up to 1.5 tons3,410 models | 100% |
| 4ML06HP230CALH-OMAINLINE · ML Serieswith ductless indoor unit ML06HP230CALH-I | Rheem | 0.5 tons6,000 Btu/h · Non-ducted | 150% | 2.00 | 15.6 | 35.0 | 17.4 | 13,500 | CEE 25CEE 26XcelES CC | 2 | 215864344 | Non-ducted, up to 1.5 tons3,410 models | 100% |
| 5A-ZHP06SA-1COMFORT-AIRE · A-ZHP Serieswith ductless indoor unit B-ZHP06SA-1 | Lennox | 0.5 tons6,000 Btu/h · Non-ducted | 150% | 2.00 | 15.6 | 35.0 | 17.4 | 13,500 | CEE 25CEE 26XcelES CC | 2 | 216097116 | Non-ducted, up to 1.5 tons3,410 models | 100% |
| 6AVW-60F3DAH2Hisense | Hisense | 5 tons60,000 Btu/h · Ducted | 100% | 2.10 | 10.1 | 17.0 | 10.5 | 63,000 | CEE 25CEE 26CEE AdvXcelDOE | 3 | 216618253 | Ducted, 5 tons and up302 models | 100% |
| 7CHV6-RS60URBMHHCooper & Hunter | Cooper&Hunter | 5 tons60,000 Btu/h · Ducted | 100% | 2.10 | 10.1 | 17.0 | 10.5 | 63,000 | CEE 25CEE 26CEE AdvXcelDOE | 3 | 217026558 | Ducted, 5 tons and up302 models | 100% |
| 8YRACXJ24WHBAYORK · Y800with ductless indoor unit YRAKXJ24PHBA | York | 2 tons22,000 Btu/h · Non-ducted | 123% | 1.98 | 11.0 | 21.0 | 12.5 | 27,000 | CEE 25CEE 26XcelES CC | 1 | 218452761 | Non-ducted, 2 tons884 models | 100% |
| 9KUSXA181ALGwith ducted air handler MSVT24***852FAA | LG | 1.5 tons17,400 Btu/h · Ducted | 137% | 2.00 | 10.0 | 18.0 | 13.5 | 23,800 | CEE 25CEE 26XcelES CC | 47 | 217581954 | Ducted, up to 1.5 tons1,820 models | 100% |
| 10FPHFR09A3DFRIEDRICH · Floating Air Pro Xwith ducted air handler FPHFD09A3DAlso sold as Rheem FPHFR09A3D | Friedrich | 1 ton9,000 Btu/h · Ducted | 133% | 1.80 | 9.5 | 19.5 | 11.7 | 12,000 | CEE 25CEE 26XcelES CC | 3 | 216626150 | Ducted, up to 1.5 tons1,820 models | 100% |
| 11QOS09H2BH0AInnovair · Q4+with ducted air handler QDL09H2BHWA | Innovair | 1 ton9,000 Btu/h · Ducted | 133% | 1.80 | 9.5 | 19.5 | 11.7 | 12,000 | CEE 25CEE 26XcelES CC | 5 | 216626158 | Ducted, up to 1.5 tons1,820 models | 100% |
| 125A6H7036A1AMERICAN STANDARDwith ducted air handler CM36A3J+TDR | Trane | 2.5 tons29,600 Btu/h · Ducted | 136% | 2.76 | 7.5 | 14.8 | 11.0 | 42,000 | CEE 25CEE 26XcelES CC | 1,188 | 217155224 | Ducted, 2.5–3 tons1,876 models | 100% |
| 13BOVA-60MTB-M19EBOSCHwith ducted air handler AE*L+DM59A4Z+TXV+TDR | Bosch | 3.5 tons43,500 Btu/h · Ducted | 127% | 2.46 | 9.0 | 17.5 | 10.5 | 59,500 | CEE 25CEE 26CEE AdvXcelDOEES CC | 160 | 218693509 | Ducted, 3.5–4.5 tons2,203 models | 100% |
| 14AOUH42KUAH1FUJITSU · AIRSTAGE H-serieswith ductless indoor unit AUUH42KUAS | Fujitsu | 3.5 tons42,000 Btu/h · Non-ducted | 102% | 2.02 | 10.6 | 22.0 | 13.0 | 48,000 | CEE 25CEE 26XcelES CC | 2 | 217895710 | Non-ducted, 3.5–4.5 tons568 models | 100% |
| 15MUZ-FX06NLHZ***Mitsubishi Electric · M-Serieswith ductless indoor unit MSZ-FX06NLAlso listed as MUZ-FX06NLHZ2 | Mitsubishi Electric | 0.5 tons6,000 Btu/h · Non-ducted | 140% | 2.38 | 13.0 | 35.0 | 21.5 | 12,600 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 215611124 | Non-ducted, up to 1.5 tons3,410 models | 99% |
| 16AM060FCMDCG1SAMSUNG · DVM S Mini | Samsung | 5 tons60,000 Btu/h · Ducted | 85% | 2.04 | 10.5 | 19.0 | 11.7 | 56,250 | CEE 25CEE 26XcelES CC | 3 | 216016316 | Ducted, 5 tons and up302 models | 99% |
| 17GK-H02TC/NHA-D(U)GREE · DC inverter rooftop unitAlso sold as Ac Pro PKHP-X-024VBC, Tosot TK-H02TC/NHA-D(U) | Gree | 2 tons24,000 Btu/h · Ducted | 126% | 2.05 | 8.8 | 18.0 | 11.7 | 30,300 | CEE 25CEE 26XcelES CC | 1 | 216763049 | Ducted, 2 tons1,133 models | 99% |
| 18MDPH18024DMRCOOL · Universal DC Inverter Packaged Unit | MRCOOL | 2 tons24,000 Btu/h · Ducted | 126% | 2.05 | 8.8 | 18.0 | 11.7 | 30,300 | CEE 25CEE 26XcelES CC | 1 | 217905218 | Ducted, 2 tons1,133 models | 99% |
| 19RZA30AAVJU*DAIKINwith ductless indoor unit FCA30A*VJU | Daikin | 2.5 tons30,000 Btu/h · Non-ducted | 109% | 1.92 | 10.1 | 21.0 | 13.2 | 37,000 | CEE 25CEE 26Xcel | 3 | 217175210 | Non-ducted, 2.5–3 tons1,054 models | 99% |
| 20NAZ17V6022A1Navien, Inc.with indoor coil HE37*60+TXV and furnace NPF700-100H5CH | Navien | 4 tons50,500 Btu/h · Ducted | 114% | 2.00 | 8.5 | 14.5 | 8.5 | 41,000 | CEE 25CEE 26Xcel | 52 | 218694675 | Ducted, 3.5–4.5 tons2,203 models | 100% |
| 21UXH48-60MSK3IHFrigidairewith ducted air handler D(A,C,E)60C4D+TDR | Nortek Global HVAC | 4 tons46,000 Btu/h · Ducted | 114% | 1.80 | 8.9 | 16.0 | 11.0 | 40,000 | CEE 25CEE 26CEE AdvXcelDOEES CC | 14 | 217754375 | Ducted, 3.5–4.5 tons2,203 models | 99% |
| 22DRA1H09S2ADurastar · DRA Serieswith ductless indoor unit DRAS09F2A | Durastar | 1 ton9,000 Btu/h · Non-ducted | 126% | 1.84 | 10.9 | 27.2 | 15.1 | 11,300 | CEE 25CEE 26XcelES CC | 7 | 215359248 | Non-ducted, up to 1.5 tons3,410 models | 98% |
| 23BZ33-HYP09OUT2-454-G3-PBreeze33 · BZ33 Serieswith ductless indoor unit BZ33-ICM09-454-G3-P | Breeze33 | 1 ton9,000 Btu/h · Non-ducted | 126% | 1.84 | 10.9 | 27.2 | 15.1 | 11,300 | CEE 25CEE 26XcelES CC | 5 | 215449779 | Non-ducted, up to 1.5 tons3,410 models | 98% |
| 24AM3-H24/2DR3BAUX · C-SeriesAlso listed as ASUM24HPMULO | AUX | 2 tons24,000 Btu/h · Non-ducted | 108% | 2.10 | 10.5 | 24.0 | 13.0 | 26,000 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 214097943 | Non-ducted, 2 tons884 models | 98% |
| 25NS21H24MA5-**AGEwith indoor coil D(A,C,E)24C3Z+TXV+TDR and furnace NF96U070S3B | GE Appliances | 2 tons21,400 Btu/h · Ducted | 109% | 2.73 | 9.5 | 19.0 | 12.5 | 25,600 | CEE 25CEE 26CEE AdvXcelDOEES CC | 96 | 218792657 | Ducted, 2 tons1,133 models | 98% |
Download CSV of the Capacity retention at 5°F leaderboardThis leaderboard with each model’s peer percentile.
Typical capacity retention at 5°F by size and duct type
| Peer group | Models | Median Cap. 5/47 |
|---|---|---|
| Ducted, up to 1.5 tons | 1,827 | 74% |
| Ducted, 2 tons | 1,152 | 75% |
| Ducted, 2.5–3 tons | 2,198 | 70% |
| Ducted, 3.5–4.5 tons | 2,607 | 71% |
| Ducted, 5 tons and up | 458 | 53% |
| Non-ducted, up to 1.5 tons | 3,568 | 76% |
| Non-ducted, 2 tons | 903 | 74% |
| Non-ducted, 2.5–3 tons | 1,140 | 74% |
| Non-ducted, 3.5–4.5 tons | 570 | 81% |
| Non-ducted, 5 tons and up | 85 | 65% |