- Insights
- Leaders
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Ranked by Heating capacity at 5°F only, for their size and type
Maximum heating output at 5°F outdoor temperature. This board ranks by that one rating; it is not the overall cold-climate verdict, which is the cold-climate board. Small units rate higher than large ones and ductless units higher than ducted ones, so this board does not rank raw numbers across sizes. Each model is ranked by the share of comparable models (same size and duct type) it beats, one model per manufacturer. Only manufacturers with a QMID (IRS Qualified Manufacturer ID) on file are ranked.
New to heat pump ratings? The Simple view explains them in plain words →
LeaderboardsData as of updated · sources
Top 25 ranked by Heating capacity at 5°F only, against their peers
- All models of the group (shape)
- Leaderboard model
- Median and middle 50% / 80%
Show the data as a table
| Peer group | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 1,783 | 6,200 Btu/h | 6,500 Btu/h | 8,900 Btu/h | 13,600 Btu/h | 18,000 Btu/h |
| Ducted, 2 tons | 1,090 | 10,090 Btu/h | 14,200 Btu/h | 18,800 Btu/h | 21,200 Btu/h | 24,000 Btu/h |
| Ducted, 2.5–3 tons | 1,911 | 13,800 Btu/h | 17,600 Btu/h | 24,400 Btu/h | 30,000 Btu/h | 37,000 Btu/h |
| Ducted, 3.5–4.5 tons | 2,228 | 18,800 Btu/h | 24,400 Btu/h | 35,200 Btu/h | 41,500 Btu/h | 48,000 Btu/h |
| Ducted, 5 tons and up | 320 | 23,800 Btu/h | 25,000 Btu/h | 30,200 Btu/h | 40,000 Btu/h | 42,500 Btu/h |
| Non-ducted, up to 1.5 tons | 3,402 | 7,000 Btu/h | 7,700 Btu/h | 9,300 Btu/h | 13,100 Btu/h | 17,500 Btu/h |
| Non-ducted, 2 tons | 863 | 14,000 Btu/h | 16,400 Btu/h | 18,600 Btu/h | 21,600 Btu/h | 24,000 Btu/h |
| Non-ducted, 2.5–3 tons | 1,107 | 19,800 Btu/h | 22,000 Btu/h | 26,000 Btu/h | 32,000 Btu/h | 36,000 Btu/h |
| Non-ducted, 3.5–4.5 tons | 569 | 31,000 Btu/h | 36,000 Btu/h | 39,500 Btu/h | 47,500 Btu/h | 48,000 Btu/h |
| Non-ducted, 5 tons and up | 85 | 38,000 Btu/h | 38,000 Btu/h | 39,000 Btu/h | 46,500 Btu/h | 54,900 Btu/h |
Source: AHRI Directory · as of
| # · Outdoor model | Manufacturer | Size · type | Btu/h @5°F | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Beats |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1AC024DXSCCGSAMSUNG · Duct S (HSP) Premium (CAC)with ductless indoor unit AC024DNHDCG | Samsung | 2 tons23,000 Btu/h · Non-ducted | 54,000 | 1.80 | — | 9.5 | 18.0 | 12.0 | CEE 25CEE 26XcelES CC | 5 | 215220731 | Non-ducted, 2 tons863 models | 100% |
| 2MMLD024S6S-1PLENNOX · MMLD Mini-Splitwith ductless indoor unit MDDD024S6-1P | Lennox | 2 tons23,000 Btu/h · Non-ducted | 54,000 | 1.80 | — | 9.5 | 18.0 | 12.0 | CEE 25CEE 26XcelES CC | 3 | 215810029 | Non-ducted, 2 tons863 models | 100% |
| 3AVW-60F3DAH2Hisense | Hisense | 5 tons60,000 Btu/h · Ducted | 63,000 | 2.10 | 100% | 10.1 | 17.0 | 10.5 | CEE 25CEE 26CEE AdvXcelDOE | 3 | 216618253 | Ducted, 5 tons and up317 models | 100% |
| 4CHV6-RS60URBMHHCooper & Hunter | Cooper&Hunter | 5 tons60,000 Btu/h · Ducted | 63,000 | 2.10 | 100% | 10.1 | 17.0 | 10.5 | CEE 25CEE 26CEE AdvXcelDOE | 3 | 217026558 | Ducted, 5 tons and up317 models | 100% |
| 5MUZ-FX24NLHZ***Mitsubishi Electric · M-Serieswith ductless indoor unit MSZ-FX24NLAlso listed as MUZ-FX24NLHZ2 | Mitsubishi Electric | 1.5 tons20,800 Btu/h · Non-ducted | 26,600 | 2.04 | 134% | 10.5 | 23.5 | 13.4 | CEE 25CEE 26XcelES CC | 1 | 215912359 | Non-ducted, up to 1.5 tons3,404 models | 100% |
| 65TWV0X24A1TRANEwith indoor coil D(A,C,E)30A4J+TDR and furnace *DHMB060CCV3+LRP | Trane | 1.5 tons19,500 Btu/h · Ducted | 27,200 | 2.90 | 118% | 10.0 | 20.7 | 11.2 | CEE 25CEE 26CEE AdvXcelDOEES CC | 185 | 216794229 | Ducted, up to 1.5 tons1,778 models | 100% |
| 7AOUH18KZAH1FUJITSU · AIRSTAGE H-Serieswith ductless indoor unit ASUH18KZAS | Fujitsu | 1.5 tons18,000 Btu/h · Non-ducted | 25,400 | 2.02 | 118% | 12.5 | 25.5 | 14.0 | CEE 25CEE 26XcelES CC | 2 | 215647921 | Non-ducted, up to 1.5 tons3,404 models | 100% |
| 8KUSXA181ALG · KUSXA181Awith ducted air handler KNSLA181A | LG | 1.5 tons18,000 Btu/h · Ducted | 25,000 | 2.00 | 125% | 10.0 | 18.0 | 13.5 | CEE 25CEE 26XcelES CC | 47 | 215588567 | Ducted, up to 1.5 tons1,778 models | 100% |
| 9RP15AY30AJ2NRHEEMwith ducted air handler L(E,G)M36AJ | Rheem | 2 tons26,400 Btu/h · Ducted | 35,800 | 2.63 | 128% | 7.8 | 15.2 | 11.7 | Xcel | 627 | 218426824 | Ducted, 2 tons1,048 models | 100% |
| 10YRACXJ18WHAAYORK · Y800with ductless indoor unit YRAKXJ18PHAAAlso listed as YRACXJ18WHBA | York | 1.5 tons18,000 Btu/h · Non-ducted | 23,000 | 1.98 | 128% | 11.5 | 21.5 | 14.0 | CEE 25CEE 26XcelES CC | 1 | 218037194 | Non-ducted, up to 1.5 tons3,404 models | 100% |
| 11BOVA-60MTB-M19EBOSCHwith ducted air handler AE*L+DM60A4Z+TXV+TDR | Bosch | 4 tons47,000 Btu/h · Ducted | 64,000 | 2.42 | 121% | 9.0 | 18.5 | 11.2 | CEE 25CEE 26CEE AdvXcelDOEES CC | 160 | 218693517 | Ducted, 3.5–4.5 tons2,236 models | 100% |
| 12H5H0V60*K*AAA*HEILwith indoor coil D(A,C,E)61A3J+TDR and furnace *97CMN0602120B | Carrier | 4 tons50,000 Btu/h · Ducted | 61,000 | 2.29 | 102% | 8.1 | 17.5 | 7.9 | CEE 25CEE 26CEE AdvDOEES CC | 575 | 218372785 | Ducted, 3.5–4.5 tons2,236 models | 100% |
| 13MOVA-60HDN10-M20GMIDEA · X30H-LGWPwith ducted air handler MVME60C2MN10TAAlso listed as MOVC-60HDN10-M20G | Midea | 4.5 tons53,500 Btu/h · Ducted | 55,000 | 2.10 | 100% | 10.0 | 19.0 | 11.7 | CEE 25CEE 26CEE AdvXcelDOEES CC | 59 | 214814477 | Ducted, 3.5–4.5 tons2,236 models | 100% |
| 14BMS1826SHYCBLUERIDGE · BMS Serieswith ductless indoor unit BMS1826SHYWAlso listed as BXS6A18UC0 | BlueRidge | 1.5 tons18,000 Btu/h · Non-ducted | 22,600 | 2.34 | 113% | — | 25.6 | 15.0 | XcelES CC | 1 | 215853910 | Non-ducted, up to 1.5 tons3,404 models | 99% |
| 15SENE-18EL-IHHSENVILLE · SENE Serieswith ductless indoor unit SENE-18EL-OHAlso listed as SENE-18EL-OH | Senville | 1.5 tons18,000 Btu/h · Non-ducted | 22,600 | 2.34 | 113% | — | 25.6 | 15.0 | XcelES CC | 1 | 217607369 | Non-ducted, up to 1.5 tons3,404 models | 99% |
| 16AM2-H18/2DR3BAUX · C-SeriesAlso listed as ASUM18HPMULO | AUX | 1.5 tons18,000 Btu/h · Non-ducted | 21,800 | 2.00 | 121% | 11.0 | 23.3 | 12.5 | CEE 25CEE 26XcelES CC | 1 | 214097940 | Non-ducted, up to 1.5 tons3,404 models | 99% |
| 17RXM18WVJU*DAIKINwith ductless indoor unit FTXM18WVJU | Daikin | 1.5 tons18,000 Btu/h · Non-ducted | 21,600 | 1.80 | 100% | 10.0 | 22.7 | 12.5 | CEE 25CEE 26Xcel | 2 | 212494259 | Non-ducted, up to 1.5 tons3,404 models | 99% |
| 182G20ED2BE**GE Appliances · Endure Multi | GE Appliances | 1.5 tons17,000 Btu/h · Ducted | 20,000 | 1.80 | 91% | 10.5 | 17.6 | 10.8 | CEE 25CEE 26XcelES CC | 3 | 217021958 | Ducted, up to 1.5 tons1,778 models | 99% |
| 19GK-H02TC/NHA-D(U)GREE · DC inverter rooftop unitAlso sold as Ac Pro PKHP-X-024VBC, Tosot TK-H02TC/NHA-D(U) | Gree | 2 tons24,000 Btu/h · Ducted | 30,300 | 2.05 | 126% | 8.8 | 18.0 | 11.7 | CEE 25CEE 26XcelES CC | 1 | 216763049 | Ducted, 2 tons1,048 models | 99% |
| 20MDPH18024DMRCOOL · Universal DC Inverter Packaged Unit | MRCOOL | 2 tons24,000 Btu/h · Ducted | 30,300 | 2.05 | 126% | 8.8 | 18.0 | 11.7 | CEE 25CEE 26XcelES CC | 1 | 217905218 | Ducted, 2 tons1,048 models | 99% |
| 21048-TPH-MODU-1D3DELLA · TPH | Della | 1.5 tons20,000 Btu/h · Non-ducted | 19,800 | 2.00 | 99% | 10.0 | 27.0 | 15.0 | CEE 25CEE 26XcelES CC | 2 | 218471007 | Non-ducted, up to 1.5 tons3,404 models | 98% |
| 22SHV18H2BAINNOVAIR · SWV Serieswith ducted air handler SWV18BDA | Innovair | 1.5 tons18,000 Btu/h · Ducted | 19,600 | 2.10 | 103% | 10.8 | 19.3 | 12.1 | CEE 25CEE 26CEE AdvXcelDOEES CC | 9 | 216027612 | Ducted, up to 1.5 tons1,778 models | 98% |
| 23DRA1H18S2ADURASTARwith ducted air handler DRUF1820S2A | Durastar | 1.5 tons18,000 Btu/h · Ducted | 19,600 | 2.10 | 103% | 10.8 | 19.3 | 12.1 | CEE 25CEE 26CEE AdvXcelDOEES CC | 9 | 217285070 | Ducted, up to 1.5 tons1,778 models | 98% |
| 24BZ33-HYP36OUT2-454-G3-PBreeze33 · BZ33 Serieswith ductless indoor unit BZ33-IFCM36-454-G3-P | Breeze33 | 3 tons36,400 Btu/h · Non-ducted | 39,500 | 2.02 | 104% | 10.8 | 20.0 | 12.0 | CEE 25CEE 26XcelES CC | 4 | 215449784 | Non-ducted, 2.5–3 tons1,107 models | 98% |
| 25UXH48-60MSK3IHGibson · E Serieswith ducted air handler UMD60MSK3IH | Nortek Global HVAC | 4.5 tons53,000 Btu/h · Ducted | 54,000 | 2.10 | 100% | 10.5 | 18.5 | 11.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 14 | 217138209 | Ducted, 3.5–4.5 tons2,236 models | 98% |
Download CSV of the Heating capacity at 5°F leaderboardThis leaderboard with each model’s peer percentile.
Typical heating capacity at 5°F by size and duct type
| Peer group | Models | Median Btu/h @5°F |
|---|---|---|
| Ducted, up to 1.5 tons | 1,827 | 8,900 Btu/h |
| Ducted, 2 tons | 1,152 | 18,800 Btu/h |
| Ducted, 2.5–3 tons | 2,198 | 24,400 Btu/h |
| Ducted, 3.5–4.5 tons | 2,607 | 35,200 Btu/h |
| Ducted, 5 tons and up | 458 | 30,200 Btu/h |
| Non-ducted, up to 1.5 tons | 3,568 | 9,300 Btu/h |
| Non-ducted, 2 tons | 903 | 18,600 Btu/h |
| Non-ducted, 2.5–3 tons | 1,140 | 26,000 Btu/h |
| Non-ducted, 3.5–4.5 tons | 570 | 39,500 Btu/h |