Skip to content

DOE Cold Climate Heat Pump Challenge: 338 qualifying heat pumps

Rating thresholds from the DOE Residential Cold Climate Heat Pump Technology Challenge.

Simple view, for homeowners: top picks by size and what each rating measures →

U.S. Department of EnergyData as of updated · sources

Share of models
2.5%
Qualifying models
338
Qualifying certifications
1,206
Paths
1

Criteria

A model qualifies when one certification meets every value in this row.
PathHSPF2COP@5°FCap. 5/47
Challenge specification≥ 8.5≥ 2.1≥ 100%

Source: U.S. Department of Energy

Where the thresholds fall

Every model's representative certification on each rating DOE CCHP checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F12,514 rated models · median 2.0030% of rated models reach 2.1 on this rating alone.
+39 above13 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4013
1.40 to under 1.5081
1.50 to under 1.60190
1.60 to under 1.70389
1.70 to under 1.801,291
1.80 to under 1.902,581
1.90 to under 2.001,532
2.00 to under 2.102,675
2.10 to under 2.201,457
2.20 to under 2.30883
2.30 to under 2.40548
2.40 to under 2.50284
2.50 to under 2.60246
2.60 to under 2.70139
2.70 to under 2.8081
2.80 to under 2.9052
2.90 to under 3.0033
3.00 and above39
Baseline: median2.00
Baseline: DOE CCHP 2.12.10

Source: AHRI Directory · as of

Capacity retention at 5°F12,433 rated models · median 72%10% of rated models reach 100% on this rating alone.
+59 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%29
35 to under 40%340
40 to under 45%483
45 to under 50%574
50 to under 55%704
55 to under 60%666
60 to under 65%782
65 to under 70%892
70 to under 75%2,697
75 to under 80%1,230
80 to under 85%910
85 to under 90%410
90 to under 95%798
95 to under 100%623
100 to under 105%825
105 to under 110%148
110 to under 115%151
115 to under 120%23
120 to under 125%38
125% and above59
Baseline: median72%
Baseline: DOE CCHP 100%100%

Source: AHRI Directory · as of

HSPF213,595 rated models · median 9.068% of rated models reach 8.5 on this rating alone.
+63 above43 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.543
6.5 to under 6.81,016
6.8 to under 7.069
7.0 to under 7.3568
7.3 to under 7.518
7.5 to under 7.81,201
7.8 to under 8.0382
8.0 to under 8.3838
8.3 to under 8.5188
8.5 to under 8.81,687
8.8 to under 9.0198
9.0 to under 9.31,671
9.3 to under 9.5142
9.5 to under 9.81,624
9.8 to under 10.0312
10.0 to under 10.31,826
10.3 to under 10.5237
10.5 to under 10.8656
10.8 to under 11.082
11.0 to under 11.3316
11.3 to under 11.560
11.5 to under 11.8131
11.8 to under 12.021
12.0 to under 12.330
12.3 to under 12.52
12.5 to under 12.896
12.8 to under 13.01
13.0 to under 13.324
13.3 to under 13.510
13.5 to under 13.846
13.8 to under 14.037
14.0 and above63
Baseline: median9.0
Baseline: DOE CCHP 8.58.5

Source: AHRI Directory · as of

Qualification by size

Share of models meeting DOE CCHP, by size
Show the data as a table
Share of models meeting DOE CCHP, by size
GroupQualifying share
Up to 1.5 tons3.3% · 180 of 5,427
2 tons1.9% · 37 of 1,941
2.5 to 3 tons2.1% · 63 of 2,942
3.5 to 4.5 tons2% · 56 of 2,834
5 tons and up0.4% · 2 of 475

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted1.8%117 / 6,438
Non-ducted2%98 / 4,861
Ducted and non-ducted5.3%123 / 2,320

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree40 of 7295.5%
Midea19 of 5553.4%
York18 of 2397.5%
Mitsubishi Electric16 of 15610.3%
Fujitsu14 of 1807.8%
LG13 of 10812%
Hisense12 of 1687.1%
HITACHI11 of 6616.7%
Lennox9 of 3412.6%
Trane9 of 3702.4%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting DOE Cold Climate Heat Pump Challenge, page 3 of 14
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
51H5H0V60*K*AAA*HEILwith indoor coil D(A,C,E)61A3J+TDR and furnace *80CSU0802120BCarrier4.5 tons51,500 Btu/h · Ducted2.39102%8.118.5CEE 25CEE 26CEE AdvDOEES CC593218372772
52W5HD606K1X1AGrandaire · W5H Serieswith ducted air handler W5GLW06K1AAACarrier0.5 tons6,500 Btu/h · Ducted and non-ducted2.4198%13.821.4CEE 25CEE 26CEE AdvXcelDOEES CC3218854029
53A-VHP06SA-1CENTURY · A Serieswith ductless indoor unit B-VHP061A-1Century0.5 tons6,500 Btu/h · Non-ducted2.40109%12.022.0CEE 25CEE 26CEE AdvXcelDOEES CC2217482454
54A-VXP18SA-1CENTURY · A Serieswith ducted air handler WXP18SACentury1.5 tons18,000 Btu/h · Ducted2.10103%10.819.3CEE 25CEE 26CEE AdvXcelDOEES CC4217482412
55GMRSHC36AS4CLASSIC · M-SeriesCLASSIC3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.10100%10.021.0CEE 25CEE 26CEE AdvXcelDOEES CC3217284815
56CHF3-06CD(O)COMFORTSTAR · CHF Serieswith ducted air handler CPA3-06CD(I)COMFORTSTAR0.5 tons6,500 Btu/h · Ducted and non-ducted2.4198%13.821.4CEE 25CEE 26CEE AdvXcelDOEES CC3217138375
57CPH3-18CD(O)COMFORTSTAR · CPH Serieswith ducted air handler SEF3 - 18 - SG3COMFORTSTAR1.5 tons18,000 Btu/h · Ducted2.12103%10.119.0CEE 25CEE 26CEE AdvXcelDOEES CC3217730322
58CH-PQ18-230VOCooper&Hunter · CH Serieswith ducted air handler CH-PQ18AHUCooper&Hunter1.5 tons18,000 Btu/h · Ducted2.12103%10.119.0CEE 25CEE 26CEE AdvXcelDOEES CC8215864120
59CH-RHP06F9-230VOCooper&Hunter · CH Serieswith ducted air handler CH-RS06MDT-MSCooper&Hunter0.5 tons6,500 Btu/h · Ducted and non-ducted2.4198%13.821.4CEE 25CEE 26CEE AdvXcelDOEES CC7215864212
60CHV6-RS36URBMHHCooper & HunterCooper&Hunter3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.45100%10.823.0CEE 25CEE 26CEE AdvXcelDOE3217026553
61CHV6-RS48URBMHHCooper & HunterCooper&Hunter4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.40100%10.822.0CEE 25CEE 26CEE AdvXcelDOE3217026556
62CHV6-RS60URBMHHCooper & HunterCooper&Hunter5 tons60,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.30100%11.021.5CEE 25CEE 26CEE AdvXcelDOE3217026559
63CCOXHBSZ06HPCustom Comfort · COOX Serieswith ducted air handler CCOXHBSD06Custom Comfort0.5 tons6,500 Btu/h · Ducted and non-ducted2.4198%13.821.4CEE 25CEE 26CEE AdvXcelDOEES CC3215745983
64AZV9SA241CA*AMANA · AZV9SAwith ducted air handler CAHEA3630C3A*+MBVK16CH*X00ADaikin2 tons24,000 Btu/h · Ducted2.40100%10.021.0CEE 25CEE 26CEE AdvXcelDOEES CC47216699793
65AZV9SA361CA*AMANA · AZV9SAwith ducted air handler CAHEA3630C3A*+MBVK16CH*X00ADaikin3 tons34,200 Btu/h · Ducted2.40100%10.021.0CEE 25CEE 26CEE AdvXcelDOEES CC35216699794
66DH9VSA241CA*DAIKIN · DH9VSAwith ducted air handler CAHEA3630C3A*+MBVK16CH*X00ADaikin2 tons24,000 Btu/h · Ducted2.40100%10.021.0CEE 25CEE 26CEE AdvXcelDOEES CC47216699791
67DH9VSA361CA*DAIKIN · DH9VSAwith ducted air handler CAHEA3630C3A*+MBVK16CH*X00ADaikin3 tons34,200 Btu/h · Ducted2.40100%10.021.0CEE 25CEE 26CEE AdvXcelDOEES CC35216699792
68GZV9SA241CA*GOODMAN · GZV9SAwith ducted air handler CAHEA3630C3A*+MBVK16CH*X00ADaikin2 tons24,000 Btu/h · Ducted2.40100%10.021.0CEE 25CEE 26CEE AdvXcelDOEES CC45216699795
69GZV9SA361CA*GOODMAN · GZV9SAwith ducted air handler CAHEA3630C3A*+MBVK16CH*X00ADaikin3 tons34,200 Btu/h · Ducted2.40100%10.021.0CEE 25CEE 26CEE AdvXcelDOEES CC33216699796
70MST183G32MHAAGOODMAN · MST SeriesDaikin1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.10100%11.027.0CEE 25CEE 26CEE AdvXcelDOEES CC3218083366
71MST273G32MHAAGOODMAN · MST SeriesDaikin2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.2099%10.524.0CEE 25CEE 26CEE AdvXcelDOEES CC3218083369
72RZA18AAVJU*DAIKINwith ductless indoor unit FCA18A*VJUDaikin1.5 tons18,000 Btu/h · Ducted and non-ducted2.12100%9.219.5CEE 25CEE 26CEE AdvXcelDOE4217175208
73DIRM4-06HXPRO28-1ZDIRECT AIR · DIR Serieswith ductless indoor unit DIRM4-06HP-WMDIRECT AIR0.5 tons6,000 Btu/h · Non-ducted2.40110%14.825.5CEE 25CEE 26CEE AdvXcelDOEES CC1216571371
74ACIQ-60-HP32DIYCOOL · R32 Extreme Heat Unitarywith ducted air handler ACIQ-60-AH32DIYCOOL4.5 tons53,000 Btu/h · Ducted2.10100%10.518.2CEE 25CEE 26CEE AdvXcelDOEES CC1215387245
75DRA1H06S2ADurastar · DRA Serieswith ducted air handler DRADL0612F2ADurastar0.5 tons6,500 Btu/h · Ducted and non-ducted2.4198%13.821.4CEE 25CEE 26CEE AdvXcelDOEES CC3215359244

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter